NextSDS Logo
Safety Data Sheet EN

Powergas

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Powergas
Product Code
220383, 220483

Regulatory Identifiers

CAS Number
N/A
UFI Code
XUAP-5MJG-600P-UQQA

Identified Uses

Propellants

Manufacturers & Suppliers

S

Sievert AB

manufacturer

Box 1366, 17126 SOLNA, Sweden

+46 (0)8-629 22 00

Emergency Contacts

Emergency Contact

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Gas Cat. 1A H220
Press. Gas (Liq.) H280

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H220 Extremely flammable gas
H280 Contains gas under pressure; may explode if heated

Precautionary Statements

P102 Keep out of reach of children
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking
P377 Leaking gas fire: Do not extinguish, unless leak can be stopped safely
P381 In case of leakage, eliminate all ignition sources
P410 + P403 Protect from sunlight. Store in a well-ventilated place

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
BUTANE EC: 203-448-7 106-97-8 60% Yes
PROPANE EC: 200-827-9 74-98-6 40% Yes

Explanations to the classification and labelling of the ingredients are given in Section 16e. Official abbreviations are printed in normal font. Text in italics are specifications and/or complements used in the calculation of the classification of this mixture, see Section 16b.

Notes

Note that the table shows known hazards of the ingredients in pure form. These hazards are reduced or eliminated when mixed or diluted, see Section 16d.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Bring the injured person out into fresh air. Give artificial respiration if breathing has stopped. If breathing is difficult let trained personnel administer oxygen. Let the injured person rest in a warm place with fresh air and seek medical advice immediately.

Symptoms: High concentrations can displace the normal air and cause suffocation from lack of oxygen.

Skin contact

Remove contaminated clothes. Heat the exposed body part in lukewarm water if cold injury occurs. Do NOT use warm water. Frostbite should be treated by a doctor.

Symptoms: Contact with rapidly expanding gas may cause frostbite.

Eye contact

Remove contact lenses immediately if possible. Rinse the eye for several minutes with lukewarm water. If irritation persists call a doctor/ophthalmologist.

Symptoms: Frostbites.

Ingestion

If symptoms persist contact a doctor.

Symptoms: Frostbites.

Immediate Medical Attention

Transport the injured person to fresh air and administer oxygen immediately, and transport them to a hospital immediately. Let the injured person rest in a warm place with fresh air and seek medical advice immediately.

Medical Treatment

Symptomatic treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

powder, carbon dioxide or foam

Unsuitable media

water dispersed under high pressure

Specific hazards

Gases detrimental to health (carbon monoxide and carbon dioxide) can be spread in case of fire. In case of fire, high pressure may build up causing the packaging to explode. The gas forms an explosive mixture with air. Flammable gas.

Instructions

Containers in the proximity of fire should be moved and cooled down with water. If the gas cylinder cannot be removed, cool it with water as long as the fire persists and then at least 10 minutes. Protective measures should be taken regarding other material at the site of the fire.

Firefighter Protection

In case of fire use proper breathing apparatus. Wear full protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use recommended safety equipment, see section 8. Do not inhale the gas. Area should be evacuated and gases removed with ventilation. Note, risk of ignition and explosion. Switch off equipment which has an exposed flame, glows, or has a heat source of some other kind. Note, risk for formation of sparks due to static electricity. Do not remove clothing in a room where spillage has occurred.

Environmental

Notify rescue services for larger spillage. Prevent from entering sewers, basements and pits, or any place where gas accumulation could be dangerous.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid spillage, inhalation and contact with eyes and skin. Only experienced and properly instructed persons must handle compressed gas. Use only correctly specified equipment suitable for this substance, its pressure and temperature. Please contact your gas supplier in case of doubt. Take precautionary measures against static discharge. Pressurized container: Do not pierce or burn, even after use. Protect from sunlight. Do no expose to temperatures exceeding 50 °C.

Storage

Protect from sunlight. Do no expose to temperatures exceeding 50 °C.

Hygiene

Do not eat, drink or smoke in premises where this product is handled.

Fire prevention

Open fires, hot objects, spark formation, or other sources of ignition, are not allowed in the premises where this product is handled. Prevent build up of static electricity by utilising a semi-conducting floor and shoe soles and keep humidity above 50%.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

The ventilation in the workplace must ensure an air quality that meets the requirements of the current working environment legislation. Local exhaust ventilation should be used to remove airborne contaminants at the source. Oxygen monitors should be used since suffocating gases may be released.

Hands

Gloves protecting against cold, labelled with the "cold hazard" pictogram, is recommended.

Eyes

Eye protection should be worn if there is any danger of direct exposure or splashing.

Respiratory

Use appropriate respiratory protective equipment in case of insufficient ventilation. Breathing apparatus may be required.

Environmental

Work with the product should take place in such a way that the product does not get into drains, waterways, soil and air.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Gas
Physical State Data
gas
State Under Standard Conditions
---
Appearance
---
Colour
colourless
Colour Intensity
---
Form
Liquefied gas mixture
Odor
Distinctive and unpleasant if odorized, otherwise odorless
Odor Threshold
---
Ph
---
Melting Point
-188 °C
Boiling Point
-42 °C
Flash Point
-40 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
430 kPa (15°C)
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0.5 kg/L
Flammability
---
Upper Explosive Limit
11 %
Lower Explosive Limit
2 %
Explosive Limits
---
Auto Ignition Temperature
450 °C
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable at normal storage and handling conditions.

Reactivity

The product contains no substances which can lead to hazardous reactions at normal use.

Hazardous reactions

Reacts strongly or explosively with certain oxidising agents.

Avoid

Avoid heat, sparks and open flames. Protect from direct sunlight.

Incompatible

Avoid contact with oxidizers. Avoid contact with halogens.

Decomposition

None under normal conditions.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

In the quantities with which this product is used, effects on the environment are negligible. Note however, that the local environment may be affected, and all discharge to the natural environment may impact ecosystems. PROPANE LC50 Freshwater water flea (Daphnia magna) 48h: 16.3 mg/L LC50 Fish 96h: 16.1 mg/L IC50 Algae 72h: 11.3 mg/L

12.2. Persistence and degradability

12.2. Persistence and degradability

12.2. Persistence and degradability

The product degrades easily in the natural environment.

The product degrades easily in the natural environment.

12.3. Bioaccumulative potential

12.3. Bioaccumulative potential

12.3. Bioaccumulative potential

Neither this product, nor its contents, accumulates in nature.

The product and its contents do not accumulate in nature.

12.4. Mobility in soil

No information about mobility in the nature exists but there is no reason to suppose the product to be ecologically harmful because of this. Evaporates quickly in air.

No information about mobility in the nature exists but there is no reason to suppose the product to be ecologically harmful because of this. Evaporates quickly in air.

12.5. Results of PBT and vPvB assessment

This product does not contain any substances that are assessed to be a PBT or a vPvB.

The product does not contain any substances that are assessed to be a PBT or a vPvB.

12.6. Endocrine disrupting properties

Not indicated.

Not indicated.

12.7. Other adverse effects

Large emissions into the air, in combination with sunlight, can create ground-level ozone and may result in damage to vegetation, as well as respiratory difficulties for humans and animals.

Large emissions into the air can contribute to ground-level ozone formation, potentially damaging vegetation and causing respiratory issues.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Product as well as packaging must be disposed of as hazardous waste.

Disposal

Product as well as packaging must be disposed of as hazardous waste.

Waste Codes

16 05 04 Gases in pressure containers (including halons) containing dangerous substances EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
2037
Shipping Name
RECEPTACLES, SMALL, CONTAINING GAS (GAS CARTRIDGES)
Transport Class
2
ADR

Tunnel category: D

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Not indicated.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Powergas?

The signal word is danger.

What is the physical form of Powergas?

Powergas is a gas with colourless color. It has distinctive and unpleasant if odorized, otherwise odorless odor.

What is Powergas used for?

Propellants

What are the hazard statements for Powergas?

This substance has 2 hazard statements:

  • H220: Extremely flammable gas
  • H280: Contains gas under pressure; may explode if heated

What is the melting point of Powergas?

The melting point is -188 °C and the boiling point is -42 °C.