NextSDS Logo
Safety Data Sheet EN

Polyethyleneimine, linear, M.W. 25,000

CAS 9002-98-6

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Polyethyleneimine, linear, M.W. 25,000
Product Code
43896

Regulatory Identifiers

CAS Number
9002-98-6 Check regulations →

Identified Uses

Laboratory chemicals.

Uses advised against

Food, drug, pesticide or biocidal product use.

Manufacturers & Suppliers

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc. logo

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc.

manufacturer

30 Bond Street, Ward Hill, MA 01835-8099

800-343-0660

http://www.alfa.com

Emergency Contacts

Emergency Contact

(800) 343-0660

Monday-Friday, 8am-7pm EST

Carechem 24

(866) 928-0789

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Polyethyleneimine 9002-98-6 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.

Ingestion

Do NOT induce vomiting.

Medical Treatment

Treat symptomatically

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Unsuitable media

No information available

Specific hazards

Keep product and empty container away from heat and sources of ignition.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not flush into surface water or sanitary sewer system.

Cleanup methods

No information available.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure adequate ventilation.

Storage

Keep containers tightly closed in a dry, cool and well-ventilated place.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

None under normal use conditions.

Hands

Wear appropriate protective gloves

Eyes

Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166.

Respiratory

No protective equipment is needed under normal use conditions.

Skin/Body

Wear appropriate protective clothing to prevent skin exposure.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Powder Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
---
Colour Intensity
---
Form
---
Odor
---
Odor Threshold
---
Ph
---
Melting Point
59 - 60 °C / 138.2 - 140 °F
Boiling Point
---
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

None known, based on information available

Hazardous reactions

None under normal processing. Hazardous polymerization does not occur.

Avoid

Incompatible products.

Incompatible

Strong oxidizing agents

Decomposition

Carbon monoxide (CO), Carbon dioxide (CO₂)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Ecotoxicity

Toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment. The product contains following substances which are hazardous for the environment.

The product is toxic to aquatic organisms and may cause long-term adverse effects in the aquatic environment.

Persistence and Degradability

No information available

Bioaccumulation/ Accumulation

No information available.

Mobility

No information available.

Results of PBT and vPvB assessment

No information available.

Endocrine disrupting properties

No information available.

Other adverse effects

No information available.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN3077
Shipping Name
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S.
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Polyethyleneimine, linear, M.W. 25,000?

The signal word is no signal word.

What is the physical form of Polyethyleneimine, linear, M.W. 25,000?

Polyethyleneimine, linear, M.W. 25,000 is a powder solid .

What is Polyethyleneimine, linear, M.W. 25,000 used for?

Laboratory chemicals.

What is the melting point of Polyethyleneimine, linear, M.W. 25,000?

The melting point is 59 - 60 °C / 138.2 - 140 °F .