NextSDS Logo
So

Soudaseal 250XF

NO SIGNAL WORD Pte SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Soudaseal 250XF

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Produit d'tanchit
Uses Advised Against
Aucune utilisation dconseille connue

Overview

Soudaseal 250XF commonly used produit d'tanchit.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

SOUDAL N.V.

global supplier

๐Ÿ“

Everdongenlaan 18-20 B-2300 Turnhout

๐ŸŒ

BE

๐Ÿ“ž

+32 14 42 42 31

๐Ÿ“ 

+32 14 42 65 14

SOUDAL N.V.

manufacturer

๐Ÿ“

Everdongenlaan 18-20 B-2300 Turnhout

๐ŸŒ

BE

๐Ÿ“ž

+32 14 42 42 31

๐Ÿ“ 

+32 14 42 65 14

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

BIG

๐Ÿ“ž

+32 14 58 45 45

๐ŸŒ

BE

๐Ÿ•’

24h/24h

๐Ÿ—ฃ๏ธ

Languages: EN, FR, DE, NL

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
trimthoxyvinylsilane
EC: 220-449-8
2768-02-7 1-10% โš ๏ธ Hazardous
[[3,5-bis(1,1-dimthylthyl)-4- hydroxyphnyl]mthyl]butylmalonate de bis(1,2,2,6,6- pentamthyl-4-pipridyle)
EC: 264-513-3
63843-89-0 0.1-0.25% โš ๏ธ Hazardous
distillats paraffiniques lgers (ptrole), hydrotraits
EC: 265-158-7
64742-55-8 1-10% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Emmener la victime ร  l'air frais. Troubles respiratoires: consulter mรฉdecin/service mรฉdical.

Symptoms:

Pas d'effets connus.

๐Ÿ–๏ธ Skin Contact

Rincer ร  l'eau. Du savon peut รชtre utilisรฉ. Ne pas utiliser des produits (chimiques) neutralisants sans avis mรฉdical. Consulter un mรฉdecin si l'irritation

Symptoms:

Pas d'effets connus.

๐Ÿ‘๏ธ Eye Contact

Rincer ร  l'eau. Enlever les lentilles de contact si la victime en porte et si elles peuvent รชtre facilement enlevรฉes. Continuer rincer. Ne pas utiliser des produits (chimiques) neutralisants sans avis mรฉdical. Consulter un ophtalmologue si l'irritation persiste.

Symptoms:

Pas d'effets connus.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rincer la bouche ร  l'eau. Ne pas utiliser des produits (chimiques) neutralisants sans avis mรฉdical. Consulter un mรฉdecin/le service mรฉdical en cas de malaise.

Symptoms:

Pas d'effets connus.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Pte
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Couleurs varient en fonction de la composition
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Odeur caractristique
๐Ÿ“Š Odor Threshold
Aucun renseignement disponible
๐Ÿงช Ph
Aucun renseignement disponible
๐ŸงŠ Melting Point
Aucun renseignement disponible
Critical Property
๐Ÿ’จ Boiling Point
Aucun renseignement disponible
Critical Property
๐Ÿ”ฅ Flash Point
Aucun renseignement disponible
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Aucun renseignement disponible
๐Ÿ’จ Vapor Pressure
Aucun renseignement disponible
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
1.49 ; 20
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1490 kg/m3 ; 20
Critical Property
๐Ÿ”ฅ Flammability
Ininflammable
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Aucun renseignement disponible
๐Ÿ“Š Decomposition Temperature
Aucun renseignement disponible
๐Ÿ’ง Solubility
Aucun renseignement disponible
๐Ÿ“Š Partition Coefficient
Sans objet (mlange)
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Aucun renseignement disponible
๐Ÿ“Š Kinematic Viscosity
Aucun renseignement disponible
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Tenir l'รฉcart de flammes nues/la chaleur. Faire les travaux en plein air/sous aspiration locale/ventilation ou protection respiratoire.

๐Ÿงค Hand Protection

Gants de protection contre les produits chimiques (EN374).

๐Ÿ‘๏ธ Eye Protection

Protection des yeux non requise dans des conditions normales.

๐Ÿ˜ท Respiratory Protection

Protection respiratoire non requise dans des conditions normales.

๐Ÿฆบ Skin/Body Protection

Vรชtements de protection.

๐ŸŒ Environmental Exposure Controls

Voir points 6.2, 6.3 et 13

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Soudaseal 250XF?

The signal word for this substance is "no signal word".

What is the physical form of Soudaseal 250XF?

Soudaseal 250XF is a pte with couleurs varient en fonction de la composition color. It has odeur caractristique odor.

What is the solubility of Soudaseal 250XF?

Aucun renseignement disponible

What is Soudaseal 250XF used for?

Produit d'tanchit

What is the melting point of Soudaseal 250XF?

The melting point is Aucun renseignement disponible and the boiling point is Aucun renseignement disponible.