NextSDS Logo
PR

PROTECTION ANTI CORROSION SP 300 ML

DANGER Arosol contenant un gaz dissous SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
PROTECTION ANTI CORROSION SP 300 ML
Product Code
089315

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
WMN2-20RY-V002-6W1A

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Inhibiteur de corrosion; Utilisation professionnelle du produit
Uses Advised Against
Non applicable

Overview

PROTECTION ANTI CORROSION SP 300 ML commonly used inhibiteur de corrosion; utilisation professionnelle du produit.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Aerosol Category 1 H222
Press. Gas H229
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Aérosol extrêmement inflammable.
  • H229: Récipient sous pression: peut éclater sous l'effet de la chaleur.
  • H336: Peut provoquer somnolence ou vertiges.

Precautionary Statements

  • P210: Tenir à l'écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
  • P211: Ne pas vaporiser sur une flamme nue ou sur toute autre source d'ignition.
  • P251: Ne pas perforer, ni brûler, même après usage.
  • P261: Éviter de respirer les aérosols.
  • EN CAS D’INHALATION: transporter la personne à l’extérieur et la maintenir dans une position où elle peut confortablement respirer. Appeler un CENTRE ANTIPOISON/ un médecin en cas de malaise.
  • P410+P412: Protéger du rayonnement solaire. Ne pas exposer à une température supérieure à 50°C/122°F.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Wrth Belux N.V - S.A.

national supplier

📍

Everdongenlaan 29 2300 Turnhout

🌍

BE

📞

+32 (0)14 44 55 66

📠

+32 (0)14 44 55 67

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

+32 (0)70 245 245

🌍

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hydrocarbures, C9-C11, nalcanes, isoalcanes, cycliques, <2% aromatiques N/A 50-70% ⚠️ Hazardous
Distillats paraffiniques lgers (ptrole), hydrotraits
EC: 265-158-7
64742-55-8 20-30% ⚠️ Hazardous
Acide benznesulfonique, drivs dialkyles en C10-14, sels de calcium N/A 0.25-1% ⚠️ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

En cas d'inhalation, dplacer l'air frais. Faire appel une assistance mdicale si des symptmes apparaissent.

🖐️ Skin Contact

En cas de contact, rincer immdiatement la peau avec beaucoup d' eau. Enlever les vtements et les chaussures contamins. Faire appel une assistance mdicale. Laver les vtements avant de les remettre. Nettoyer mticuleusement les chaussures avant de les rutiliser.

Symptoms:

L'exposition rpte peut provoquer desschement ou gerures de la peau. Peut dclencher une raction allergique.

👁️ Eye Contact

Rincer les yeux l'eau par mesure de prcaution. Si une irritation se dveloppe et persiste, consulter un mdecin.

🍽️ Ingestion/Swallowing

Rincer soigneusement la bouche avec de l'eau. NE PAS faire vomir. Faire appel une assistance mdicale si des symptmes apparaissent.

🚨 Immediate Medical Attention Required

En cas d'accident ou de malaise, consulter immdiatement un mdecin. Faire appel une assistance mdicale si des symptmes apparaissent.

Medical Treatment

Effectuer un traitement symptomatique et d'appoint.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Arosol contenant un gaz dissous
Critical Property
📊 Physical State Data
Not available
📊 State Under Standard Conditions
Not available
👁️ Appearance
Not available
🎨 Colour
jaune, brun
📊 Colour Intensity
Not available
📊 Form
Not available
👃 Odor
lgre, odeur de ptrole
📊 Odor Threshold
Donne non disponible
🧪 Ph
Mlange de solvants ; dtermination de la valeur en pH impossible, pas de solution aqueuse
🧊 Melting Point
Donne non disponible
Critical Property
💨 Boiling Point
Non applicable
Critical Property
🔥 Flash Point
Non applicable
Critical Property
📊 Freezing Point
Donne non disponible
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Non applicable
💨 Vapor Pressure
Non applicable
📊 Vapor Density
Not available
📊 Relative Density
Not available
📊 Bulk Density
Not available
⚖️ Density
0,726 g/cm (20 C)
Critical Property
🔥 Flammability
Arosol extrmement inflammable.
📊 Upper Explosive Limit
Donne non disponible
📊 Lower Explosive Limit
Donne non disponible
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
Donne non disponible
📊 Decomposition Temperature
Donne non disponible
💧 Solubility
Not available
📊 Partition Coefficient
Non applicable
📊 Solubility In Water
insoluble
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
Not available
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
Non applicable
📊 Kinematic Viscosity
Non applicable
📊 Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Réduire au minimum les concentrations d'exposition au travail. Si une ventilation suffisante n'est pas disponible, utiliser avec une ventilation locale par aspiration. Si conseillé par l'évaluation du potentiel d'exposition local, utiliser uniquement dans un endroit équipé d'une ventilation par aspiration antidéflagrante.

🧤 Hand Protection

Matériel: Caoutchouc nitrile. Délai de rupture: >= 60 min. Épaisseur du gant: 1,1 mm. L'équipement doit être conforme à la norme EN NBN 374. Remarques: Le choix du type de gants de protection contre les produits chimiques doit être effectué en fonction de la concentration et de la quantité des substances dangereuses propres aux postes de travail. Dans le cas d'applications spéciales, il est recommandé de se renseigner auprès du fabricant de gants sur la résistance aux produits chimiques des gants de protection indiqués ci-dessus.

👁️ Eye Protection

Porter des lunettes de sécurité. L'équipement doit être conforme à la norme EN NBN 166.

😷 Respiratory Protection

Si une ventilation locale par aspiration adéquate n'est pas disponible ou si l'évaluation de l'exposition démontre des expositions au-delà des lignes directrices recommandées, utiliser une protection respiratoire. L'équipement doit être conforme à la norme EN NBN 137. Type de filtre: Appareil respiratoire autonome.

🦺 Skin/Body Protection

Si l'évaluation démontre qu'il existe un risque d'atmosphères explosives ou de feux instantanés, utiliser un revêtement protecteur antistatique retardateur de flamme.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN 1950

⚠️ Transport Hazard Class

22 / 27

📋 Packing Group

Non rglement

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for PROTECTION ANTI CORROSION SP 300 ML?

The signal word for this substance is "danger".

What is the physical form of PROTECTION ANTI CORROSION SP 300 ML?

PROTECTION ANTI CORROSION SP 300 ML is a arosol contenant un gaz dissous with jaune, brun color. It has lgre, odeur de ptrole odor.

What is PROTECTION ANTI CORROSION SP 300 ML used for?

Inhibiteur de corrosion; Utilisation professionnelle du produit

What are the hazard statements for PROTECTION ANTI CORROSION SP 300 ML?

This substance has 3 hazard statements: H222: Aérosol extrêmement inflammable. H229: Récipient sous pression: peut éclater sous l'effet de la chaleur. H336: Peut provoquer somnolence ou vertiges.

What is the melting point of PROTECTION ANTI CORROSION SP 300 ML?

The melting point is Donne non disponible and the boiling point is Non applicable.