Product Name
ECO Sanitary Forte
Product Code
4003099 4003017 293121 293504

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Nettoyant sanitaires pour usage professionnel (AISE_SUMI_PW_8a_1_G // AISE_SUMI_PW_10_1 // AISE_SUMI_PW_13_1_G //AISE_SUMI_PW_19_1)

Overview

ECO Sanitary Forte commonly used nettoyant sanitaires pour usage professionnel (aise_sumi_pw_8a_1_g // aise_sumi_pw_10_1 // aise_sumi_pw_13_1_g //aise_sumi_pw_19_1).

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Skin Corr. Category 1A H314
Eye Dam. Category 1 H318

GHS Hazard Pictograms & Safety Symbols

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H314: Provoque de graves brûlures de la peau et de graves lésions des yeux.
  • H318: Provoque de graves lésions des yeux.

Precautionary Statements

  • P280: Porter des gants de protection, des vêtements de protection, un équipement de protection des yeux/du visage.
  • P301 + P330 + P331: EN CAS D'INGESTION: Rincer la bouche. NE PAS faire vomir.
  • P303 + P361 + P353: EN CAS DE CONTACT AVEC LA PEAU (ou les cheveux): Enlever immédiatement tous les vêtements contaminés. Rincer la peau à l'eau ou se doucher.
  • P305 + P351 + P338: EN CAS DE CONTACT AVEC LES YEUX: Rincer avec précaution à l'eau pendant plusieurs minutes. Enlever les lentilles de contact si la victime en porte et si elles peuvent être facilement enlevées. Continuer à rincer.
  • P310: Appeler immédiatement un CENTRE ANTIPOISON ou un médecin.
  • P501: Éliminer le contenu/récipient conformément à la réglementation locale / régionale / nationale / internationale.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Greenspeed company logo - Safety Data Sheet supplier organization

Greenspeed

manufacturer

P.O.Box 1250, 2280 CG Rijswijk (ZH), NL

NL

+31703458737

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+32 70 245 245

BE

Nationaal Vergiftigingen Informatie Centrum (NVIC)

+31 88 755 8000

NL

Uitsluitend bestemd om professionele hulpverleners te informeren bij acute vergiftigingen.

Emergency Contact

+ 33 (0)1 45 42 59 59

FR

Emergency Contact

(+352) 8002-5500

LU

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
N/A N/A 7% Hazardous
N/A N/A 7% Hazardous
N/A N/A 5% Hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

faire asseoir en position droite, apporter de l'air frais, laisser se reposer et emmener immédiatement à l'hôpital.

Symptoms:

céphalée, étourdissement, nausées, fatigue, inconscience

Skin Contact

retirer les vêtements contaminés, rincer la peau avec beaucoup d'eau et transporter immédiatement à l'hôpital.

Symptoms:

corrosif, rougeur, douleur, brûlures sévères

Eye Contact

rincer d'abord longuement avec beaucoup d'eau (enlever les lentilles de contact si cela est possible aisément) puis emmener chez un médecin.

Symptoms:

corrosif, rougeur, vision brouillée, douleur

Ingestion/Swallowing

laisser rincer la bouche, ne pas provoquer de vomissements et emmener immédiatement à l'hôpital.

Symptoms:

corrosif, respiration difficile, vomissements, ampoules sur les lèvres et la langue, douleur brûlante dans la bouche et la gorge, l'oesophage et l'estomac

Immediate Medical Attention Required

aucun

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
liquide
Critical Property
Physical State Data
liquid
State Under Standard Conditions
Not available
Appearance
Not available
Colour
rouge
Colour Intensity
Not available
Form
Not available
Odor
caractéristique
Odor Threshold
Not available
Ph
2,0
Melting Point
0 ℃
Critical Property
Boiling Point
78 ℃ - 100 ℃
Critical Property
Flash Point
Not available
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
2,000
Vapor Pressure
5 850 Pa
Vapor Density
Not available
Relative Density
1,0500 kg/l
Bulk Density
Not available
Density
Not available
Flammability
sans objet
Upper Explosive Limit
19,000 %
Lower Explosive Limit
3,000 %
Explosive Limits
Not available
Auto Ignition Temperature
370 ℃
Decomposition Temperature
Not available
Solubility
complètement soluble
Partition Coefficient
sans objet
Solubility In Water
complètement soluble
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
1,00 %
Metal Corrosion
Not available
Dynamic Viscosity
400 mPa.s
Kinematic Viscosity
381 mm2/s
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Le niveau de protection et les types de contrôles nécessaires varient en fonction des conditions d'exposition potentielles. Une ventilation adéquate doit être assurée afin que les limites d'exposition ne soient pas dépassées. Pour plus d'informations, consulter la section 7.

Hand Protection

manipuler avec des gants en Viton (EN 374). Délai de rupture > 480' Épaisseur 0,7 mm. Contrôler minutieusement les gants avant usage. Retirer les gants convenablement, sans toucher l'extérieur avec les mains nues. Le caractère approprié pour un poste de travail spécifique doit faire l'objet d'une concertation avec le fabricant des gants de protection. Laver et sécher vos mains.

Eye Protection

garder un flacon d'eau pour bains oculaires à portée de main. Lunettes de protection bien ajustées. Si de très importantes quantités de produit sont utilisées, porter un masque et une combinaison de protection.

Respiratory Protection

a utiliser avec une ventilation d'extraction suffissante. Aux endroits où il y a des risques respiratoires, utilisez le cas échéant un masque épurateur. Comme protection contre ces niveaux préjudiciables, utilisez le type ABEK.

Skin/Body Protection

vêtements imperméables. Le type d'équipement de protection dépend de la concentration et de la quantité de substances dangereuses sur le poste de travail en question.

Environmental Exposure Controls

Se conformer aux réglementations environnementales applicables limitant les rejets dans l'air, l'eau et le sol. Proteger l'environnement en appliquant des mesures de contrôle appropriées afin de prévenir ou de limiter les émissions. Pour plus d'informations, consulter les sections 6 et 13.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

3265

Proper Shipping Name

UN 3265 Liquide organique corrosif, acide, n.s.a., (mélange avec Acide lactique)

Transport Hazard Class

8

Packing Group

III

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for ECO Sanitary Forte?

The signal word for this substance is "danger".

What is the physical form of ECO Sanitary Forte?

ECO Sanitary Forte is a liquide with rouge color. It has caractéristique odor.

What is the solubility of ECO Sanitary Forte?

complètement soluble

What is ECO Sanitary Forte used for?

Nettoyant sanitaires pour usage professionnel (AISE_SUMI_PW_8a_1_G // AISE_SUMI_PW_10_1 // AISE_SUMI_PW_13_1_G //AISE_SUMI_PW_19_1)

What are the hazard statements for ECO Sanitary Forte?

This substance has 2 hazard statements: H314: Provoque de graves brûlures de la peau et de graves lésions des yeux. H318: Provoque de graves lésions des yeux.

What is the melting point of ECO Sanitary Forte?

The melting point is 0 ℃ and the boiling point is 78 ℃ - 100 ℃.