NextSDS Logo
Ru

Rubson Peinture Anti Humidité

NO SIGNAL WORD SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Rubson Peinture Anti Humidité

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Revêtements

Overview

Rubson Peinture Anti Humidité is a liquide substance commonly used revêtements.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • P102: Tenir hors de portée des enfants.
  • P262: Éviter tout contact avec les yeux, la peau ou les vêtements.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Henkel Technologies France S.A.S

manufacturer

📍

Rue de Silly 161, 92642 Boulogne-Billancourt cedex, France

🌍

FR

📞

+33 (1) 46 84 90 00

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Centre Anti-Poisons de Paris, France

📞

+33.1.40.05.48.48

🌍

FR

🕒

24h

I.N.R.S.

📞

01 45 42 59 59

🌍

FR

🕒

24h

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Revêtement de protection, Copolymère d'acrylate, Matières de charge inorganiques

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Diisobutyrate de 1-isopropyl-2,2- dimethyltrimethylene
EC: 229-934-9
6846-50-0 1-2.5% ⚠️ Hazardous
triethoxy(2,4,4-triméthylpentyl)silane
EC: 252-558-1
35435-21-3 1-3% ⚠️ Hazardous
2-octyl-2H-isothiazole-3-one
EC: 247-761-7
26530-20-1 50-500% ⚠️ Hazardous
5-Chloro-2-methyl-2H-isothiazol-3-one and 2-methyl-2H-isothiazol-3-one (3:1) 55965-84-9 1.5-15% ⚠️ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Air frais; en cas de persistance des maux, consulter un médecin.

🖐️ Skin Contact

Laver à l'eau courante et au savon. Soin de la peau. Enlever les vêtements souillés, imbibés.

👁️ Eye Contact

Rincer à l'eau courante, si nécessaire consulter un médecin.

🍽️ Ingestion/Swallowing

Rincer l'intérieur de la bouche, boire 1 à 2 verres d'eau, consulter un médecin.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Not available
📊 Physical State Data
Not available
📊 State Under Standard Conditions
Not available
👁️ Appearance
liquide
🎨 Colour
blanc
📊 Colour Intensity
Not available
📊 Form
Not available
👃 Odor
inodore
📊 Odor Threshold
Il n'y a pas de données / Non applicable
🧪 Ph
8,5 - 10,5
🧊 Melting Point
Il n'y a pas de données / Non applicable
Critical Property
💨 Boiling Point
Il n'y a pas de données / Non applicable
Critical Property
🔥 Flash Point
Préparation aqueuse
Critical Property
📊 Freezing Point
Not available
📊 Softening Point
Not available
📊 Solidification Point
Il n'y a pas de données / Non applicable
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Il n'y a pas de données / Non applicable
💨 Vapor Pressure
Il n'y a pas de données / Non applicable
📊 Vapor Density
Il n'y a pas de données / Non applicable
📊 Relative Density
Not available
📊 Bulk Density
Il n'y a pas de données / Non applicable
⚖️ Density
1,40 - 1,6 g/cm3
Critical Property
🔥 Flammability
Il n'y a pas de données / Non applicable
📊 Upper Explosive Limit
Not available
📊 Lower Explosive Limit
Not available
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
Il n'y a pas de données / Non applicable
📊 Decomposition Temperature
Il n'y a pas de données / Non applicable
💧 Solubility
Miscible
📊 Partition Coefficient
Il n'y a pas de données / Non applicable
📊 Solubility In Water
Not available
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
Not available
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
18.000 - 35.000 mpa.s
📊 Kinematic Viscosity
Il n'y a pas de données / Non applicable
📊 Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Utiliser seulement dans des zones bien ventilées.

🧤 Hand Protection

Les gants recommandés sont des gants en caoutchouc nitrile (épaisseur >0.1mm, temps de pénétration < 30s). Les gants devront être changé après chaque contact même court ou contamination. Gants disponibles en magasins spécialisés: laboratoires, parmacies ...

👁️ Eye Protection

Lunettes de protection

😷 Respiratory Protection

Utiliser seulement dans des zones bien ventilées.

🦺 Skin/Body Protection

vêtement de protection approprié

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Rubson Peinture Anti Humidité?

The signal word for this substance is "no signal word".

What is the solubility of Rubson Peinture Anti Humidité?

Miscible

What is Rubson Peinture Anti Humidité used for?

Revêtements

What is the melting point of Rubson Peinture Anti Humidité?

The melting point is Il n'y a pas de données / Non applicable and the boiling point is Il n'y a pas de données / Non applicable.