NextSDS Logo
25

252005 Mark Off

DANGER liquide SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
252005 Mark Off
Product Code
252005

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
49DD-NCAF-D00K-QXDJ

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Détergent (AISE_SUMI_PW_8a_1_G // AISE_SUMI_PW_10_2_G // AISE_SUMI_PW_19_2_G)

Overview

252005 Mark Off commonly used détergent (aise_sumi_pw_8a_1_g // aise_sumi_pw_10_2_g // aise_sumi_pw_19_2_g).

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Acute Tox. Category 4 H302
Skin Irrit. Category 2 H315
Eye Dam. Category 1 H318
Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H302: Nocif en cas d'ingestion.
  • H315: Provoque une irritation cutanée.
  • H318: Provoque de graves lésions des yeux.
  • H412: Nocif pour les organismes aquatiques, entraîne des effets néfastes à long terme.

Precautionary Statements

  • P280: Porter des gants de protection, des vêtements de protection, un équipement de protection des yeux/du visage.
  • P302+P352: EN CAS DE CONTACT AVEC LA PEAU: Laver abondamment à l'eau et au savon.
  • P305+P351+P338: EN CAS DE CONTACT AVEC LES YEUX: Rincer avec précaution à l'eau pendant plusieurs minutes. Enlever les lentilles de contact si la victime en porte et si elles peuvent être facilement enlevées. Continuer à rincer.
  • P310: Appeler immédiatement un CENTRE ANTIPOISON ou un médecin.
  • P332+P313: En cas d'irritation cutanée: consulter un médecin.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

BOMA company logo - Safety Data Sheet supplier organization

BOMA

manufacturer

📍

Noorderlaan 131, B2030 Antwerpen

🌍

BE

📞

003232313389

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

+32 70 245 245

🌍

BE

Nationaal Vergiftigingen Informatie Centrum (NVIC)

📞

+31 88 755 8000

🌍

NL

💡

Uitsluitend bestemd om professionele hulpverleners te informeren bij acute vergiftigingen.

Emergency Contact

📞

+ 33 (0)1 45 42 59 59

🌍

FR

Emergency Contact

📞

(+352) 8002-5500

🌍

LU

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

en cas d'inconfort sévère ou persistant : déplacer à l'air frais et consulter un médecin

Symptoms:

aucun

🖐️ Skin Contact

rincer à l'eau.

Symptoms:

rougeur, douleur

👁️ Eye Contact

rincer d'abord avec beaucoup d'eau puis consulter un médecin si nécessaire.

Symptoms:

corrosif, rougeur, vision brouillée, douleur

🍽️ Ingestion/Swallowing

rincer d'abord avec beaucoup d'eau, consulter un médecin si nécessaire.

Symptoms:

diarrhée, céphalée, crampes abdominales, somnolence, vomissements

🚨 Immediate Medical Attention Required

aucun

Medical Treatment

aucun

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

📊 Relative Evaporation Rate
Not available
🔥 Flammability
sans objet
📊 Softening Point
Not available
📊 State Under Standard Conditions
Not available
📊 Decomposition Temperature
Not available
📊 Form
Not available
📊 Dynamic Viscosity
1 mPa.s
💧 Solubility
complètement soluble
🧪 Ph
5,0
📊 Relative Density
0,9100 kg/l
📊 Crystallisation Point
Not available
💨 Evaporation Rate
0,300
📊 Voc Content
65,08 %
📊 Solubility In Water
complètement soluble
📊 Vapor Density
sans objet
📊 Properties Status
Not available
🧊 Melting Point
Not available
📊 Molecular Weight
Not available
📊 Colour Intensity
Not available
📊 Partition Coefficient
sans objet
🔥 Flash Point
62 ℃
Critical Property
📊 Lower Explosive Limit
Not available
🎨 Colour
jaune
🧪 Physical State
liquide
Critical Property
💨 Vapor Pressure
Not available
📊 Auto Ignition Temperature
Not available
📊 Solubility In Fat
Not available
👃 Odor
caractéristique
📊 Cloud Point
Not available
📊 Upper Explosive Limit
Not available
📊 Freezing Point
Not available
⚖️ Density
Not available
📊 Kinematic Viscosity
1 mm2/s
📊 Bulk Density
Not available
📊 Odor Threshold
Not available
📊 Solidification Point
Not available
💨 Boiling Point
100 °C - 198 ℃
Critical Property
📊 Metal Corrosion
Not available
👁️ Appearance
Not available
📊 Explosive Limits
Not available
📊 Physical State Data
liquid

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Le niveau de protection et les types de contrôles nécessaires varient en fonction des conditions d'exposition potentielles. Une ventilation adéquate doit être assurée afin que les limites d'exposition ne soient pas dépassées. Pour plus d'informations, consulter la section 7.

🧤 Hand Protection

manipuler avec des gants en nitrile (EN 374). Délai de rupture > 480' Épaisseur 0,35 mm. Contrôler les gants minutieusement avant l'usage. Retirer les gants convenablement, sans toucher l'extérieur avec les mains nues. Le caractère approprié pour un poste de travail spécifique doit faire l'objet d'une concertation avec le fabricant des gants de protection. Laver et sécher vos mains.

👁️ Eye Protection

garder un flacon d'eau pour bains oculaires à portée de main. Lunettes de protection bien ajustées. Si de très importantes quantités de produit sont utilisées, porter un masque et une combinaison de protection.

😷 Respiratory Protection

a utiliser avec une ventilation d'extraction suffissante. Aux endroits où il y a des risques respiratoires, utilisez le cas échéant un masque épurateur. Comme protection contre ces niveaux préjudiciables, utilisez le type ABEK.

🦺 Skin/Body Protection

vêtements imperméables. Le type d'équipement de protection dépend de la concentration et de la quantité de substances dangereuses sur le poste de travail en question.

🌍 Environmental Exposure Controls

Se conformer aux réglementations environnementales applicables limitant les rejets dans l'air, l'eau et le sol. Protéger l'environnement en appliquant des mesures de contrôle appropriées afin de prévenir ou de limiter les émissions. Pour plus d'informations, consulter les sections 6 et 13.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

📦 Proper Shipping Name

ADR, IMDG, ICAO/IATA non réglementé

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for 252005 Mark Off?

The signal word for this substance is "danger".

What is the physical form of 252005 Mark Off?

252005 Mark Off is a liquide with jaune color. It has caractéristique odor.

What is the solubility of 252005 Mark Off?

complètement soluble

What is 252005 Mark Off used for?

Détergent (AISE_SUMI_PW_8a_1_G // AISE_SUMI_PW_10_2_G // AISE_SUMI_PW_19_2_G)

What are the hazard statements for 252005 Mark Off?

This substance has 4 hazard statements: H302: Nocif en cas d'ingestion. H315: Provoque une irritation cutanée. H318: Provoque de graves lésions des yeux. H412: Nocif pour les organismes aquatiques, entraîne des effets néfastes à long terme.