NextSDS Logo
Safety Data Sheet EN

TWEEN® 20

CAS 9005-64-5

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
TWEEN® 20
Product Code
P1379

Regulatory Identifiers

CAS Number
9005-64-5 Check regulations →

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

S

Sigma-Aldrich Chemie GmbH

manufacturer

Eschenstrasse 5, D-82024 TAUFKIRCHEN

+49 (0)89 6513-1130

Emergency Contacts

CHEMTREC Deutschland

0800 181 7059

CHEMTREC weltweit

+49 (0)696 43508409

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

No components need to be disclosed according to the applicable regulations.

Chemical Name CAS Number Concentration Hazardous
Polyoxyethylenesorbitan monolaurate EC: 500-018-3 9005-64-5 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

rinse out with plenty of water. Remove contact lenses.

Ingestion

make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water Foam Carbon dioxide (CO₂) Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Carbon oxides. Combustible. Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating. Development of hazardous combustion gases or vapours possible in the event of fire.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not breathe vapors, aerosols. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up with liquid-absorbent material (e.g. Chemizorb®). Clean up affected area.

Materials: liquid-absorbent material (e.g. Chemizorb®)

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: Dermatril® (KCL 740 / Aldrich Z677272, Size M). Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: Dermatril® (KCL 740 / Aldrich Z677272, Size M). data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374. If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the EC approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

Not required; except in case of aerosol formation.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
viscous
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
yellow
Colour Intensity
---
Form
---
Odor
odorless
Odor Threshold
---
Ph
7
Melting Point
No data available
Boiling Point
> 100 °C
Flash Point
275 °C at ca.1.013 hPa - Pensky-Martens closed cup - DIN 51758
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
< 1,4 hPa at 20 °C
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1,100 g/cm3 at 25 °C
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
0,0002 g/l at 20 °C - OECD Test Guideline 105
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
ca.400 mPa.s at 25 °C
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical.

Hazardous reactions

Violent reactions possible with: Strong oxidizing agents

Avoid

Strong heating.

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Toxicity to fish: static test LL50 - Danio rerio (zebra fish) - > 100 mg/l - 96 h (OECD Test Guideline 203)

12.1 Toxicity

Toxicity to daphnia and other aquatic invertebrates: EC50 - Daphnia - > 10 mg/l - 48 h Remarks: (above the solubility limit in the test medium) (Lit.)

12.1 Toxicity

Toxicity to bacteria: microtox test EC50 - Bacteria - 146 - 774 mg/l - 5 min Remarks: (Lit.)

12.2 Persistence and degradability

Biodegradability: aerobic - Exposure time 28 d Result: > 60 % - Readily biodegradable. (OECD Test Guideline 301F)

12.3 Bioaccumulative potential

No data available

12.4 Mobility in soil

No data available

12.5 Results of PBT and vPvB assessment

This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

12.6 Endocrine disrupting properties

Assessment: The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.

The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.

12.7 Other adverse effects

Discharge into the environment must be avoided.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

No data available

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This material safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for TWEEN® 20?

The signal word is no signal word.

What is the physical form of TWEEN® 20?

TWEEN® 20 is a viscous with yellow color. It has odorless odor.

What is TWEEN® 20 used for?

Laboratory chemicals, Manufacture of substances

What is the melting point of TWEEN® 20?

The melting point is No data available and the boiling point is > 100 °C.