NextSDS Logo
CO

COLLE + ETANCHE POWER NOIR 310ML

NO SIGNAL WORD pte SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
COLLE + ETANCHE POWER NOIR 310ML
Product Code
0893 235 3

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Mastic, Adhsifs Utilisation professionnelle du produit

Overview

COLLE + ETANCHE POWER NOIR 310ML is a pte substance commonly used mastic, adhsifs utilisation professionnelle du produit.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Wrth Belux N.V - S.A.

distributor

📍

Everdongenlaan 29 2300 Turnhout

🌍

BE

📞

+32 (0)14 44 55 66

📠

+32 (0)14 44 55 67

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

+32 (0)70 245 245

🌍

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hydrocarbures, C14-C19, isoalcanes, cycliques, <2% aromatiques 64742-46-7 1-10% ⚠️ Hazardous
Polypropylneglycol 25322-69-4 Not specified ✓ Non-hazardous

Composition Notes

Pour l'explication des abrviations voir rubrique 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

En cas d'inhalation, dplacer l'air frais. Faire appel une assistance mdicale si des symptmes apparaissent.

🖐️ Skin Contact

Laver l'eau et au savon par prcaution. Faire appel une assistance mdicale si des symptmes apparaissent.

👁️ Eye Contact

Rincer les yeux l'eau par mesure de prcaution. Si une irritation se dveloppe et persiste, consulter un mdecin.

Symptoms:

irritation

🍽️ Ingestion/Swallowing

En cas d'ingestion, NE PAS faire vomir. Faire appel une assistance mdicale si des symptmes apparaissent. Rincer soigneusement la bouche avec de l'eau.

🚨 Immediate Medical Attention Required

Faire appel une assistance mdicale si des symptmes apparaissent. Si une irritation se dveloppe et persiste, consulter un mdecin.

Medical Treatment

Effectuer un traitement symptomatique et d'appoint.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
pte
Critical Property
📊 Physical State Data
solid
📊 State Under Standard Conditions
Not available
👁️ Appearance
pte
🎨 Colour
noir
📊 Colour Intensity
Not available
📊 Form
pte
👃 Odor
caractristique
📊 Odor Threshold
Donne non disponible
🧪 Ph
Donne non disponible
🧊 Melting Point
Donne non disponible
Critical Property
💨 Boiling Point
Donne non disponible
Critical Property
🔥 Flash Point
73,5 C
Critical Property
📊 Freezing Point
Donne non disponible
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Donne non disponible
💨 Vapor Pressure
0,01 hPa
📊 Vapor Density
Not available
📊 Relative Density
Not available
📊 Bulk Density
Not available
⚖️ Density
env. 1,49 g/cm (20 C)
Critical Property
🔥 Flammability
Inflammable (voir point d'ignition)
📊 Upper Explosive Limit
Donne non disponible
📊 Lower Explosive Limit
Donne non disponible
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
Donne non disponible
📊 Decomposition Temperature
Donne non disponible
💧 Solubility
insoluble
📊 Partition Coefficient
Non applicable
📊 Solubility In Water
insoluble
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
Not available
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
Not available
📊 Kinematic Viscosity
Donne non disponible
📊 Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Assurer une ventilation adéquate, surtout dans les endroits clos. Réduire au minimum les concentrations d'exposition au travail.

🧤 Hand Protection

Matériel : caoutchouc butyle, épaisseur du gant : 0,4 mm, conforme à la norme EN NBN 374. Matériel : Caoutchouc nitrile, épaisseur du gant : 0,4 mm, conforme à la norme EN NBN 374. Le choix du type de gants de protection contre les produits chimiques doit être effectué en fonction de la concentration et de la quantité des substances dangereuses. Changer souvent de gants!

👁️ Eye Protection

Lunettes de sécurité. Porter des lunettes de protection lorsqu'un risque de contact du produit avec les yeux par inadvertance ne peut être exclu. L'équipement doit être conforme à la norme EN NBN 166.

😷 Respiratory Protection

Utiliser une protection respiratoire si une ventilation locale par aspiration adéquate n'est pas disponible ou si l'évaluation de l'exposition démontre des expositions au-delà des lignes directrices recommandées. L'équipement doit être conforme à la norme EN NBN 133. Filtre de type : Type mixte protégeant des particules et des vapeurs organiques (A-P).

🦺 Skin/Body Protection

Choisir des vêtements de protection appropriés sur base des données de résistance chimique et d'une évaluation du potentiel d'exposition locale. Utiliser un revêtement protecteur antistatique retardateur de flamme si l'évaluation démontre un risque d'atmosphères explosives ou de feux instantanés. Éviter tout contact avec la peau en utilisant des vêtements de protection imperméables (gants, tabliers, bottes, etc.).

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for COLLE + ETANCHE POWER NOIR 310ML?

The signal word for this substance is "no signal word".

What is the physical form of COLLE + ETANCHE POWER NOIR 310ML?

COLLE + ETANCHE POWER NOIR 310ML is a pte appearing as pte with noir color. It has caractristique odor.

What is the solubility of COLLE + ETANCHE POWER NOIR 310ML?

insoluble

What is COLLE + ETANCHE POWER NOIR 310ML used for?

Mastic, Adhsifs Utilisation professionnelle du produit

What is the melting point of COLLE + ETANCHE POWER NOIR 310ML?

The melting point is Donne non disponible and the boiling point is Donne non disponible.