01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
NYNAS® T 3
Product Form
Liquid.
Chemical Name
Base oil

Regulatory Identifiers

CAS Number
64742-53-6 Check regulations →
EC Number
265-156-6 Check regulations →
REACH No.
01-2119480375-34-0000

Identified Uses

Formulation and (re)packing of substances and mixtures - Industrial Use in coatings - Industrial Use in coatings - Professional Lubricants - Industrial Lubricants Low release - Professional Use in metal working fluids/rolling oils - Industrial Use in metal working fluids/rolling oils - Professional Use in rubber production and processing - Industrial Functional Fluids - Industrial Functional Fluids - Professional

Uses advised against

This product must not be used in applications other than those recommended in Section 1, without first seeking the advice of the supplier.

Manufacturers & Suppliers

Nynas AB (publ) logo

Nynas AB (publ)

manufacturer

Kabyssgatan 4D, 120 30 Stockholm, SWEDEN

+46 8 602 12 00

http://www.nynas.com

Emergency Contacts

Kemiakuten

020 - 99 60 00

24h service

Emergency Contact

+44 (0) 1235 239 670

24 hour service

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Asp. Tox. Cat. 1 H304

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H304 May be fatal if swallowed and enters airways.

Precautionary Statements

P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER or doctor.
P331 Do NOT induce vomiting.
P501 Dispose of contents/container through authorized contractor or collector.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type uvcb
Chemical Name CAS Number Concentration Hazardous
Distillate (petroleum), hydrotreated light naphthenic EC: 265-156-6 64742-53-6 100% Yes

There are no additional ingredients present which, within the current knowledge of the supplier, are classified and contribute to the classification of the substance and hence require reporting in this section.

Notes

Regulation (EC) No. 1272/2008 [CLP] Annex VI Nota L applies to the base oil(s) in this product. Nota L - The classification as a carcinogen need not apply if it can be shown that the substance contains less than 3 % DMSO extract as measured by IP 346.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. If casualty is unconscious and: If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. Get medical attention if adverse health effects persist or are severe. Maintain an open airway.

Symptoms: Inhalation of oil mist or vapours at elevated temperatures may cause respiratory irritation.

Skin contact

Wash skin thoroughly with soap and water or use recognised skin cleanser. Remove contaminated clothing and shoes. Handle with care and dispose of in a safe manner. Seek medical attention if skin irritation, swelling or redness develops and persists.

Symptoms: Adverse symptoms may include the following: irritation, dryness, cracking

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Continue to rinse for at least 10 minutes. Check for and remove any contact lenses. Get medical attention if irritation occurs. Get medical attention.

Ingestion

Accidental high pressure injection through the skin requires immediate medical attention. Do not wait for symptoms to develop. Always assume that aspiration has occurred. Do not induce vomiting. Can enter lungs and cause damage. Seek professional medical attention or send the casualty to a hospital. Do not wait for symptoms to develop. Never give anything by mouth to an unconscious person. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: Can enter lungs and cause damage.

Immediate Medical Attention

Accidental high pressure injection through the skin requires immediate medical attention. If unconscious, place in recovery position and get medical attention immediately.

Medical Treatment

Due to low viscosity there is a risk of aspiration if the product enters the lungs. Treat symptomatically. No specific treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, water spray (fog) or foam.

Unsuitable media

Do not use direct water jets on the burning product; they could cause splattering and spread the fire. Simultaneous use of foam and water on the same surface is to be avoided as water destroys the foam.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst. This substance will float and can be reignited on surface water. Incomplete combustion is likely to give rise to a complex mixture of airborne solid and liquid particulates, gases, including carbon monoxide, H2S, SOx (sulfur oxides) or sulfuric acid and unidentified organic and inorganic compounds.

Instructions

No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Stop leak if safe to do so. Avoid direct contact with the product. Stay upwind/keep distance from source. In case of large spillages, alert occupants in downwind areas.

Small spill

In case of small spillages in closed waters (i.e. ports), contain product with floating barriers or other equipment. Collect spilled product by absorbing with specific floating absorbents.

Large spill

In case of large spillages, alert occupants in downwind areas.

Environmental

Prevent product from entering sewers, rivers or other bodies of water.

Cleanup methods

Absorb spilled product. Transfer collected product and other contaminated materials to suitable containers for recovery or safe disposal.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not ingest. Do not breathe dust/fume/gas/mist/vapours/spray. Avoid contact with eyes, skin and clothing. Prevent the risk of slipping. Take precautionary measures against static discharge. Avoid splash filling of bulk volumes when handling hot liquid product. Empty containers retain product residue and can be hazardous. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Do not reuse container. Do not swallow.

Storage

Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use.

Hygiene

Ensure that proper housekeeping measures are in place. Contaminated materials should not be allowed to accumulate in the workplaces and should never be kept inside the pockets. Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Wash hands thoroughly after handling. Change contaminated clothes at the end of working shift.

Fire prevention

Take precautionary measures against static discharge.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Wear suitable gloves tested to EN374. 4 - 8 hours (breakthrough time): nitrile rubber thickness >0,35 mm Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. Use eye protection according to EN 166. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. Use a properly fitted, particulate filter respirator complying with an approved standard if a risk assessment indicates this is necessary. organic vapour (Type A) and particulate filter (EN 140, EN 143, EN 14387)

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Wear protective clothing if there is a risk of skin contact. (EN 943) Change contaminated clothes at the end of working shift.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Light yellow
Colour Intensity
---
Form
---
Odor
Light petroleum.
Odor Threshold
---
Ph
Not applicable.
Melting Point
<-60°C [ASTM D 5950 ASTM D 97]
Boiling Point
>200°C (>392°F) [ASTM D 2887]
Flash Point
Closed cup: >101°C (>213,8°F) [ASTM D 93]
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
>0,01 kPa (>0,075006 mm Hg)
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0,87 g/cm³ [15°C (59°F)] [ASTM D 4052]
Flammability
Not available.
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
>200°C (>392°F)
Decomposition Temperature
>280°C
Solubility
---
Partition Coefficient
2 to 6
Solubility In Water
Insoluble in water.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not available.
Kinematic Viscosity
3,8 mm2/s (3,8 cSt) [ASTM D 445]
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Keep away from extreme heat and oxidizing agents. Take precautionary measures against static discharge.

Incompatible

oxidizing agents

Decomposition

Incomplete combustion is likely to give rise to a complex mixture of airborne solid and liquid particulates, gases, including carbon monoxide, H2S, SOx (sulfur oxides) or sulfuric acid and unidentified organic and inorganic compounds.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

12.1 Toxicity

12.1 Toxicity

Product/ingredient name | Method | Type | Result | References Distillate (petroleum), | OECD 203 [Fish, Acute | Acute - LL50 | >100 mg/l [96 | Exxon 1995 hydrotreated light naphthenic | Toxicity Test] | hours] - | OECD 202 [Daphnia sp. | Acute - EL50 | >10000 mg/l [48 | Shell 1988 Acute Immobilization Test | hours] and Reproduction Test] - | OECD 201 [Alga, Growth | Acute - NOEL | >100 mg/l [72 | Petro-Canada Inhibition Test] | hours] | 2008 - | OECD 211 [Daphnia Magna | Chronic - NOEL - | 10 mg/l [21 days] Shell 1995 Reproduction Test] | Fresh water Conclusion/Summary | Based on available data, the classification criteria are not met.

Based on available data, the classification criteria are not met.

12.2 Persistence and degradability

Product/ingredient name | Biodegradability Distillate (petroleum), hydrotreated light naphthenic | Not readily Conclusion/Summary | Not readily biodegradable. This product is inherently biodegradable.

Not readily biodegradable. This product is inherently biodegradable.

12.3 Bioaccumulative potential

12.3 Bioaccumulative potential

12.3 Bioaccumulative potential

Product/ingredient name | LogPow | BCF | Potential Distillate (petroleum), | 2 to 6 | <500 | Low hydrotreated light naphthenic Conclusion/Summary | The product has a potential to bioaccumulate.

The product has a potential to bioaccumulate.

12.4 Mobility in soil

Soil/water partition coefficient Not available. Mobility | High mobility in soil predicted, based on log Kow > 3.0.

Results of PMT and vPvM assessment

Conclusion/Summary | The product does not meet the criteria to be considered as a PMT or vPvM.

12.5 Results of PBT and vPvB assessment

Conclusion/Summary Regulation | The product does not meet the criteria to be considered as a PBT or vPvB. (EC) No. 1272/2008 [CLP]

The product does not meet the criteria to be considered as a PBT or vPvB.

12.6 Endocrine disrupting properties

Based on available data, the classification criteria are not met.

12.7 Other adverse effects

Insoluble in water. Spills may form a film on water surfaces causing physical damage to organisms. Oxygen transfer could also be impaired.

The substance is insoluble in water; spills may form a film on water surfaces, potentially causing physical damage to organisms and impairing oxygen transfer.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Disposal can be carried out directly, or by delivery to qualified waste handlers. Where possible (e.g. in the absence of relevant contamination), recycling of used substance is feasible and recommended.

Disposal

In the absence of relevant alterations to the material or presence of contaminants, disposal of this substance as surplus (unused) or off-spec material, or waste resulting from the foreseeable use(s), does not present a specific hazard, or require special handling measures other than those indicated in Sect. 7. This substance can be burned or incinerated, subject to national/local authorizations, relevant contamination limits, safety regulations and air quality legislation.

Waste Codes

13 08 99* wastes not otherwise specified EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

None of the components are listed for REACH Annex XIV or SVHC. Not controlled under Seveso Directive. All components listed or exempted in major international inventories.

Chemical Safety Assessment Performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for NYNAS® T 3?

The signal word is danger.

What is the physical form of NYNAS® T 3?

NYNAS® T 3 is a liquid. with light yellow color. It has light petroleum. odor.

What is NYNAS® T 3 used for?

Formulation and (re)packing of substances and mixtures - Industrial Use in coatings - Industrial Use in coatings - Professional Lubricants - Industrial Lubricants Low release - Professional Use in metal working fluids/rolling oils - Industrial Use in metal working fluids/rolling oils - Professional Use in rubber production and processing - Industrial Functional Fluids - Industrial Functional Fluids - Professional

What are the hazard statements for NYNAS® T 3?

This substance has 1 hazard statement:

  • H304: May be fatal if swallowed and enters airways.

What is the melting point of NYNAS® T 3?

The melting point is <-60°C [ASTM D 5950 ASTM D 97] and the boiling point is >200°C (>392°F) [ASTM D 2887].