Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- p-Cresol
- Product Code
- W233706
- Chemical Name
- p-Cresol
Regulatory Identifiers
- CAS Number
- 106-44-5 Check regulations →
Identified Uses
Laboratory chemicals, Synthesis of substances
Uses advised against
Not Available
Manufacturers & Suppliers
Sigma-Aldrich Inc.
manufacturer
3050 SPRUCE ST, ST. LOUIS MO 63103, UNITED STATES
+1 314 771-5765
Emergency Contacts
CHEMTREC
800-424-9300
24 Hours/day; 7 Days/week
CHEMTREC
+1-703-527-3887
24 Hours/day; 7 Days/week
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS06
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| p-cresol | 106-44-5 | 90 - 100% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air. Call in physician.
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower. Call a physician immediately.
After eye contact: rinse out with plenty of water. Immediately call in ophthalmologist. Remove contact lenses.
If swallowed: give water to drink (two glasses at most). Seek medical advice immediately. In exceptional cases only, if medical care is not available within one hour, induce vomiting (only in persons who are wide awake and fully conscious), administer activated charcoal (20 - 40 g in a 10% slurry) and consult a doctor as quickly as possible. Do not attempt to neutralise.
Immediate Medical Attention
Call in physician. Call a physician immediately. Immediately call in ophthalmologist. Seek medical advice immediately. consult a doctor as quickly as possible.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water, Foam, Carbon dioxide (CO2), Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Combustible. Vapours are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating. Development of hazardous combustion gases or vapours possible in the event of fire.
Remove container from danger zone and cool with water.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Collect, bind, and pump off spills. Take up carefully. Clean up affected area.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from open flames, hot surfaces and sources of ignition. Take precautionary measures against static discharge.
Tightly closed. Dry. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorised persons.
Keep away from open flames, hot surfaces and sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical. The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.
Violent reactions possible with: Strong oxidizing agents, Nitric acid, fuming sulfuric acid, Aluminium
Strong heating.
No data available
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Ecotoxicity
The substance is harmful to aquatic life with long lasting effects, showing toxicity to fish, daphnia, algae, and microorganisms.
Persistence and degradability
Bioaccumulative potential
Mobility in soil
Results of PBT and vPvB assessment
Endocrine disrupting properties
Other adverse effects
Bioaccumulative potential
Mobility in soil
Other adverse effects
12.7 Other adverse effects
The product does not contain or use Class I or Class II ozone-depleting substances as defined by the U.S. Clean Air Act.
Endocrine disrupting properties
No data available
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Waste material must be disposed of in accordance with the national and local regulations.
Leave chemicals in original containers. No mixing with other waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3455
- Shipping Name
- Cresols, solid
- Transport Class
- 6.1
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for p-Cresol?
The signal word is danger.
What is the physical form of p-Cresol?
p-Cresol is a crystalline appearing as crystalline with colourless color. It has phenol-like odor.
What is p-Cresol used for?
Laboratory chemicals, Synthesis of substances
What are the hazard statements for p-Cresol?
This substance has 4 hazard statements:
- H301: H301 + H311 Toxic if swallowed or in contact with skin.
- H314: H314 Causes severe skin burns and eye damage.
- H401: H401 Toxic to aquatic life.
- H412: H412 Harmful to aquatic life with long lasting effects.
What is the melting point of p-Cresol?
The melting point is 88 - 99 °F / 31 - 37 °C; 90 - 93 °F / 32 - 34 °C; Method: lit. and the boiling point is 396 °F / 202 °C; Method: lit..