NextSDS Logo
Safety Data Sheet FR

FLOC-PAM 2547

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
FLOC-PAM 2547
Product Form
Mlange

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Agent de procd pour applications industrielles.

Uses advised against

Aucun(e).

Manufacturers & Suppliers

S

SNF-WATER bvba-sprl

Drie Eikenstraat 661 B-2650 - Edegem Belgium

+32 3 354 45 22

Emergency Contacts

Emergency Contact

+33 477 86 87 25

24h/24

Centre antipoison

070/245.245

7 jours/7; 24 heures/24

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C12-C15, n-alkanes, isoalkanes, cyclics, <2% aromatics EC: 920-107-4 --- 20 - 30% No
Isotridecanol, thoxyl --- 5% No
Acide adipique EC: 204-673-3 --- 2% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Amener la victime l'air libre.

Skin contact

Laver immdiatement au savon et abondamment l'eau en enlevant les vtements contamins et les chaussures. En cas d'irritation persistante de la peau, consulter un mdecin.

Eye contact

Rincer immdiatement et abondamment l'eau, y compris sous les paupires, pendant au moins 15 minutes. Faire immdiatement appel une assistance mdicale.

Ingestion

Se rincer la bouche l'eau. Ne PAS faire vomir. Appeler immdiatement un mdecin ou un centre AntiPoison.

Immediate Medical Attention

Faire immdiatement appel une assistance mdicale (pour les yeux). Appeler immdiatement un mdecin ou un centre AntiPoison (pour l'ingestion).

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Assurer une ventilation adéquate, surtout dans les endroits clos. Aspiration locale en cas de brouillards, la ventilation naturelle est suffisante en l'absence de brouillards.

Hands

Gants en PVC ou autre matière plastique.

Eyes

Lunettes de sécurité avec protections latérales.

Respiratory

Aucun équipement de protection respiratoire individuel n'est normalement nécessaire.

Skin/Body

Porter une combinaison et/ou un tablier et des chaussures en caoutchouc si un contact physique peut advenir.

Environmental

Ne pas laisser le produit s'écouler de manière incontrôlée dans l'environnement.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquide.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquide.
Colour
---
Colour Intensity
---
Form
---
Odor
Aliphatique
Odor Threshold
Donne non disponible.
Ph
4-6 @5 g/L
Melting Point
< 5
Boiling Point
> 100
Flash Point
N'a pas de point d'clair.
Freezing Point
< 5
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Donne non disponible.
Vapor Pressure
2.3 kPa @ 20
Vapor Density
0.804 g/litre @ 20
Relative Density
1.0 - 1.1
Bulk Density
---
Density
---
Flammability
Non applicable.
Upper Explosive Limit
Ne devrait pas crer des atmosphres explosives.
Lower Explosive Limit
Ne devrait pas crer des atmosphres explosives.
Explosive Limits
---
Auto Ignition Temperature
Non applicable
Decomposition Temperature
> 150
Solubility
compltement miscible
Partition Coefficient
Non applicable.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
> 20.5 mm2/s @ 40
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for FLOC-PAM 2547?

The signal word is no signal word.

What is the physical form of FLOC-PAM 2547?

FLOC-PAM 2547 is a liquide. appearing as liquide. . It has aliphatique odor.

What is the solubility of FLOC-PAM 2547?

compltement miscible

What is FLOC-PAM 2547 used for?

Agent de procd pour applications industrielles.

What is the melting point of FLOC-PAM 2547?

The melting point is < 5 and the boiling point is > 100.

Compliance Scanner

Scan your compliance