Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Suma Bac D10 commonly used uniquement pour usage professionnel. aise-p314 - dsinfectant de surface. procd manuel aise-p315 - dsinfectant de surface. procd manuel par pulvrisation et rinage.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS05
GHS07
GHS09
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Diversey Europe Operations BV
global supplier
Maarssenbroeksedijk 2, 3542DN Utrecht, The Netherlands
NL
Diversey Belgique
national supplier
Haachtsesteenweg 672, 1910 Kampenhout, Belgique
BE
016-617777
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Centre Antipoisons
070-245245
BE
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mélangeChemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| chlorure d'alkyldiméthylbenzylammonium EC: 270-325-2 | 68424-85-1 | 3-10% | ⚠️ Hazardous |
| alcool éthoxylate d'alkyle EC: Polymer* | 69011-36-5 | 3-10% | ⚠️ Hazardous |
| carbonate de sodium EC: 207-838-8 | 497-19-8 | 1-3% | ⚠️ Hazardous |
Additional Information
[1] exempt: mélange ionique. Voir le Règlement (CE) N1907/2006, Annexe V, paragraphes 3 et 4. Ce sel est potentiellement présent, déterminé par le calcul, et inclus uniquement pour la classification et l'étiquetage. Chaque composant à l'origine du mélange ionique est enregistré, tel que requis. [2] exempt: inclus dans l'annexe IV du Règlement (CE) N1907/2006. [3] exempt: Annexe V du Règlement (CE) N1907/2006. [4] exempt: polymère. Voir l'Article 2(9) du Règlement (CE) N1907/2006.
Composition Notes
Pour le texte intégral des phrases R, H et EUH mentionnés dans cette section, voir section 16. Limite(s) d'exposition au poste de travail, si disponible(s), sont numéres dans le paragraphe 8.1.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
🫁 Inhalation Exposure
Retirer de la source d'exposition. Faire appel une assistance mdicale.
Symptoms:
Provoque des irritations.
🖐️ Skin Contact
Rincer abondamment l'eau. Enlever immdiatement tout vtement souill. Si l'irritation persiste, consulter un mdecin.
Symptoms:
Provoque des irritations.
👁️ Eye Contact
Laver immdiatement et abondamment l'eau. Faire immdiatement appel une assistance mdicale.
Symptoms:
Provoque des irritations svres.
🍽️ Ingestion/Swallowing
Retirer le produit de la bouche. Boire immdiatement un ou deux verres deau ou de lait. Faire appel une assistance mdicale.
Symptoms:
Provoque des irritations.
🚨 Immediate Medical Attention Required
Une assistance médicale est nécessaire en cas d'inhalation, de contact avec les yeux (immédiatement) et d'ingestion. Consulter un médecin si l'irritation cutanée persiste.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
🏭 Engineering Controls
Si le produit est dilu en utilisant des systmes de dosage spcifique sans risque d'claboussures ou de contact cutan direct, l'quipement de protection personnelle tel que dcrits dans cette section n'est pas ncessaire. Pour le produit dilué: Pas d'exigences particulires dans des conditions normales d'utilisation.
🧤 Hand Protection
Gants de protection rsistant aux produits chimiques (EN 374). Vrifiez les instructions concernant la permabilit et le dlai, comme prconis par le fournisseur des gants. Considrer les conditions spcifiques d'utilisation locale, tels que le risque d'claboussures, de coupures, temps de contact et temprature. Gants indiqus pour un contact prolong: Matire: caoutchouc butyle Temps de pntration:> = 480 min Epaisseur du matriau:> = 0,7 mm. Gants indiqus pour la protection contre les claboussures: Matire: caoutchouc nitrile Temps de pntration: >= 30 min Epaisseur du matriau: >= 0.4 mm. En concertation avec le fournisseur de gants de protection, un autre type offrant une protection semblable peut tre choisi. Pour le produit dilué: Rincer et scher les mains aprs utilisation. En cas de contact prolong, une protection de la peau peut tre ncessaire.
👁️ Eye Protection
Lunettes de scurit ou masques protecteurs (EN 166). Pour le produit dilué: Aucune exigence particulire dans les conditions normales d'utilisation.
😷 Respiratory Protection
La protection respiratoire n'est pas normalement requise. Toutefois, l'inhalation des vapeurs, de spray, de gaz ou d'arosols devrait tre vite. Pour le produit dilué: Aucune exigence particulire dans les conditions normales d'utilisation.
🦺 Skin/Body Protection
Aucune exigence particulire dans les conditions normales d'utilisation.
🌍 Environmental Exposure Controls
Ne devrait pas atteindre les gouts ou un foss de drainage sous forme non dilue ou non neutralise. Pour le produit dilué: Pas d'exigences particulires dans des conditions normales d'utilisation.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
🏷️ UN Number
3267
📦 Proper Shipping Name
Corrosive liquid, basic, organic, n.o.s. ( trisodium citrate, alkyldimethylbenzylammoniumchloride )
⚠️ Transport Hazard Class
8
📋 Packing Group
III
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Suma Bac D10?
The signal word for this substance is "no signal word".
What is the physical form of Suma Bac D10?
Suma Bac D10 is a liquide with limpide, pourpre color. It has produit caractristique odor.
What is the solubility of Suma Bac D10?
Compltement miscible
What is Suma Bac D10 used for?
Uniquement pour usage professionnel. AISE-P314 - Dsinfectant de surface. Procd manuel AISE-P315 - Dsinfectant de surface. Procd manuel par pulvrisation et rinage
What is the melting point of Suma Bac D10?
The melting point is Non dtermin and the boiling point is Non dtermin.