Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ARCHITECT Anti-HCV Conjugate
- Product Code
- 1L79H
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For In Vitro Diagnostic Use
Manufacturers & Suppliers
Abbott Diagnostics
manufacturer
100 Abbott Park Road, Abbott Park, IL 60064-3500
1-877-4 ABBOTT
Emergency Contacts
CHEMTREC® Emergency Call Center
(800) 424-9300
24 hours/day, 7 days/week
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| polyethylene glycol octylphenyl ether | 9002-93-1 | 1.0626% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove from source of exposure. If irritation or signs of toxicity occur, seek medical attention.
Take off any clothing that the product touched. Rinse skin with running water for 15 to 20 minutes. Seek medical attention if irritation or signs of toxicity occur.
Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists, get medical advice/attention. Wash hands after handling.
Rinse mouth with water. If irritation or signs of toxicity occur, seek medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Dry chemical, carbon dioxide (CO2), water spray or regular foam.
There are no unique chemical or reactivity hazards that would impact firefighting decisions due to the chemicals in this product.
Use firefighting measures that suit the environment.
Firefighter Protection
For large fires, wear appropriate heat- and flame-resistant personal protective equipment and a NFPA/NIOSH approved positive-pressure, self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stop leak if possible. Keep unprotected persons away.
Blot up small volumes of spilled or spattered product with paper towels or similar materials.
Contain larger spills by placing absorbants around the outside edges of the spill. Absorb with any material suitable for water-based liquids - e.g. paper towels, universal sorbents, sand, diatomite, sawdust, etc.
Prevent liquid and vapor from entering sewage system, storm drains, surface waters, and soil.
Clean the affected area.
Materials: warm water and detergent or similar cleansing agent
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes.
Store only in the original container. Store in original packaging. Refer to the package insert or product label for additional information on storage conditions for product quality.
The product is not flammable.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Wear impervious gloves if hand contact with the material is anticipated. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. The glove material must be suitable for use in a microbiological laboratory and have a measured breakthrough time of at least 30 minutes, such as those with a Class 2 protection index per EN374 (or equivalent standard applicable in your region). NOTE: This recommendation applies only to the product stated in this Safety Data Sheet. When dissolving in or mixing with other substances, contact the supplier of approved gloves.
Wear safety glasses or other protective eyewear. If splash potential exists, wear full face shield or goggles.
Normal use and storage of product - respiratory protection is not necessary if room is well ventilated. Small-volume spills (e.g. small enough to clean up with a paper towel or small sorbent pad) - respiratory protection should not be necessary if room is well ventilated. Other unusual conditions (e.g. volume spilled too big to clean up with materials in arm's reach) - Use appropriate NIOSH-approved air-purifying respirator if airborne chemical concentrations may exceed the exposure limit (if any) listed above. Hazardous Materials Emergencies or Firefighting - use NIOSH/NFPA-approved respiratory protection.
Normal use: protect personal clothing from spatters and small spills. Wear a laboratory coat (or other protective clothing required by your institution). Larger spills (e.g. that can saturate cloth): wear appropriate water-repellant covering over clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used and stored according to specifications.
No dangerous reactions known.
No further relevant information available.
No further relevant information available.
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
No further relevant information available.
12.5 Results of PBT and vPvB assessment
The substance is not considered PBT or vPvB.
12.7 Other adverse effects
The product is toxic for aquatic organisms.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose in accordance with federal, state and local regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3082
- Shipping Name
- ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (polyethylene glycol octylphenyl ether)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ARCHITECT Anti-HCV Conjugate?
The signal word is warning.
What is the physical form of ARCHITECT Anti-HCV Conjugate?
ARCHITECT Anti-HCV Conjugate is a liquid with light yellow color. It has odorless odor.
What is ARCHITECT Anti-HCV Conjugate used for?
For In Vitro Diagnostic Use
What are the hazard statements for ARCHITECT Anti-HCV Conjugate?
This substance has 2 hazard statements:
- H319: Causes serious eye irritation.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of ARCHITECT Anti-HCV Conjugate?
The melting point is Not determined and the boiling point is Not determined.