NextSDS Logo
20

205830 Foam Ex

NO SIGNAL WORD liquide SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
205830 Foam Ex

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Antimoussant (AISE_SUMI_PW_4_1; AISE_SUMI_PW_8a_2)

Overview

205830 Foam Ex commonly used antimoussant (aise_sumi_pw_4_1; aise_sumi_pw_8a_2).

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

BOMA company logo - Safety Data Sheet supplier organization

BOMA

manufacturer

Noorderlaan 131, B2030 Antwerpen

BE

003232313389

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+32 70 245 245

BE

Nationaal Vergiftigingen Informatie Centrum (NVIC)

+31 88 755 8000

NL

Uitsluitend bestemd om professionele hulpverleners te informeren bij acute vergiftigingen.

Emergency Contact

+33 (0)1 45 42 59 59

FR

Emergency Contact

(+352) 8002-5500

LU

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Composition Notes

Le texte intégral des phrases H mentionnées dans cette section figure à la section 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

en cas d'inconfort sévère ou persistant : déplacer à l'air frais et consulter un médecin

Symptoms:

aucun

Skin Contact

rincer à l'eau.

Symptoms:

aucun

Eye Contact

rincer d'abord avec beaucoup d'eau puis consulter un médecin si nécessaire.

Symptoms:

rougeur

Ingestion/Swallowing

rincer d'abord avec beaucoup d'eau, consulter un médecin si nécessaire.

Symptoms:

diarrhée, céphalée, crampes abdominales, somnolence, vomissements

Immediate Medical Attention Required

aucun

Medical Treatment

aucun

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Solubility
complètement soluble
Flammability
sans objet
Melting Point
0 ℃
Critical Property
Vapor Density
Not available
Density
Not available
Molecular Weight
Not available
Odor
caractéristique
Upper Explosive Limit
Not available
Solubility In Water
complètement soluble
Relative Density
1,0040 kg/l
Crystallisation Point
Not available
Odor Threshold
Not available
Cloud Point
Not available
Bulk Density
Not available
Relative Evaporation Rate
Not available
Vapor Pressure
Not available
Colour Intensity
Not available
Colour
incolore
Voc Content
0,000 g/l
Physical State
liquide
Critical Property
Flash Point
Not available
Partition Coefficient
Not available
Properties Status
Not available
Solubility In Fat
Not available
State Under Standard Conditions
Not available
Evaporation Rate
0,300
Physical State Data
liquid
Decomposition Temperature
Not available
Metal Corrosion
Not available
Lower Explosive Limit
Not available
Kinematic Viscosity
110 mm2/s
Appearance
Not available
Auto Ignition Temperature
Not available
Form
Not available
Dynamic Viscosity
110 mPa.s
Freezing Point
Not available
Boiling Point
100 °C - 100 ℃
Critical Property
Ph
7,1
Softening Point
Not available
Solidification Point
Not available
Explosive Limits
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Le niveau de protection et les types de contrôles nécessaires varient en fonction des conditions d'exposition potentielles. Une ventilation adéquate doit être assurée afin que les limites d'exposition ne soient pas dépassées. Pour plus d'informations, consulter la section 7.

Hand Protection

manipuler avec des gants en nitrile (EN 374). Délai de rupture > 480' Épaisseur 0,35 mm. Contrôler les gants minutieusement avant l'usage. Retirer les gants convenablement, sans toucher l'extérieur avec les mains nues. Le caractère approprié pour un poste de travail spécifique doit faire l'objet d'une concertation avec le fabricant des gants de protection. Laver et sécher vos mains.

Eye Protection

garder un flacon d'eau pour bains oculaires à portée de main. Lunettes de protection bien ajustées. Si de très importantes quantités de produit sont utilisées, porter un masque et une combinaison de protection.

Respiratory Protection

pas besoin de moyens de protection respiratoire. En cas d'exposition nocive, utilisez des masques antigaz du type ABEK. A utiliser éventuellement avec une ventilation d'extraction suffissante.

Skin/Body Protection

vêtements imperméables. Le type d'équipement de protection dépend de la concentration et de la quantité de substances dangereuses sur le poste de travail en question.

Environmental Exposure Controls

Se conformer aux réglementations environnementales applicables limitant les rejets dans l'air, l'eau et le sol. Protéger l'environnement en appliquant des mesures de contrôle appropriées afin de prévenir ou de limiter les émissions. Pour plus d'informations, consulter les sections 6 et 13.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Proper Shipping Name

ADR, IMDG, ICAO/IATA non réglementé

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for 205830 Foam Ex?

The signal word for this substance is "no signal word".

What is the physical form of 205830 Foam Ex?

205830 Foam Ex is a liquide with incolore color. It has caractéristique odor.

What is the solubility of 205830 Foam Ex?

complètement soluble

What is 205830 Foam Ex used for?

Antimoussant (AISE_SUMI_PW_4_1; AISE_SUMI_PW_8a_2)

What is the melting point of 205830 Foam Ex?

The melting point is 0 ℃ and the boiling point is 100 °C - 100 ℃.