NextSDS Logo
Hy

Hydrofix Gel

NO SIGNAL WORD Liquide SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Hydrofix Gel
Product Form
Mlange

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Gel fixant incolore pour murs intrieurs et extrieurs secs.
Uses Advised Against
Pas d'informations complmentaires disponibles

Overview

Hydrofix Gel commonly used gel fixant incolore pour murs intrieurs et extrieurs secs..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • P102: Tenir hors de porte des enfants.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Boss paints N.V. company logo - Safety Data Sheet supplier organization

Boss paints N.V.

distributor

πŸ“

Nijverheidstraat 81 BE 8791 Waregem West-Vlaanderen Belgi

🌍

BE

πŸ“ž

+32 56 738 200

πŸ“ 

+32 56 738 201

🌐 www.boss.be

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Amener le sujet l'air frais. En cas d'arrt respiratoire, pratiquer la respiration artificielle. Ne pas ingrer.

Symptoms:

Pas d'effets observs.

πŸ–οΈ Skin Contact

Oter les vtements touchs et laver les parties exposes de la peau au moyen d'un savon doux et d'eau, puis rincer l'eau chaude. Eviter d'utiliser un solvant.

Symptoms:

Pas d'effets observs.

πŸ‘οΈ Eye Contact

Enlever les lentilles de contact si la victime en porte et si elles peuvent tre facilement enleves. Continuer rincer. Consulter immdiatement un mdecin.

Symptoms:

Pas d'effets observs.

🍽️ Ingestion/Swallowing

Consulter d'urgence un mdecin. Mettre la victime au repos. NE PAS faire vomir.

Symptoms:

Pas d'effets observs.

🚨 Immediate Medical Attention Required

Consulter d'urgence un mdecin. Un traitement spcifique immdiat est ncessaire en cas d'intoxication.

Medical Treatment

Traitement symptomatique. Un traitement spcifique immdiat est ncessaire en cas d'intoxication.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ§ͺ Physical State
Liquide
Critical Property
πŸ“Š Physical State Data
liquid
πŸ“Š State Under Standard Conditions
Not available
πŸ‘οΈ Appearance
Not available
🎨 Colour
laiteux.
πŸ“Š Colour Intensity
Not available
πŸ“Š Form
Not available
πŸ‘ƒ Odor
inodore.
πŸ“Š Odor Threshold
Pas disponible
πŸ§ͺ Ph
8
🧊 Melting Point
< 0 C
Critical Property
πŸ’¨ Boiling Point
- 100 C
Critical Property
πŸ”₯ Flash Point
Non applicable
Critical Property
πŸ“Š Freezing Point
Pas disponible
πŸ“Š Softening Point
Not available
πŸ“Š Solidification Point
Not available
πŸ“Š Cloud Point
Not available
πŸ“Š Crystallisation Point
Not available
πŸ“Š Relative Evaporation Rate
Not available
πŸ’¨ Evaporation Rate
Not available
πŸ’¨ Vapor Pressure
< 2,3 kPa
πŸ“Š Vapor Density
Not available
πŸ“Š Relative Density
Pas disponible
πŸ“Š Bulk Density
Not available
βš–οΈ Density
1,02 g/cm
Critical Property
πŸ”₯ Flammability
Ininflammable.
πŸ“Š Upper Explosive Limit
Non applicable
πŸ“Š Lower Explosive Limit
Non applicable
πŸ“Š Explosive Limits
Not available
πŸ“Š Auto Ignition Temperature
Non applicable
πŸ“Š Decomposition Temperature
Non applicable
πŸ’§ Solubility
Miscible avec l'eau.
πŸ“Š Partition Coefficient
Non applicable
πŸ“Š Solubility In Water
Not available
πŸ“Š Solubility In Fat
Not available
πŸ“Š Molecular Weight
Not available
πŸ“Š Voc Content
Not available
πŸ“Š Metal Corrosion
Not available
πŸ“Š Dynamic Viscosity
Not available
πŸ“Š Kinematic Viscosity
- 20,5 mm/s
πŸ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Assurer une bonne ventilation du poste de travail. Aspiration locale ou protection respiratoire. En cas de ventilation insuffisante, porter un appareil respiratoire appropri.

🧀 Hand Protection

des gants de protection. Type: Gants rutilisables, MatΓ©riau: Caoutchouc butyle, PermΓ©ation: 4 (> 120 minutes), Epaisseur: 0.5 mm, Norme: EN ISO 374.

πŸ‘οΈ Eye Protection

Lunettes de protection. Type: Lunettes de sΓ©curitΓ©, Champ d'application: Gouttelettes avec protections latΓ©rales, Norme: EN 166.

😷 Respiratory Protection

Si le mode d'utilisation du produit entrane un risque d'exposition par inhalation, porter un quipement de protection respiratoire. Appareil: Demi-masque rutilisable, Type de filtre: A2P2, Condition: Si conc. dans l'air > limite d'exposition, Pulvrisation en dehors d'installations industrielles.

🦺 Skin/Body Protection

Porter un vtement de protection appropri

🌍 Environmental Exposure Controls

viter le rejet dans l'environnement.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Hydrofix Gel?

The signal word for this substance is "no signal word".

What is the physical form of Hydrofix Gel?

Hydrofix Gel is a liquide with laiteux. color. It has inodore. odor.

What is the solubility of Hydrofix Gel?

Miscible avec l'eau.

What is Hydrofix Gel used for?

Gel fixant incolore pour murs intrieurs et extrieurs secs.

What is the melting point of Hydrofix Gel?

The melting point is < 0 C and the boiling point is - 100 C.