Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Triton™ X-100
- Product Code
- X100
Regulatory Identifiers
- CAS Number
- 9036-19-5 Check regulations →
Identified Uses
Laboratory chemicals, Synthesis of substances
Uses advised against
The product is being supplied under the TSCA R&D Exemption (40 CFR Section 720.36). It is the recipient's responsibility to comply with the requirements of the R&D exemption. The product may not be used for a non-exempt commercial purpose under TSCA unless appropriate consent is granted in writing by MilliporeSigma.
Manufacturers & Suppliers
Sigma-Aldrich Inc.
manufacturer
SPRUCE ST 3050 St. Louis 63103 United States
(314) 771-5765
Emergency Contacts
CHEMTREC
+1 703 527 3887
24/7
CHEMTREC
1 800 424 9300
24/7
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Octylphenol polyethoxyethanol | 9036-19-5 | 80 - 100% | No |
| Polyethylene glycol, average MW 8,000 | 25322-68-3 | 1 - 5% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air.
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.
After eye contact: rinse out with plenty of water. Immediately call in ophthalmologist. Remove contact lenses.
After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.
Immediate Medical Attention
Immediately call in ophthalmologist.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water, Foam, Carbon dioxide (CO2), Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Combustible. Vapours are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating. Development of hazardous combustion gases or vapours possible in the event of fire.
Firefighter Protection
Prevent fire extinguishing water from contaminating surface water or the ground water system. Prevent skin contact by keeping a safe distance.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe vapours, aerosols. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up with liquid-absorbent material (e.g. Chemizorb® ). Dispose of properly. Clean up affected area.
Materials: liquid-absorbent material (e.g. Chemizorb® )
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For precautions see section 2 GHS label elements
Tightly closed. Keep locked up or in an area accessible only to qualified or authorised persons.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No data available
Material: butyl-rubber, Break through time: 480 min, Glove thickness: 0.7 mm, Protective index: Full contact, Manufacturer: Butoject® (KCL 898); Material: butyl-rubber, Break through time: 480 min, Glove thickness: 0.7 mm, Protective index: Splash contact, Manufacturer: Butoject® (KCL 898); Remarks: This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D- 36124 Eichenzell, Internet: www.kcl.de).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Tightly fitting safety goggles
required when vapours/aerosols are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter A-(P2). The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
protective clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature) .
Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical.
Violent reactions possible with: Strong oxidizing agents, Strong acids
Strong heating.
No data available
No data available. For Hazardous combustion products in the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Ecotoxicity
12.1 Toxicity
Toxicity
Persistence and degradability
12.2 Persistence and degradability
Persistence and degradability
Bioaccumulative potential
Mobility in soil
Other adverse effects
The product does not contain or was not manufactured with Class I or Class II ozone-depleting substances as defined by the U.S. Clean Air Act.
Endocrine disrupting properties
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Waste material must be disposed of in accordance with the national and local regulations.
Leave chemicals in original containers. No mixing with other waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3082
- Shipping Name
- Environmentally hazardous substance, liquid, n.o.s. (p-tertiary-Octylphenoxy polyethyl alcohol)
- Transport Class
- 9
- Packing Group
- III
EHS-Mark required (ADR 2.2.9.1.10, IMDG code 2.10.3) for single packagings and combination packagings containing inner packagings with Dangerous Goods > 5L for liquids or > 5kg for solids. Packages smaller than or equal to 5 kg / L , not dangerous goods of Class 9
EHS-Mark required (ADR 2.2.9.1.10, IMDG code 2.10.3) for single packagings and combination packagings containing inner packagings with Dangerous Goods > 5L for liquids or > 5kg for solids. Packages smaller than or equal to 5 kg / L , not dangerous goods of Class 9
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Triton™ X-100?
The signal word is danger.
What is the physical form of Triton™ X-100?
Triton™ X-100 is a liquid appearing as viscous liquid with colourless color. It has weak odor.
What is Triton™ X-100 used for?
Laboratory chemicals, Synthesis of substances
What are the hazard statements for Triton™ X-100?
This substance has 4 hazard statements:
- H302: Harmful if swallowed.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of Triton™ X-100?
The melting point is 43 °F / 6 °C and the boiling point is > 392 °F / > 200 °C (1,013 hPa).