NextSDS Logo
Safety Data Sheet FR

NAFTOLUBE OPA II

CAS 68441-17-8
EC 614-498-8

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
NAFTOLUBE OPA II

Regulatory Identifiers

CAS Number
68441-17-8 Check regulations →
EC Number
614-498-8 Check regulations →
REACH No.
17-2119946285-32-

Identified Uses

Lubrifiant

Manufacturers & Suppliers

C

CHEMSON POLYMER-ADDITIVE AG

manufacturer

Industriestraße 19, A-9601 ARNOLDSTEIN

0043 4255 2226 0

Emergency Contacts

Centre Anti-Poisons/Antigifcentrum

+32 70 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Ethene, homopolymer, oxidized EC: 614-498-8 68441-17-8 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Apport d'air frais, consulter un médecin en cas de troubles.

Skin contact

Enlever les vêtements contaminés. Bien laver les parties de la peau concernées à l'eau et au savon.

Eye contact

Lavage avec de l'eau en écartant les paupières plusieurs minutes. Si les troubles persistent, consulter un médecin.

Ingestion

Rincer la bouche à l'eau. Si les troubles persistent, consulter un médecin. Lui montrer cette Fiche de données de sécurité.

Medical Treatment

Pas d'autres informations importantes disponibles.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, poudre d'extinction ou eau pulvérisée. Lutter contre les incendies importants avec de l'eau pulvérisée ou de la mousse résistant à l'alcool.

Specific hazards

Pas d'autres informations importantes disponibles.

Firefighter Protection

Aucune mesure particulière n'est requise.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Ne pas rejeter dans le milieu naturel.

Cleanup methods

Recueillir par moyen mécanique.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Veiller à une bonne ventilation/aspiration du poste de travail.

Storage

Stocker dans un endroit frais. Placer dans un endroit sec.

Fire prevention

Tenir à l'abri de sources d'inflammation - ne pas fumer.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Sans autre indication, voir point 7.

Hands

Gants de protection. Matériau des gants: Gants en cuir

Eyes

Lunettes de protection.

Respiratory

Filtre P1.

Skin/Body

Vêtements de travail protecteurs.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Upper Explosive Limit
non déterminé
Crystallisation Point
---
Decomposition Temperature
non déterminé
Appearance
poudre
Lower Explosive Limit
non déterminé
Flammability
Non applicable.
Metal Corrosion
---
Solubility In Fat
---
Vapor Pressure
Non déterminé.
Softening Point
---
Molecular Weight
---
Odor
caractéristique
Odor Threshold
Non déterminé.
Freezing Point
---
Physical State Data
solid
Bulk Density
---
Solidification Point
---
Solubility In Water
Non déterminé.
Ph
Non déterminé.
Density
0,96 g/cm³
Evaporation Rate
Non applicable.
Colour
blanchâtre
Colour Intensity
---
Relative Density
Non déterminé.
Partition Coefficient
Non déterminé.
Flash Point
> 255 °C
Voc Content
---
Relative Evaporation Rate
---
Physical State
poudre
Kinematic Viscosity
Non déterminé.
Vapor Density
Non déterminé.
Cloud Point
---
Melting Point
non déterminé
Auto Ignition Temperature
néant
Boiling Point
non déterminé
Explosive Limits
---
Properties Status
---
Solubility
Non déterminé.
Dynamic Viscosity
Non déterminé.
Form
poudre
State Under Standard Conditions
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Pas de décomposition en cas d'usage conforme.

Reactivity

Pas d'autres informations importantes disponibles.

Hazardous reactions

Réactions aux agents d'oxydation puissants

Avoid

Pas d'autres informations importantes disponibles.

Incompatible

Pas d'autres informations importantes disponibles.

Decomposition

Monoxyde de carbone et dioxyde de carbone

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Pour le recyclage, s'adresser au producteur. De petites quantités peuvent être mises en décharge avec les ordures ménagères.

Disposal

Pour le recyclage, s'adresser au producteur. De petites quantités peuvent être mises en décharge avec les ordures ménagères.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
néant
Shipping Name
néant
Transport Class
néant
Packing Group
néant
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for NAFTOLUBE OPA II?

The signal word is no signal word.

What is the physical form of NAFTOLUBE OPA II?

NAFTOLUBE OPA II is a poudre appearing as poudre with blanchâtre color. It has caractéristique odor.

What is the solubility of NAFTOLUBE OPA II?

Non déterminé.

What is NAFTOLUBE OPA II used for?

Lubrifiant

What is the melting point of NAFTOLUBE OPA II?

The melting point is non déterminé and the boiling point is non déterminé.

Compliance Scanner

Scan your compliance