NextSDS Logo
KI

KIMBERLY-CLARK PROFESSIONAL* MELODIE Recharge de parfum

WARNING liquide SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
KIMBERLY-CLARK PROFESSIONAL* MELODIE Recharge de parfum
Product Code
6135

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Diffuseur de parfum

Overview

KIMBERLY-CLARK PROFESSIONAL* MELODIE Recharge de parfum is a clair substance commonly used diffuseur de parfum.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Attention)

Hazard Classifications

Flam. Liq. Category 3 H226
Eye Irrit. Category 2 H319

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Liquide et vapeurs inflammables.
  • H319: Provoque une svre irritation des yeux.

Precautionary Statements

  • P210: Tenir lcart de la chaleur/des tincelles/des flammes nues/des surfaces chaudes. Ne pas fumer.
  • P305 + P351 + P338: EN CAS DE CONTACT AVEC LES YEUX: rincer avec prcaution l'eau pendant plusieurs minutes. Enlever les lentilles de contact si la victime en porte et si elles peuvent tre facilement enleves. Continuer rincer.
  • P337 + P313: Si l'irritation oculaire persiste: consulter un mdecin.
  • P370 + P378: En cas d'incendie: utiliser du sable sec, de la poudre chimique sche ou de la mousse rsistant l'alcool pour l'extinction.
  • P403 + P235: Stocker dans un endroit bien ventil. Tenir au frais.
  • P501: liminer le contenu/rcipient dans une installation d'limination des dchets agre.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Kimberly-Clark Europe Limited

global supplier

40 London Road Reigate Surrey RH2 9QP Royaume Uni

GB

+44 1737 736000

+44 1737 736670

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+44 1865 407333

GB

24 heures sur 24, 7 jours sur 7

Institut national de recherche et de scurit (INRS)

+33 1 40 44 30 00

FR

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
DIACETONE-ALCOOL
EC: 200-661-7
67-63-0 Not specified Hazardous
4-tert-Butylcyclohexyl acetate
EC: 250-954-9
32210-23-4 Not specified Hazardous
Linalol
EC: 201-134-4
78-70-6 Not specified Hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Skin Contact

Laver au savon avec une grande quantité d'eau.

Symptoms:

irritation de la peau

Eye Contact

Rincer immédiatement l'oeil (les yeux) à grande eau.

Ingestion/Swallowing

Ne PAS faire vomir.

Immediate Medical Attention Required

Si l'irritation de la peau persiste, appeler un médecin.

Medical Treatment

Pas d'information disponible.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
liquide
Critical Property
Physical State Data
liquid
State Under Standard Conditions
Not available
Appearance
clair
Colour
clair
Colour Intensity
Not available
Form
Not available
Odor
plaisante
Odor Threshold
Not available
Ph
5.75
Melting Point
Not available
Boiling Point
100 C
Critical Property
Flash Point
35 C
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Not available
Vapor Pressure
Not available
Vapor Density
Not available
Relative Density
0.98
Bulk Density
Not available
Density
0.98 gcm3 (23 C)
Critical Property
Flammability
Not available
Upper Explosive Limit
12 % (v)
Lower Explosive Limit
2 % (v)
Explosive Limits
Not available
Auto Ignition Temperature
Not available
Decomposition Temperature
Not available
Solubility
Not available
Partition Coefficient
Not available
Solubility In Water
soluble
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
Not available
Kinematic Viscosity
Not available
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

En cas de contact prolong ou rpt, utiliser des gants de protection.

Eye Protection

inutile dans les conditions normales d'utilisation

Respiratory Protection

Inutile dans les conditions normales d'utilisation.

Skin/Body Protection

inutile dans les conditions normales d'utilisation

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

ADR Transport Precautions

Non applicable

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for KIMBERLY-CLARK PROFESSIONAL* MELODIE Recharge de parfum?

The signal word for this substance is "warning".

What is the physical form of KIMBERLY-CLARK PROFESSIONAL* MELODIE Recharge de parfum?

KIMBERLY-CLARK PROFESSIONAL* MELODIE Recharge de parfum is a liquide appearing as clair with clair color. It has plaisante odor.

What is KIMBERLY-CLARK PROFESSIONAL* MELODIE Recharge de parfum used for?

Diffuseur de parfum

What are the hazard statements for KIMBERLY-CLARK PROFESSIONAL* MELODIE Recharge de parfum?

This substance has 2 hazard statements: H226: Liquide et vapeurs inflammables. H319: Provoque une svre irritation des yeux.