NextSDS Logo
Safety Data Sheet FR

GRF EPOXY REPAIR STICK DP 114G*12 L41

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
GRF EPOXY REPAIR STICK DP 114G*12 L41

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Colle

Uses advised against

Pas d'autres informations importantes disponibles.

Manufacturers & Suppliers

U

UHU GmbH & Co.KG

manufacturer

Herrmannstraße 7, D-77815 Bühl (Baden)

0049-(0)7223-284-0

B

Bison International

distributor

Excelsiorlaan 27, B 3, B-1930 Zaventem

+32 3 710 92 92

Emergency Contacts

Centre Antipoisons

070 245245

Luxembourg

8002 - 5500

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
Skin Sens. Cat. 1 H317
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H315 Provoque une irritation cutane.
H317 Peut provoquer une allergie cutane.
H319 Provoque une svre irritation des yeux.
H412 Nocif pour les organismes aquatiques, entrane des effets nfastes long terme.

Precautionary Statements

P101 En cas de consultation d'un mdecin, garder disposition le rcipient ou l'tiquette.
P102 Tenir hors de porte des enfants.
P261 viter de respirer les vapeurs.
P280 Porter des gants de protection.
P302+P352 EN CAS DE CONTACT AVEC LA PEAU: Laver abondamment leau et au savon.
P501 liminer le contenu/rcipient conformment la rglementation nationale.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Colle

Chemical Name CAS Number Concentration Hazardous
produit de réaction: bisphénol-A-épichlorhydrine résines époxydiques (poids moléculaire moyen 700) EC: 500-033-5 25068-38-6 10 - 25% Yes
2,4,6-tris(diméthylaminométhyl)phénol EC: 202-013-9 90-72-2 1 - 2.5% Yes

Pour le libellé des phrases de risque citées, se référer au chapitre 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Donner de l'air frais en abondance et consulter un mdecin pour plus de scurit. En cas d'inconscience, coucher et transporter la personne en position latrale stable.

Skin contact

Laver immdiatement l'eau et au savon et bien rincer.

Eye contact

Rincer les yeux, pendant plusieurs minutes, sous l'eau courante en cartant bien les paupires. Si les troubles persistent, consulter un mdecin.

Ingestion

Si les troubles persistent, consulter un mdecin.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Gants de protection Le matriau des gants doit tre impermable et rsistant au produit / la substance / la prparation. Choix du matriau des gants en fonction des temps de pntration, du taux de permabilit et de la dgradation. Matriau des gants : butyl-rubber (e.g. Butoject 898: material thickness 0,7 mm), Break through time : > 8 h Material : Ethyl Vinyl Alcohol Laminate (EVAL), Break through time : > 8 h glove material for short-term use / splash: (10 min <BTT <480 min): nitrile rubber, neoprene rubber The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough. Take note of the information given by the producer concerning permeability and break through times, and of special workplace conditions (mechanical strain, duration of contact). The suitability for a specific workplace should be discussed with the producers of the protective gloves. Temps de pntration du matriau des gants : Le temps de pntration exact est dterminer par le fabricant des gants de protection et respecter.

Eyes

Lunettes de protection hermtiques Lunettes de protection recommandes pour le transvasement.

Respiratory

N'est pas ncessaire.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Density
Non dtermin.
State Under Standard Conditions
---
Kinematic Viscosity
Non dtermin.
Decomposition Temperature
Non dtermin.
Lower Explosive Limit
Non dtermin.
Dynamic Viscosity
Non dtermin.
Flash Point
>100 C
Physical State Data
liquid
Crystallisation Point
---
Colour Intensity
---
Solubility
---
Freezing Point
Non dtermin.
Evaporation Rate
Non dtermin.
Odor Threshold
Non dtermin.
Boiling Point
Non dtermin.
Molecular Weight
---
Relative Density
Non dtermin.
Cloud Point
---
Colour
Selon dsignation produit
Ph
Non dtermin.
Density
1,9 g/cm
Flammability
Non applicable.
Melting Point
Non dtermin.
Form
Solide
Odor
Caractristique
Auto Ignition Temperature
Le produit ne s'enflamme pas spontanment.
Softening Point
---
Appearance
---
Vapor Pressure
Non dtermin.
Voc Content
---
Physical State
Liquide
Relative Evaporation Rate
---
Solubility In Fat
---
Metal Corrosion
nant
Explosive Limits
---
Bulk Density
---
Properties Status
---
Upper Explosive Limit
Non dtermin.
Partition Coefficient
Non dtermin.
Solubility In Water
Pas ou peu miscible
Solidification Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for GRF EPOXY REPAIR STICK DP 114G*12 L41?

The signal word is warning.

What is the physical form of GRF EPOXY REPAIR STICK DP 114G*12 L41?

GRF EPOXY REPAIR STICK DP 114G*12 L41 is a liquide with selon dsignation produit color. It has caractristique odor.

What is GRF EPOXY REPAIR STICK DP 114G*12 L41 used for?

Colle

What are the hazard statements for GRF EPOXY REPAIR STICK DP 114G*12 L41?

This substance has 4 hazard statements:

  • H315: Provoque une irritation cutane.
  • H317: Peut provoquer une allergie cutane.
  • H319: Provoque une svre irritation des yeux.
  • H412: Nocif pour les organismes aquatiques, entrane des effets nfastes long terme.

What is the melting point of GRF EPOXY REPAIR STICK DP 114G*12 L41?

The melting point is Non dtermin. and the boiling point is Non dtermin..