Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Caffeine solution
- Product Code
- C-051
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals, Manufacture of substances
Uses advised against
For R&D use only. Not for pharmaceutical, household or other uses.
Manufacturers & Suppliers
Sigma-Aldrich Chemie GmbH
manufacturer
Eschenstrasse 5, D-82024 TAUFKIRCHEN
+49 (0)89 6513-1130
Emergency Contacts
CHEMTREC Deutschland
0800 181 7059
CHEMTREC weltweit
+49 (0)696 43508409
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS06
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Methanol EC: 200-659-6 | 67-56-1 | 90 - 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician.
Flush eyes with water as a precaution.
Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
Immediate Medical Attention
Take victim immediately to hospital.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Carbon oxides
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear respiratory protection. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapors accumulating to form explosive concentrations. Vapors can accumulate in low areas.
Prevent further leakage or spillage if safe to do so.
collect with an electrically protected vacuum cleaner or by wet-brushing and place in container for disposal according to local regulations (see section 13)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes. Avoid inhalation of vapor or mist.
Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Avoid contact with skin, eyes and clothing. Wash hands before breaks and immediately after handling the product.
Keep away from sources of ignition - No smoking.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. Full contact: Material: butyl-rubber, Minimum layer thickness: 0,3 mm, Break through time: 480 min, Material tested: Butoject® (KCL 897 / Aldrich Z677647, Size M). Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,4 mm, Break through time: 30 min, Material tested: Camatril® (KCL 730 / Aldrich Z677442, Size M). data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374. If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the EC approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.
Face shield and safety glasses Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Complete suit protecting against chemicals, Flame retardant antistatic protective clothing., The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
No data available
No data available
Heat, flames and sparks. Extremes of temperature and direct sunlight.
Acids, Oxidizing agents, Alkali metals, Strong oxidizing agents, Strong acids, Acid chlorides, Acid anhydrides, Reducing agents, Strong reducing agents, Phosphorus halides
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
12.6 Endocrine disrupting properties
The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.
12.7 Other adverse effects
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Burn in a chemical incinerator equipped with an afterburner and scrubber but exert extra care in igniting as this material is highly flammable. Offer surplus and non-recyclable solutions to a licensed disposal company.
Burn in a chemical incinerator equipped with an afterburner and scrubber but exert extra care in igniting as this material is highly flammable. Offer surplus and non-recyclable solutions to a licensed disposal company.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1230
- Shipping Name
- METHANOL, SOLUTION
- Transport Class
- 3 (6.1)
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This material safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Caffeine solution?
The signal word is danger.
What is the physical form of Caffeine solution?
Caffeine solution is a liquid with no data available color. It has no data available odor.
What is the solubility of Caffeine solution?
No data available
What is Caffeine solution used for?
Laboratory chemicals, Manufacture of substances
What are the hazard statements for Caffeine solution?
This substance has 3 hazard statements:
- H225: Highly flammable liquid and vapor.
- H301 + H311 + H331: Toxic if swallowed, in contact with skin or if inhaled.
- H370: Causes damage to organs.
What is the melting point of Caffeine solution?