Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Weber Égalisation commonly used chimie de la construction.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS05
GHS07
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H315: Provoque une irritation cutanée.
- H318: Provoque de graves lésions des yeux.
- H317: Peut provoquer une allergie cutanée.
Precautionary Statements
- P101: En cas de consultation d'un médecin, garder à disposition le récipient ou l'étiquette.
- P102: Tenir hors de portée des enfants.
- P103: Lire l'étiquette avant utilisation.
- P280: Porter des gants de protection/des vêtements de protection/un équipement de protection des yeux/du visage.
- P302+P352: EN CAS DE CONTACT AVEC LA PEAU: Laver abondamment à l'eau.
- P305+P351+P338: EN CAS DE CONTACT AVEC LES YEUX: Rincer avec précaution à l'eau pendant plusieurs minutes. Enlever les lentilles de contact si la victime en porte et si elles peuvent être facilement enlevées. Continuer à rincer.
- P310: Appeler immédiatement un CENTRE ANTIPOISON/un médecin.
- P362: Enlever les vêtements contaminés.
- P501: Éliminer le contenu/récipient conformément à la réglementation locale/régionale/ nationale/internationale.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Saint-Gobain Weber Beamix B.V.
manufacturer
Postbus 7932, 5606 SH Eindhoven
NL
+31 (0)40 259 79 11
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Centre anti-poison
+32 (0)70 245 245
BE
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
Mélange des substances mentionnées à la suite avec des additifs non dangereux.
Chemical Components & Hazardous Substances
Chemical Name | CAS Number | Concentration | Hazardous |
---|---|---|---|
filler calcaire EC: 207-439-9 | 471-34-1 | 25-50% | ⚠️ Hazardous |
ciment Portland, gris EC: 266-043-4 | 65997-15-1 | 2-5% | ⚠️ Hazardous |
sulfate de calcium, naturel EC: 231-900-3 | 7778-18-9 | 1-2% | ⚠️ Hazardous |
distillats paraffiniques lourds (pétrole), déparaffinés au solvant EC: 265-169-7 | 64742-65-0 | 0.1-1% | ⚠️ Hazardous |
Additional Information
Pour le libellé des phrases de risque citées, se référer au chapitre 16.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
🫁 Inhalation Exposure
Donner de l'air frais, consulter un médecin en cas de troubles.
🖐️ Skin Contact
Laver immédiatement à l'eau.
👁️ Eye Contact
Rincer les yeux, pendant plusieurs minutes, sous l'eau courante en écartant bien les paupières. Si les troubles persistent, consulter un médecin.
🍽️ Ingestion/Swallowing
Rincer la bouche avec de l'eau. Ne pas provoquer de vomissement. Aller chercher un médecin et lui présenter cette fiche de données.
Fire Fighting Measures & Emergency Response
Fire suppression methods, extinguishing media, and firefighting safety procedures
⚠️ Specific Fire Hazards
Pas d'autres informations importantes disponibles.
🛡️ Firefighter Protection Equipment
Aucune mesure particulière n'est requise.
Accidental Release Measures & Spill Response
Emergency spill cleanup procedures, containment methods, and environmental protection
🌍 Environmental Precautions
Aucune mesure particulière n'est requise.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Safe Handling & Storage Procedures
Industrial handling precautions, storage conditions, and workplace safety requirements
⚠️ Handling Precautions
• Tenir les récipients hermétiquement fermés.
• Eviter la formation de poussière.
• En cas de formation de poussière, prévoir une aspiration.
🏪 Storage Conditions
• Stocker au frais et au sec dans des fûts bien fermés.
🔥 Fire Prevention Measures
Aucune mesure particulière n'est requise.
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
🏭 Engineering Controls
Sans autre indication, voir point 7.
🧤 Hand Protection
Gants de protection. Matériau des gants Gants de coton imprégnés avec du nitrile
👁️ Eye Protection
Lunettes de protection.
😷 Respiratory Protection
N'est pas nécessaire si la pièce dispose d'une bonne ventilation. Filtre respiratoire court terme : Filtre P2. En cas d'exposition faible ou de courte durée, utiliser un filtre respiratoire; en cas d'exposition intense ou durable, utiliser un appareil respiratoire autonome.
🦺 Skin/Body Protection
Vêtements de travail protecteurs.
Chemical Stability & Reactivity Data
Chemical stability, hazardous reactions, and incompatible materials information
✅ Chemical Stability
Pas de décomposition en cas d'usage conforme.
⚗️ Reactivity
Pas d'autres informations importantes disponibles.
⚠️ Hazardous Reactions
Réactions aux acides
🚫 Conditions to Avoid
Pas d'autres informations importantes disponibles.
🧪 Incompatible Materials
Pas d'autres informations importantes disponibles.
💨 Hazardous Decomposition Products
Pas de produits de décomposition dangereux connus
Ecological Information & Environmental Impact
Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data
🌱 Toxicité
🌱 Persistance et dégradabilité
🌱 Potentiel de bioaccumulation
🌱 Mobilité dans le sol
🌱 Résultats des évaluations PBT et VPVB
🌱 Autres effets néfastes
🌱 Autres indications écologiques
Waste Disposal & Treatment Methods
Waste disposal procedures, treatment methods, and regulatory compliance requirements
♻️ Waste Treatment Methods
Ce produit durcit 5 à 6 heures après l'adjonction d'eau et peut être ensuite éliminé sous forme de gravats.
🗂️ Product Disposal Recommendations
Evacuation conformément aux règlements de sécurité locaux/nationaux en vigueur
🏷️ Waste Classification Codes
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
📦 Proper Shipping Name
l'ONU néant
⚠️ Transport Hazard Class
néant
Regulatory Information & Compliance
Chemical regulations, safety assessments, and regulatory compliance status
📋 Regulatory Summary
Regulation (EC) No 1907/2006 (REACH) (Candidate List, Annexes XIV and XVII), Regulation (EC) No 1272/2008 (CLP), Directive 2004/42/CE (VOC), Directive 2012/18/UE.
❌ Chemical Safety Assessment
No chemical safety assessment has been performed for this substance.
ℹ️ Additional Regulatory Information
Ces indications sont fondées sur l'état actuel de nos connaissances, mais ne constituent pas une garantie quant aux propriétés du produit et ne donnent pas lieu à un rapport juridique contractuel.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Weber Égalisation?
The signal word for this substance is "danger".
What is the solubility of Weber Égalisation?
Durcit en cas de contact avec de l'eau.
What is Weber Égalisation used for?
Chimie de la construction
What are the hazard statements for Weber Égalisation?
This substance has 3 hazard statements: H315: Provoque une irritation cutanée. H318: Provoque de graves lésions des yeux. H317: Peut provoquer une allergie cutanée.
What is the melting point of Weber Égalisation?
The melting point is non déterminé and the boiling point is non applicable.