NextSDS Logo
FI

FIXOLID

WARNING Liquide SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
FIXOLID
Product Form
Mélange

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Peinture
Uses Advised Against
Pas d'informations complémentaires disponibles

Overview

FIXOLID commonly used peinture.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Attention)

Hazard Classifications

Flam. Liq. Category 3 H226
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Liquide et vapeurs inflammables.
  • H336: Peut provoquer somnolence ou vertiges.

Precautionary Statements

  • P210: Tenir à l’écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d’inflammation. Ne pas fumer.
  • P261: Éviter de respirer les vapeurs, brouillards.
  • P312: Appeler un médecin, un CENTRE ANTIPOISON en cas de malaise.
  • P403 + P233: Stocker dans un endroit bien ventilé. Maintenir le récipient fermé de manière étanche.
  • P501: Éliminer le contenu et le récipient dans un centre de collecte de déchets dangereux ou spéciaux, conformément à la réglementation locale, régionale, nationale et/ou internationale.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

FILAgroup France

undefined

route de Marson, 64 51240 Saint Germain la Ville France

FR

03.26.69.26.26

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

ORFILA

+33 (0)1 45 42 59 59

FR

24 heures sur 24 et 7 jours sur 7

Ce numéro permet d’obtenir les coordonnées de tous les centres Anti-poison Français. Ces centres anti-poison et de toxicovigilance fournissent une aide médicale gratuite (hors coût d’appel), 24 heures sur 24 et 7 jours sur 7.

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Acétate de n-butyle
EC: 204-658-1
123-86-4 51-56% Hazardous
Dioxyde de titane
EC: 236-675-5
13463-67-7 0.2-7.5% Non-hazardous
Noir de carbone
EC: 215-609-9
1333-86-4 5% Non-hazardous
Toluène
EC: 203-625-9
108-88-3 0.7-0.8% Hazardous

Additional Information

Texte intgral des mentions H et EUH : voir rubrique 16

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Retirer le sujet de la zone contaminée et l'amener à l'air frais. Consulter un médecin en cas de malaise.

Symptoms:

Peut provoquer somnolence ou vertiges.

Skin Contact

Laver à l'eau et au savon par précaution. En cas d’irritation cutanée: consulter un médecin.

Symptoms:

Un contact prolongé ou répété peut provoquer un dessèchement ou des gerçures de la peau.

Eye Contact

Rincer les yeux à l'eau par mesure de précaution. En cas de rougeur ou irritation, appeler un médecin.

Symptoms:

rougeur ou irritation

Ingestion/Swallowing

Rincer la bouche à l'eau. Ne pas faire vomir. Consulter un médecin.

Medical Treatment

Traitement symptomatique.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Eau pulvérisée. Poudre sèche. Dioxyde de carbone (CO2). Mousse.

Unsuitable Extinguishing Media

Ne pas utiliser un fort courant d'eau.

Specific Fire Hazards

Danger d'incendie : Liquide et vapeurs inflammables. Danger d'explosion : Peut former des mélanges vapeur-air inflammables/explosifs.

Fire Fighting Instructions

Refroidir l'eau pulvérisée les récipients exposés à la chaleur. Endiguer et contenir les fluides d'extinction.

Firefighter Protection Equipment

Ne pas intervenir sans un équipement de protection adapt. Appareil de protection respiratoire autonome isolant. Protection complète du corps.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Eviter le contact avec la peau et les yeux. Ne pas respirer les vapeurs.

Large Spill Procedures

Intervention limitée au personnel qualifié muni des protections appropriées.

Environmental Precautions

Endiguer et contenir l'épandage. Éviter le rejet dans l'environnement.

Cleanup Methods

Laver le reliquat non récupérable à grande eau.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Colour Intensity
Not available
Dynamic Viscosity
Not available
Evaporation Rate
Not available
Freezing Point
Pas disponible
Melting Point
Pas disponible
Critical Property
Decomposition Temperature
Pas disponible
Vapor Density
Not available
Relative Density
1 – 1,2
Flash Point
< 60 °C
Critical Property
Solidification Point
Not available
Crystallisation Point
Not available
Metal Corrosion
Not available
Solubility
Peu soluble dans l'eau.
Physical State Data
liquid
Relative Evaporation Rate
Not available
Voc Content
47,1 %
Flammability
Liquide et vapeurs inflammables.
Kinematic Viscosity
> 900 mm²/s (s) (20°C)
Solubility In Water
Not available
Boiling Point
> 100 °C
Critical Property
Softening Point
Not available
Odor Threshold
Non déterminé
Molecular Weight
Not available
Partition Coefficient
Pas disponible
Auto Ignition Temperature
Pas disponible
Physical State
Liquide
Critical Property
State Under Standard Conditions
Not available
Lower Explosive Limit
Pas disponible
Upper Explosive Limit
Pas disponible
Appearance
Not available
Form
Not available
Properties Status
Not available
Solubility In Fat
Not available
Vapor Pressure
Pas disponible
Ph
Pas disponible
Bulk Density
Not available
Colour
Variable.
Density
Pas disponible
Critical Property
Explosive Limits
Not available
Odor
Acétate de n-butyle.
Cloud Point
Not available
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Assurer une bonne ventilation du poste de travail.

Eviter le contact avec la peau et les yeux.

Ne pas respirer les vapeurs.

Eviter l'accumulation de charges lectrostatiques.

Mise la terre/liaison quipotentielle du rcipient et du matriel de rception.

Ne pas fumer.

Pas de flammes, pas d'tincelles.

Supprimer toute source d'ignition.

Utiliser un appareillage antidflagrant.

Storage Conditions

Conserver dans un endroit frais et bien ventil l'cart de la chaleur.

Protger du rayonnement solaire.

Tenir l'cart de sources d'ignition.

Conserver le rcipient bien ferm.

General Hygiene Measures

Ne pas boire, manger ou fumer sur le lieu de travail. Se laver les mains aprs toute manipulation.

Fire Prevention Measures

Ne pas fumer. Pas de flammes, pas d'tincelles. Supprimer toute source d'ignition. Utiliser un appareillage antidflagrant.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Assurer une bonne ventilation du poste de travail.

Hand Protection

Gants de protection. Temps de rupture (min) : >= 480

Eye Protection

Lunettes de protection.

Respiratory Protection

En cas de ventilation insuffisante, porter un appareil respiratoire approprié

Skin/Body Protection

Vêtements de protection

Environmental Exposure Controls

Éviter le rejet dans l'environnement.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Stable temprature ambiante et dans les conditions normales d'emploi.

Reactivity

Liquide et vapeurs inflammables.

Hazardous Reactions

Formation possible de mlanges vapeur/air inflammables ou explosifs.

Conditions to Avoid

Tempratures leves.

Incompatible Materials

Oxydants puissants. Acides forts. Bases fortes.

Hazardous Decomposition Products

Aucun produit de dcomposition dangereux ne devrait tre gnr dans les conditions normales de stockage et d'emploi.

Section 13

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

Waste Treatment Methods

Eliminer conformment aux prescriptions locales applicables.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN 1263

Proper Shipping Name

PEINTURES (Acétate de n-butyle)

Transport Hazard Class

3

Packing Group

III

ADR Transport Precautions

V12, S2

IMDG Maritime Transport Precautions

Catégorie de chargement: A

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for FIXOLID?

The signal word for this substance is "warning".

What is the physical form of FIXOLID?

FIXOLID is a liquide with variable. color. It has acétate de n-butyle. odor.

What is the solubility of FIXOLID?

Peu soluble dans l'eau.

What is FIXOLID used for?

Peinture

What are the hazard statements for FIXOLID?

This substance has 2 hazard statements: H226: Liquide et vapeurs inflammables. H336: Peut provoquer somnolence ou vertiges.

What is the melting point of FIXOLID?

The melting point is Pas disponible and the boiling point is > 100 °C.