NextSDS Logo
Safety Data Sheet EN

pH 4.01 Buffer

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
pH 4.01 Buffer
Product Form
Mixture
Product Code
910104

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Use as laboratory reagent

Uses advised against

No Information available

Manufacturers & Suppliers

T

Thermo Fisher Scientific (Asheville) LLC

manufacturer

275 Aiken Road, Asheville, NC 28804

Emergency Contacts

CHEMTREC®

1-800-424-9300

CHEMTREC®

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Precautionary Statements

P404 Store in a closed container
P501 Dispose of contents in accordance with all local, regional, national and international guidelines.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Water 7732-18-5 90% No
Potassium Hydrogen Phthalate 877-24-7 0.1 - 1% No
Potassium Hydroxide 1310-58-3 0.1% No
Amaranth Red No. 27 915-67-3 0.1% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. Get medical attention immediately if symptoms occur.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes. Get medical attention immediately if symptoms occur.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

Clean mouth with water and drink afterwards plenty of water. Get medical attention if symptoms occur.

Immediate Medical Attention

Get medical attention immediately if symptoms occur.

Medical Treatment

Treat symptomatically

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

No information available

Specific hazards

No information available.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Should not be released into the environment.

Cleanup methods

Soak up with inert absorbent material. Pick up and transfer to properly labeled containers.

Materials: inert absorbent material

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wear personal protective equipment/face protection, Ensure adequate ventilation, Avoid contact with skin, eyes or clothing, Avoid ingestion and inhalation

Storage

Keep container tightly closed in a dry and well-ventilated place, Store at room temperature in the original container, Protect from direct sunlight

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Colorless
Colour
---
Colour Intensity
---
Form
---
Odor
Odorless
Odor Threshold
No information available
Ph
No information available
Melting Point
No information available
Boiling Point
No information available
Flash Point
330 °C
Freezing Point
---
Softening Point
No information available
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No information available
Vapor Pressure
No information available
Vapor Density
No information available
Relative Density
No information available
Bulk Density
No information available
Density
No Information available
Flammability
No information available
Upper Explosive Limit
No information available
Lower Explosive Limit
No information available
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
No information available
Solubility
---
Partition Coefficient
No information available
Solubility In Water
No information available
Solubility In Fat
---
Molecular Weight
No information available
Voc Content
No information available
Metal Corrosion
---
Dynamic Viscosity
No information available
Kinematic Viscosity
No information available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions

Reactivity

No Information available

Hazardous reactions

None under normal processing

Avoid

Extremes of temperature and direct sunlight.

Incompatible

No information available

Decomposition

Thermal decomposition can lead to release of irritating gases and vapors.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Ecotoxicity

0% of the mixture consists of components(s) of unknown hazards to the aquatic environment | Component | Freshwater Algae | Freshwater Fish | Water Flea | | --- | --- | --- | --- |

0% of the mixture consists of components of unknown hazards to the aquatic environment.

12.2 Persistence and degradability

No information provided

12.3 Bioaccumulative potential

No information provided

12.4 Mobility in soil

No information provided

12.5 Results of PBT and vPvB assessment

No information provided

12.6 Endocrine disrupting properties

No information provided

12.7 Other adverse effects

No information provided

12.1 Toxicity

LC50: = 80 mg/L, 96hr static (Gambusia affinis)

Persistence and Degradability

12.3 Bioaccumulative potential

Potassium Hydrogen Phthalate 877-24-7 | -3.9

12.1 Toxicity

12.2 Persistence and degradability

12.3 Bioaccumulative potential

Potassium Hydroxide 1310-58-3 | 0.83

12.4 Mobility in soil

12.5 Results of PBT and vPvB assessment

12.6 Endocrine disrupting properties

12.7 Other adverse effects

12.3 Bioaccumulative potential

| Amaranth Red No. 27 915-67-3 | -5.13 |

Other adverse effects

No information available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Disposal should be in accordance with applicable regional, national and local laws and regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for pH 4.01 Buffer?

The signal word is no signal word.

What is the physical form of pH 4.01 Buffer?

pH 4.01 Buffer is a liquid appearing as colorless . It has odorless odor.

What is pH 4.01 Buffer used for?

Use as laboratory reagent

What is the melting point of pH 4.01 Buffer?

The melting point is No information available and the boiling point is No information available.