NextSDS Logo
PL

PLAFOND EXTRA MAT / PLAFOND EXTRA MAT

NO SIGNAL WORD Liquide. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
PLAFOND EXTRA MAT / PLAFOND EXTRA MAT

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Peinture en phase aqueuse pour intérieur.

Overview

PLAFOND EXTRA MAT / PLAFOND EXTRA MAT commonly used peinture en phase aqueuse pour intérieur..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • P101: En cas de consultation d'un médecin, garder à disposition le récipient ou l'étiquette.
  • P102: Tenir hors de portée des enfants.
  • P262: Éviter tout contact avec les yeux, la peau ou les vêtements.
  • P312: Appeler un CENTRE ANTIPOISON ou un médecin en cas de malaise.
  • P501: Eliminer le contenu et le récipient conformément aux réglementations locales, régionales, nationales ou internationales.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Akzo Nobel Paints Belgium N.V.

manufacturer

📍

G. Levisstraat 2, B 1800 Vilvoorde - Belgium

🌍

BE

📞

+32 (0) 2 254 2211

📠

+32 (0) 2 254 2335

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Antipoisoncenter / Antigifcentrum/Centre Antipoisons/ Antigiftzentrum

📞

+32 2 254 22 11

🌍

BE

🕒

24 Hours/day, every day

Antipoisoncenter / Antigifcentrum/Centre Antipoisons/ Antigiftzentrum

📞

+32 (0) 70/245 245

🌍

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C9-C11, n- alkanes, isoalkanes, cyclics, < 2% aromatics
EC: 265-150-3
64742-48-9 1-3% ⚠️ Hazardous
Distillates (petroleum); hydrotreated light
EC: 265-149-8
64742-47-8 1-3% ⚠️ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Emmener à l'air frais. Garder la personne au chaud et au repos. Si elle ne respire pas, en cas de respiration irrégulière ou d'arrêt respiratoire, que le personnel qualifié pratique la respiration artificielle ou administre de l'oxygène.

Symptoms:

Maux de tête, vertiges, fatigue, faiblesse musculaire, somnolence et, dans les cas extrêmes, évanouissement.

🖐️ Skin Contact

Retirer les vêtements et les chaussures contaminés. Laver soigneusement la peau au savon et à l'eau ou utiliser un nettoyant cutané reconnu. NE PAS UTILISER de solvants ni de diluants.

Symptoms:

Déshydratation de la peau, provoquant une dermatite de contact non allergique.

👁️ Eye Contact

Enlever les lentilles de contact. Laver abondamment avec de l'eau douce et propre en maintenant les paupières écartées pendant au moins 10 minutes et faire appel immédiatement à un médecin.

Symptoms:

Irritation et atteintes réversibles.

🍽️ Ingestion/Swallowing

En cas d'ingestion, consulter immédiatement un médecin et lui montrer l'emballage ou l'étiquette. Garder la personne au chaud et au repos. NE PAS faire vomir.

Symptoms:

Nausées, diarrhées et vomissements.

🚨 Immediate Medical Attention Required

Contacter immédiatement un spécialiste pour le traitement des intoxications, si de grandes quantités ont été ingérées ou inhalées.

Medical Treatment

Traitement symptomatique requis.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Liquide.
Critical Property
📊 Physical State Data
liquid
📊 State Under Standard Conditions
Not available
👁️ Appearance
Not available
🎨 Colour
Non disponible.
📊 Colour Intensity
Not available
📊 Form
Not available
👃 Odor
Non disponible.
📊 Odor Threshold
Non disponible.
🧪 Ph
Non disponible.
🧊 Melting Point
Non disponible.
Critical Property
💨 Boiling Point
100℃
Critical Property
🔥 Flash Point
Non applicable.
Critical Property
📊 Freezing Point
Non disponible.
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Non disponible.
💨 Vapor Pressure
Non disponible.
📊 Vapor Density
Non disponible.
📊 Relative Density
1.569
📊 Bulk Density
Not available
⚖️ Density
Not available
🔥 Flammability
Non disponible.
📊 Upper Explosive Limit
Non disponible.
📊 Lower Explosive Limit
Non disponible.
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
Non disponible.
📊 Decomposition Temperature
Non disponible.
💧 Solubility
Facilement soluble dans les substances suivantes: l'eau froide.
📊 Partition Coefficient
Non disponible.
📊 Solubility In Water
Non disponible.
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
Not available
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
Not available
📊 Kinematic Viscosity
10.2 cm2/s
📊 Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Assurer une ventilation adéquate. Lorsque c'est raisonnablement possible, il est recommandé d'utiliser une ventilation par aspiration localisée et une extraction générale efficace. Si ceci ne suffit pas à maintenir des concentrations de particules et de vapeurs de solvants inférieures à la VLEP, une protection respiratoire appropriée doit être utilisée.

🧤 Hand Protection

En cas de contact prolongé ou répété, utiliser des gants. Des crèmes protectrices peuvent aider à protéger les zones exposées de la peau, mais elles ne doivent pas être appliquées après l'exposition. Nettoyer soigneusement la peau après tout contact avec le produit. Utiliser des gants homologués EN 374 résistants aux produits chimiques : gants de protection contre les produits chimiques et les micro-organismes. Gants recommandés : Viton ® or Nitrile. Temps de rupture minimum : 480 mn. Pour un contact prolongé ou fréquement répété, des gants de classe de protection 6 (temps de rupture supérieur à 480 minutes selon la norme EM 374) sont recommandés. Pour un contact bref, des gants de classe de protection 2 ou classe supérieure (temps de rupture supérieur à 30 minutes selon la norme EN 374) sont recommandés. Le choix du type de gants pour l'application donnée et pour la durée d'utilisation en milieu de travail doit aussi tenir compte de tous les facteurs pertinents suivants, sans en exclure d'autres : autres produits chimiques utilisés, exigences physiques (protection contre lês coupures/perforations, dextérité, protection thermique), réactions corporelles potentielles aux materiaux des gants, ainsi que toutes les directives et spécifications fournies par le fournisseur de gants. L'utilisateur doit vérifier que les types de gants qu'il choisit de porter pour la manipulation de ce produit est le plus approprié et prend en compte les conditions d'utilisation particulières, conformément aux indications stipulées dans l'évaluation des risques de l'utilisateur.

👁️ Eye Protection

Utiliser une protection oculaire de sécurité assurant une protection contre les éclaboussures de liquides.

😷 Respiratory Protection

Les ouvriers exposés à des concentrations supérieures à la limite d'exposition doivent porter des appareils de protection respiratoire appropriés et homologués. Protection respiratoire en cas de formation de poussières : Filtre à particule type P2 (EN 143). Protection respiratoire en cas de formation de vapeurs : Demi-masque respiratoire avec filtres combinés A2-P2 (jusqu'à une concentration de 0,5% en volume).

🦺 Skin/Body Protection

Le personnel doit porter des vêtements antistatiques en fibres naturelles ou en fibres synthétiques résistant aux températures élevées. Des chaussures adéquates et toutes mesures de protection corporelle devraient être déterminées en fonction de l'opération effectuée et des risques impliqués, et devraient être approuvées par un spécialiste avant toute manipulation de ce produit.

🌍 Environmental Exposure Controls

Ne pas laisser pénétrer dans les égouts ni les cours d'eau.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

📦 Proper Shipping Name

Non applicable.

⚠️ Transport Hazard Class

Non applicable.

📋 Packing Group

Non applicable.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for PLAFOND EXTRA MAT / PLAFOND EXTRA MAT?

The signal word for this substance is "no signal word".

What is the physical form of PLAFOND EXTRA MAT / PLAFOND EXTRA MAT?

PLAFOND EXTRA MAT / PLAFOND EXTRA MAT is a liquide. with non disponible. color. It has non disponible. odor.

What is the solubility of PLAFOND EXTRA MAT / PLAFOND EXTRA MAT?

Facilement soluble dans les substances suivantes: l'eau froide.

What is PLAFOND EXTRA MAT / PLAFOND EXTRA MAT used for?

Peinture en phase aqueuse pour intérieur.

What is the melting point of PLAFOND EXTRA MAT / PLAFOND EXTRA MAT?

The melting point is Non disponible. and the boiling point is 100℃.