NextSDS Logo
AZ

AZOLLA ZS 68

NO SIGNAL WORD Liquide. [limpide] SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
AZOLLA ZS 68

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Huile hydraulique

Overview

AZOLLA ZS 68 commonly used huile hydraulique.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Pas de mention d'avertissement.)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

TotalEnergies Lubrifiants

global supplier

📍

562 Avenue du Parc de L'ile 92029 Nanterre Cedex FRANCE

🌍

FR

📞

+33 (0)1 41 35 40 00

📠

+33 (0)1 41 35 84 71

TotalEnergies Marketing Belgium

national supplier

📍

Anspachlaan 1, bus 2 / Boulevard anspach 1, bote 2 1000 Brussel/Bruxelles Belgi/Belgique

🌍

BE

📞

+32 (0)22 889 933

📠

+32 (0)22 883 260

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Centre antipoison

📞

+32 70 245 245

🌍

BE

Fournisseur (info produit)

📞

+44 1235239670

🌍

GB

SOS TotalEnergies Marketing Belgium (transport)

📞

+32 78 15 51 51

🌍

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Huile minrale d'origine pétrolière. Produit à base d'huiles minérales dont l'extrait DMSO est inférieur à 3%, selon la méthode IP 346.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
distillats paraffiniques lourds (pétrole), hydrotraités
EC: 265-157-1
64742-54-7 90% ✓ Non-hazardous

Composition Notes

Dans l'état actuel des connaissances du fournisseur et dans les concentrations d'application, aucun autre ingrédient présent n'est classé comme dangereux pour la santé ou l'environnement, ni comme PBT ou vPvB, ni comme substance de degré de préoccupation équivalent, ni soumis à une limite d'exposition professionnelle et donc nécessiterait de figurer dans cette section.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Transporter la victime l'extrieur et la maintenir au repos dans une position o elle peut confortablement respirer. Consulter un mdecin si des symptmes se dveloppent.

🖐️ Skin Contact

Laver soigneusement la peau au savon et l'eau ou utiliser un nettoyant cutan reconnu. Retirer les vtements et les chaussures contamins. Consulter un mdecin si des symptmes se dveloppent.

Symptoms:

Les symptmes nfastes peuvent ventuellement comprendre ce qui suit: irritation, scheresse, gerure

👁️ Eye Contact

Rincer immdiatement les yeux grande eau, en soulevant de temps en temps les paupires suprieures et infrieures. Vrifier si la victime porte des verres de contact et dans ce cas, les lui enlever. En cas d'irritation, consulter un mdecin.

🍽️ Ingestion/Swallowing

Rincez la bouche avec de l'eau. Ne pas faire vomir sauf indication contraire manant du personnel mdical. Consulter un mdecin si des symptmes se dveloppent.

🚨 Immediate Medical Attention Required

Contacter immdiatement un spcialiste pour le traitement des intoxications, si de grandes quantits ont t ingres ou inhales.

Medical Treatment

Traitement symptomatique requis. Pas de traitement particulier.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Liquide. [limpide]
Critical Property
📊 Physical State Data
liquid
📊 State Under Standard Conditions
Not available
👁️ Appearance
Not available
🎨 Colour
Jaune.
📊 Colour Intensity
Not available
📊 Form
Not available
👃 Odor
Caractristique.
📊 Odor Threshold
Not available
🧪 Ph
Non applicable.
🧊 Melting Point
Mesure techniquement impossible
Critical Property
💨 Boiling Point
>316C [ISO 3405]
Critical Property
🔥 Flash Point
Vase ouvert: 210C [Coupe ouverte Cleveland]
Critical Property
📊 Freezing Point
Mesure techniquement impossible
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Not available
💨 Vapor Pressure
<0.013 kPa [temprature ambiante]
📊 Vapor Density
>2 [Air = 1]
📊 Relative Density
0.862 [ISO 12185]
📊 Bulk Density
Not available
⚖️ Density
0.862 g/cm [15C] [ISO 12185]
Critical Property
🔥 Flammability
Non applicable.
📊 Upper Explosive Limit
Seuil maximal: 7%
📊 Lower Explosive Limit
Seuil minimal: 0.9%
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
>210C [ASTM E 659]
📊 Decomposition Temperature
Non applicable.
💧 Solubility
Le produit n'est pas soluble (dans l'eau). Support eau Rsultat Non soluble. Miscible leau : Non.
📊 Partition Coefficient
Non applicable.
📊 Solubility In Water
Non soluble
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
Not available
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
Dynamique (temprature ambiante): Non disponible.
📊 Kinematic Viscosity
Cinmatique (temprature ambiante): Non disponible. Cinmatique (40C): 61.4 74.6 mm [2] /s [ISO 3104]
📊 Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Une bonne ventilation générale devrait être suffisante pour contrôler l'exposition du technicien aux contaminants en suspension dans l'air.

🧤 Hand Protection

Le port de gants imperméables et résistants aux produits chimiques conformes à une norme approuvée, est obligatoire en tout temps lors de la manutention de produits chimiques si une évaluation des risques le préconise. Gants résistants aux hydrocarbures caoutchouc nitrile Caoutchouc fluor Veuillez observer les instructions concernant la perméabilité et le temps de pénétration qui sont fournies par le fournisseur de gants. Prendre également en considération les conditions locales spécifiques dans lesquelles le produit est utilisé, telles que le risque de coupures, d'abrasion et le temps de contact. Lors de contact prolongé avec le produit, il est recommandé de porter des gants conformes aux normes ISO 21420 et EN 374, présentant une durée de protection de 480 minutes et une épaisseur de 0,38 mm au minimum. Ces valeurs sont données à titre indicatif. Le niveau de protection est assuré par le matériau du gant, ses caractéristiques techniques, sa résistance aux produits chimiques utilisés, la conformité de son utilisation et par sa fréquence de remplacement

👁️ Eye Protection

En cas de contact par projection: lunettes de sécurité avec protections latérales, EN 166.

😷 Respiratory Protection

Aucun(e)(s) dans les conditions normales d'utilisation. Si ceci ne suffit pas à maintenir une exposition inférieure à la VLEP, une protection respiratoire appropriée doit être utilisée (Type A/P1).

🦺 Skin/Body Protection

L'équipement de protection personnel pour le corps devra être choisi en fonction de la tâche à réaliser ainsi que des risques encourus, et il est recommandé de le faire valider par un spécialiste avant de procéder à la manipulation du produit. Chaussures ou bottes de sécurité antidérapantes

🌍 Environmental Exposure Controls

Il importe de tester les émissions provenant des systèmes de ventilation ou du matériel de fabrication pour vous assurer qu'elles sont conformes aux exigences de la législation sur la protection de l'environnement. Dans certains cas, il sera nécessaire d'équiper le matériel de fabrication d'un épurateur de gaz ou d'un filtre ou de le modifier techniquement afin de réduire les émissions des niveaux acceptables.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

📦 Proper Shipping Name

Non réglement.

⚠️ Transport Hazard Class

Non réglement.

📋 Packing Group

Non réglement.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for AZOLLA ZS 68?

The signal word for this substance is "no signal word".

What is the physical form of AZOLLA ZS 68?

AZOLLA ZS 68 is a liquide. [limpide] with jaune. color. It has caractristique. odor.

What is the solubility of AZOLLA ZS 68?

Le produit n'est pas soluble (dans l'eau). Support eau Rsultat Non soluble. Miscible leau : Non.

What is AZOLLA ZS 68 used for?

Huile hydraulique

What is the melting point of AZOLLA ZS 68?

The melting point is Mesure techniquement impossible and the boiling point is >316C [ISO 3405].