NextSDS Logo
Safety Data Sheet EN

Spent Copper/Aluminum Catalyst

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Spent Copper/Aluminum Catalyst
Chemical Name
Copper carbonate

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Use only as an industrial chemical.

Manufacturers & Suppliers

S

ShoreMet LLC

manufacturer

3601 Enterprise Ave, Valparaiso, IN 46383

(219) 390-3336 x100

Emergency Contacts

CHEMTREC

(800) 424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Acute Tox. Cat. 4 H302

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H302 Harmful if swallowed.

Precautionary Statements

P264 Wash skin thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P501 Dispose of contents/container to hazardous or special waste collection point, in accordance with local, regional, national and/or international regulation.
IF SWALLOWED: Call a POISON CENTER or doctor if you feel unwell. Rinse mouth.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Basic copper carbonate 12069-69-1 15 - 60% No
Copper sulfide 22205-45-4 10 - 40% No
Aluminum oxide 1344-28-1 10 - 40% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Immediately remove the affected person to fresh air. Seek immediate medical attention. Do NOT perform mouth-to-mouth resuscitation unless a pocket mask equipped with a one-way valve or another proper respiratory medical device is available.

Symptoms: Dry/sore throat. Irritation of the respiratory tract and nasal mucous membranes.

Skin contact

For skin contact, wash immediately with soap and water. Immediately take off all contaminated clothing. Seek immediate medical attention if irritation develops or persist.

Symptoms: With continuous/repeated exposure/contact, skin rash/inflammation.

Eye contact

Immediately flush eyes with water for at least 15 minutes, while holding eyelids open. Remove contact lenses, if present and easy to do. Seek medical attention if irritation persist.

Symptoms: Slight irritation.

Ingestion

If the material is swallowed, get immediate medical attention or advice—do not induce vomiting. Have victim rinse mouth thoroughly with water, if conscious. Give one to two glasses of water or milk. Never give anything by mouth to an unconscious victim. Do not use mouth-to-mouth if victim has ingested the substance. Induce artificial respiration with a proper respiratory medical device.

Symptoms: Gastrointestinal complaints, vomiting, abdominal pain and/or diarrhea.

Immediate Medical Attention

Depending on the victim’s condition: doctor or hospital. Seek immediate medical attention if irritation develops or persist (skin). Seek immediate medical attention (inhalation/ingestion).

Medical Treatment

Treat the affected person symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Dry chemical, foam, carbon dioxide, or water spray.

Specific hazards

Material is non-flammable or explosive.

Instructions

Separate from mass. Eliminate oxygen.

Firefighter Protection

Firefighters should wear full protective clothing including self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Stop the flow of material, if this is without risk. Contain spillages and clean-up with vacuum or conventional tools in an attempt to minimize migration use dikes or absorbents. Neutralize with citric acid or other neutralizing agent for basic liquids. Decontaminate the area. Test area with litmus paper to ensure neutralization. Ventilate the contaminated area. Place in a suitable container for recycling or disposal in accordance with local and national waste regulations.

Environmental

Do not allow to enter drains or watercourses. If the product enters drains or sewers, immediately inform the local water company. Where there is contamination of streams, rivers or lakes contact local agency with responsibility for the environment.

Cleanup methods

clean-up with vacuum or conventional tools

Materials: vacuum or conventional tools

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not get this material in your eyes, on your skin or on your clothing. Do not inhale vapors or mists of this product. Use this product with adequate ventilation. Avoid release to the environment. Wash thoroughly after handling. Keep out of reach of children.

Storage

Store in a cool, dry, well-ventilated area. Store away from direct sunlight, or any source of intense heat. Store away from area where freezing is possible.

Hygiene

Wash thoroughly after handling.

Fire prevention

Post warning and “NO SMOKING” signs in storage and use areas, as appropriate.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
black powder
Colour
---
Colour Intensity
---
Form
---
Odor
---
Odor Threshold
---
Ph
6.2-6.8 @ 20°C (68°F)
Melting Point
---
Boiling Point
---
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
Not available
Vapor Density
Not available
Relative Density
4.0 @ 20°C (68°F)
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
Not available
Solubility
---
Partition Coefficient
Not Available
Solubility In Water
Insoluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not available
Kinematic Viscosity
Not available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

This is a stable material at normal conditions.

Hazardous reactions

Not expected to occur.

Avoid

Avoid extremely high or low temperatures, direct sunlight and contact with incompatible materials.

Incompatible

Strong acids.

Decomposition

Decomposition products include copper fumes, copper compounds, and carbon oxides.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Ecotoxicity: No data available.

No data available.

12.2 Persistence and degradability

Persistence: No data available. Degradability: No data available.

No data available.

12.3 Bioaccumulative potential

Bioaccumulative Potential: No data available.

No data available.

12.4 Mobility in soil

Mobility in Soil: No data available.

No data available.

12.5 Results of PBT and vPvB assessment

No data available.

12.6 Endocrine disrupting properties

No data available.

12.7 Other adverse effects

No data available.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

treatment at a permitted facility or as advised by your local hazardous waste regulatory authority

Disposal

This product, if unaltered by use, may be disposed of by treatment at a permitted facility or as advised by your local hazardous waste regulatory authority.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

All components are on the US EPA TSCA Inventory List. All components are on the Canadian Domestic Substances or Non-Domestic Substances Inventory Lists. Listed on the EEC inventory EINECS (European Inventory of Existing Commercial Chemical Substances) substances.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Spent Copper/Aluminum Catalyst?

The signal word is warning.

What is the physical form of Spent Copper/Aluminum Catalyst?

Spent Copper/Aluminum Catalyst is a solid appearing as black powder .

What is Spent Copper/Aluminum Catalyst used for?

Use only as an industrial chemical.

What are the hazard statements for Spent Copper/Aluminum Catalyst?

This substance has 1 hazard statement:

  • H302: Harmful if swallowed.