NextSDS Logo
NU

NUCLISENS EASYMAG - EXTRACTION BUFFER 1

DANGER Liquide. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
NUCLISENS EASYMAG - EXTRACTION BUFFER 1
Product Code
280130

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Dispositif médical de diagnostic in vitro
Uses Advised Against
Aucun connu.

Overview

NUCLISENS EASYMAG - EXTRACTION BUFFER 1 commonly used dispositif médical de diagnostic in vitro.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Acute Tox. Category 4
Acute Tox. Category 4
Acute Tox. Category 4
Skin Corr. Category 1C
Aquatic Chronic Category 3

GHS Hazard Pictograms & Safety Symbols

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H302 + H312 + H332: Nocif en cas d'ingestion, de contact cutan ou d'inhalation.
  • H314: Provoque de graves brlures de la peau et de graves lsions des yeux.
  • H412: Nocif pour les organismes aquatiques, entrane des effets nfastes long terme.

Precautionary Statements

  • P260: Ne pas respirer les poussires ou les brouillards.
  • P261: viter de respirer les vapeurs.
  • P264: Se laver soigneusement aprs manipulation.
  • P270: Ne pas manger, boire ou fumer en manipulant ce produit.
  • P273: viter le rejet dans lenvironnement.
  • P280: Porter des gants de protection/des vtements de protection/un quipement de protection des yeux/du visage.
  • P301 + P330 + P331: EN CAS D'INGESTION: Rincer la bouche. NE PAS faire vomir.
  • P302 + P352: EN CAS DE CONTACT AVEC LA PEAU: Laver abondamment leau.
  • P305 + P351 + P338: EN CAS DE CONTACT AVEC LES YEUX: Rincer avec prcaution l'eau pendant plusieurs minutes. Enlever les lentilles de contact si la victime en porte et si elles peuvent tre facilement enleves. Continuer rincer.
  • P310: Appeler immdiatement un CENTRE ANTIPOISON ou un mdecin.
  • P330: Rincer la bouche.
  • P362 + P364: Enlever les vtements contamins et les laver avant rutilisation.
  • P501: liminer le contenu/rcipient conformment aux rglementations locales/rgionales/nationales/internationales.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

bioMérieux SA

national supplier

📍

Chemin de l'Orme - 69280 Marcy-l'Etoile - France

🌍

FR

📞

+33 (0)4 78 87 23 30

📠

+33(0)478872080

bioMérieux SA

manufacturer

📍

Chemin de l'Orme - 69280 Marcy-l'Etoile - France

🌍

FR

📞

+33 (0)4 78 87 23 30

📠

+33(0)478872080

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

INRS

📞

+33(0)1 45 42 59 29

🌍

FR

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Toutes les concentrations sont donnes en pourcentage massique sauf pour les ingrdients sous forme gazeuse. Les concentrations des gaz sont exprimes en pourcentage volumique.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Guanidine Thiocyanate
EC: 209-812-1
593-84-0 50-60% ⚠️ Hazardous
Polymeer uit ethyleenglycol en (1,1,3,3-Tetramethylbutyl)-fe nol
EC: 618-541-1
9036-19-5 1-3% ⚠️ Hazardous
Autres composants sous les niveaux dclarables N/A 40-50% ✓ Non-hazardous

Composition Notes

Le texte intgral de toutes les phrases R et mentions H est prsent en section 16. Le texte intgral de toutes les mentions H est prsent en section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Consulter immdiatement un mdecin. Transporter la victime l'extrieur et la maintenir au repos dans une position o elle peut confortablement respirer. Oxygne ou respiration artificielle si ncessaire. Ne pas utiliser le bouche--bouche si la victime a inhal la substance. Contacter un mdecin si les symptmes se dveloppent ou persistent.

🖐️ Skin Contact

Enlever immdiatement tous les vtements contamins. Rincer immdiatement la peau grande eau. Lors d'un contact cutan mineur, viter d'taler la substance sur la peau non contamine. Consulter un mdecin si une irritation se dveloppe et persiste.

👁️ Eye Contact

Laver immdiatement les yeux grande eau pendant au moins 15 minutes. Les personnes portant des lentilles de contact doivent autant que possible les enlever. Rincer continuellement. Contacter immdiatement un mdecin ou un centre antipoison.

🍽️ Ingestion/Swallowing

Rincer la bouche. En cas de vomissement, garder la tte basse pour viter une pntration du contenu de l'estomac dans les poumons. Ne pas utiliser le bouche--bouche si la victime a ingr la substance.

🚨 Immediate Medical Attention Required

Consulter immdiatement un mdecin. Contacter immdiatement un mdecin ou un centre antipoison.

Medical Treatment

En cas de difficults respiratoires, donner de l'oxygne.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧊 Melting Point
Non disponible.
Critical Property
📊 Dynamic Viscosity
Not available
📊 Upper Explosive Limit
Non disponible.
📊 Solubility In Water
Non disponible.
🎨 Colour
Incolore ou presque incolore
📊 Voc Content
Not available
📊 Decomposition Temperature
Non disponible.
💧 Solubility
Non disponible.
📊 Relative Evaporation Rate
Not available
📊 State Under Standard Conditions
Not available
📊 Kinematic Viscosity
Non disponible.
📊 Metal Corrosion
Not available
📊 Molecular Weight
Not available
📊 Softening Point
Not available
📊 Relative Density
Non disponible.
💨 Evaporation Rate
Not available
💨 Boiling Point
Non disponible.
Critical Property
📊 Cloud Point
Not available
📊 Odor Threshold
Not available
📊 Solidification Point
Not available
📊 Physical State Data
liquid
📊 Explosive Limits
Not available
👁️ Appearance
Not available
📊 Crystallisation Point
Not available
📊 Auto Ignition Temperature
Non disponible.
📊 Lower Explosive Limit
Non disponible.
📊 Properties Status
Not available
📊 Solubility In Fat
Not available
🧪 Ph
7
📊 Freezing Point
Non disponible.
📊 Vapor Density
Non disponible.
💨 Vapor Pressure
Non disponible.
⚖️ Density
Non disponible.
Critical Property
🧪 Physical State
Liquide.
Critical Property
🔥 Flammability
Non applicable.
📊 Bulk Density
Not available
📊 Form
Not available
🔥 Flash Point
Non disponible.
Critical Property
📊 Colour Intensity
Not available
👃 Odor
Non disponible.
📊 Partition Coefficient
Non disponible.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Assurer une bonne ventilation gnrale (gnralement 10 renouvellements d'air l'heure). Le taux de renouvellement d'air devrait tre adapt aux conditions. Si c'est appropri, cltures de processus d'utilisation, ventilation d'chappement locale, ou d'autres commandes de technologie pour maintenir les niveaux aroports au-dessous des limites recommandes d'exposition. Si des limites d'exposition n'ont pas t tablies, maintenez les niveaux aroports un niveau acceptable. Des dispositifs de rinage oculaire et des douches d'urgence doivent tre disponibles sur le lieu de travail pendant la manipulation de ce produit.

🧤 Hand Protection

Porter des gants de protection. Utiliser des gants de protection en : Nitrile.

👁️ Eye Protection

Le port d'un masque facial est conseill. Perter des lunettes de scurit crans latraux.

😷 Respiratory Protection

Une protection respiratoire n'est pas requise.

🦺 Skin/Body Protection

Porter un vtement de protection appropri. Porter des gants de protection.

🌍 Environmental Exposure Controls

Informer les cadres ou superviseurs concerns de tout rejet dans lenvironnement.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN1760

📦 Proper Shipping Name

Liquide corrosif, n.s.a (Thiocyanate de guanidinium)

⚠️ Transport Hazard Class

8

📋 Packing Group

III

🚛 ADR Transport Precautions

Consulter les instructions de scurit, la FDS et les procdures d'urgence avant toute manipulation.

🚢 IMDG Maritime Transport Precautions

Consulter les instructions de scurit, la FDS et les procdures d'urgence avant toute manipulation.

✈️ IATA Air Transport Precautions

Consulter les instructions de scurit, la FDS et les procdures d'urgence avant toute manipulation.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for NUCLISENS EASYMAG - EXTRACTION BUFFER 1?

The signal word for this substance is "danger".

What is the physical form of NUCLISENS EASYMAG - EXTRACTION BUFFER 1?

NUCLISENS EASYMAG - EXTRACTION BUFFER 1 is a liquide. with incolore ou presque incolore color. It has non disponible. odor.

What is the solubility of NUCLISENS EASYMAG - EXTRACTION BUFFER 1?

Non disponible.

What is NUCLISENS EASYMAG - EXTRACTION BUFFER 1 used for?

Dispositif médical de diagnostic in vitro

What are the hazard statements for NUCLISENS EASYMAG - EXTRACTION BUFFER 1?

This substance has 3 hazard statements: H302 + H312 + H332: Nocif en cas d'ingestion, de contact cutan ou d'inhalation. H314: Provoque de graves brlures de la peau et de graves lsions des yeux. H412: Nocif pour les organismes aquatiques, entrane des effets nfastes long terme.

What is the melting point of NUCLISENS EASYMAG - EXTRACTION BUFFER 1?

The melting point is Non disponible. and the boiling point is Non disponible..