Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Loctite 586
- Product Code
- IDH234585
- Synonyms
- LOCTITE 586 250ML EPIG
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Threadlocker
Manufacturers & Suppliers
Henkel Singapore Pte Ltd
manufacturer
401 Commonwealth Drive, #03-01/02, Haw Par Technocentre, 149598 Singapore
+65 (6266) 0100
Emergency Contacts
Emergency Contact
+65 6424 7016
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If symptoms persist, seek medical advice.
Rinse with running water and soap. Obtain medical attention if irritation persists.
Rinse immediately with plenty of running water (for 10 minutes). Seek medical attention if necessary.
Rinse mouth, drink 1-2 glasses of water, do not induce vomiting, consult a doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide, foam, powder
High pressure waterjet
In case of fire, keep containers cool with water spray.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
For small spills wipe up with paper towel and place in container for disposal.
For large spills absorb onto inert absorbent material and place in sealed container for disposal.
Do not empty into drains / surface water / ground water.
For small spills wipe up with paper towel and place in container for disposal. For large spills absorb onto inert absorbent material and place in sealed container for disposal.
Materials: paper towel, inert absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only in well-ventilated areas. Prolonged or repeated skin contact should be avoided to minimise any risk of sensitisation. Avoid skin and eye contact. See advice in section 8
Store in original containers at 8-21°C (46.4-69.8°F) and do not return residual materials to containers as contamination may reduce the shelf life of the bulk product.
Prolonged or repeated skin contact should be avoided to minimise any risk of sensitisation. Avoid skin and eye contact.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide local and general exhaust ventilation to effectively remove and prevent buildup of any vapors or mists generated from the handling of this product.
Chemical-resistant protective gloves (EN 374). Suitable materials for short-term contact or splashes (recommended: at least protection index 2, corresponding to > 30 minutes permeation time as per EN 374): nitrile rubber (NBR; >= 0.4 mm thickness) Suitable materials for longer, direct contact (recommended: protection index 6, corresponding to > 480 minutes permeation time as per EN 374): nitrile rubber (NBR; >= 0.4 mm thickness) This information is based on literature references and on information provided by glove manufacturers, or is derived by analogy with similar substances. Please note that in practice the working life of chemical-resistant protective gloves may be considerably shorter than the permeation time determined in accordance with EN 374 as a result of the many influencing factors (e.g. temperature). If signs of wear and tear are noticed then the gloves should be replaced.
Wear protective glasses. Protective eye equipment should conform to EN166.
Ensure adequate ventilation. An approved mask or respirator fitted with an organic vapour cartridge should be worn if the product is used in a poorly ventilated area Filter type: A (EN 14387)
Wear suitable protective clothing. Protective clothing should conform to EN 14605 for liquid splashes or to EN 13982 for dusts.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Reacts with strong oxidants.
Stable
Reaction with strong acids.
Irritating organic vapours.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Bioaccumulative potential
Mobility in soil
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.1 Toxicity
Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
Persistence and degradability:
12.2 Persistence and degradability
The substance is not readily biodegradable.
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of in accordance with local and national regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Loctite 586 known by?
Loctite 586 is also known as: LOCTITE 586 250ML EPIG
What is the hazard signal word for Loctite 586?
The signal word is warning.
What is the physical form of Loctite 586?
Loctite 586 is a liquid appearing as red liquid with red color. It has characteristic odor.
What is the solubility of Loctite 586?
Not miscible
What is Loctite 586 used for?
Threadlocker
What are the hazard statements for Loctite 586?
This substance has 3 hazard statements:
- H319: Causes serious eye irritation.
- H335: May cause respiratory irritation.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of Loctite 586?
The melting point is Not applicable, Product is a liquid and the boiling point is > 150 °C (> 302 °F).