NextSDS Logo
FP

FPFILR-AP-310ML

NO SIGNAL WORD pte SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
FPFILR-AP-310ML
Product Code
0893306314

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Revtements monocomposants fonction spciale, Ignifugeant Utilisation professionnelle du produit

Overview

FPFILR-AP-310ML is a pte substance commonly used revtements monocomposants fonction spciale, ignifugeant utilisation professionnelle du produit.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Wrth Belux N.V - S.A.

national supplier

๐Ÿ“

Everdongenlaan 29 2300 Turnhout

๐ŸŒ

BE

๐Ÿ“ž

+32 (0)14 44 55 66

๐Ÿ“ 

+32 (0)14 44 55 67

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+32 (0)70 245 245

๐ŸŒ

BE

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

En cas d'inhalation, dplacer l'air frais.

๐Ÿ–๏ธ Skin Contact

Laver l'eau et au savon par prcaution.

๐Ÿ‘๏ธ Eye Contact

Rincer les yeux l'eau par mesure de prcaution.

Symptoms:

irritation

๐Ÿฝ๏ธ Ingestion/Swallowing

Rincer soigneusement la bouche avec de l'eau.

Medical Treatment

Effectuer un traitement symptomatique et d'appoint.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
pte
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
pte
๐ŸŽจ Colour
blanc
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
caractristique
๐Ÿ“Š Odor Threshold
Donne non disponible
๐Ÿงช Ph
7,15 - 7,25
๐ŸงŠ Melting Point
Donne non disponible
Critical Property
๐Ÿ’จ Boiling Point
Donne non disponible
Critical Property
๐Ÿ”ฅ Flash Point
Bout avant le flash
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Donne non disponible
๐Ÿ’จ Vapor Pressure
Donne non disponible
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1,27 - 1,41 g/cm (20 C)
Critical Property
๐Ÿ”ฅ Flammability
Inflammabilit (solide, gaz) : Non applicable; Inflammabilit (liquides) : Ne brle pas
๐Ÿ“Š Upper Explosive Limit
Donne non disponible
๐Ÿ“Š Lower Explosive Limit
Donne non disponible
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Donne non disponible
๐Ÿ“Š Decomposition Temperature
Donne non disponible
๐Ÿ’ง Solubility
soluble
๐Ÿ“Š Partition Coefficient
Non applicable
๐Ÿ“Š Solubility In Water
Donne non disponible
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
12.000 - 24.000 mPa.s (20 C)
๐Ÿ“Š Kinematic Viscosity
Donne non disponible
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Assurer une ventilation adquate, surtout dans les endroits clos. Rduire au minimum les concentrations d'exposition au travail.

๐Ÿงค Hand Protection

Matriel : caoutchouc butyle. Dlait de rupture : - 480 min. Directive : DIN EN 374. Le choix du type de gants de protection contre les produits chimiques doit tre effectu en fonction de la concentration et de la quantit des substances dangereuses propres aux postes de travail. Dans le cas d'applications spciales, il est recommand de se renseigner auprs du fabricant de gants sur la rsistance aux produits chimiques des gants de protection indiqus ci-dessus.

๐Ÿ‘๏ธ Eye Protection

Lunettes de scurit. Veuillez toujours porter des lunettes de protection lorsqu'on ne peut exclure un risque de contact du produit avec les yeux par inadvertance. L'quipement doit tre conforme la norme EN NBN 166.

๐Ÿ˜ท Respiratory Protection

Aucun quipement de protection respiratoire individuel n'est normalement ncessaire.

๐Ÿฆบ Skin/Body Protection

Nettoyer soigneusement la peau aprs tout contact avec le produit.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for FPFILR-AP-310ML?

The signal word for this substance is "no signal word".

What is the physical form of FPFILR-AP-310ML?

FPFILR-AP-310ML is a pte appearing as pte with blanc color. It has caractristique odor.

What is the solubility of FPFILR-AP-310ML?

soluble

What is FPFILR-AP-310ML used for?

Revtements monocomposants fonction spciale, Ignifugeant Utilisation professionnelle du produit

What is the melting point of FPFILR-AP-310ML?

The melting point is Donne non disponible and the boiling point is Donne non disponible.