NextSDS Logo
Safety Data Sheet FR

JOHNSONDIVERSEY JONTEC FUTUR JFILL F1d

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
JOHNSONDIVERSEY JONTEC FUTUR JFILL F1d

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Produit professionnel de nettoyage / de maintenance pour l'entretien des bâtiments.

Manufacturers & Suppliers

J

JohnsonDiversey Belgium

manufacturer

Haachtsesteenweg 672, 1910 Kampenhout, Belgique

016-617777

Emergency Contacts

JohnsonDiversey Belgium

016-617777

Centre Antipoisons

070-245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

C Corrosif

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mélange aqueux composé de substances mentionnées ci-dessous et d'additifs inoffensifs.

Chemical Name CAS Number Concentration Hazardous
2-aminoéthanol EC: 205-483-3 141-43-5 30% Yes
alcool benzylique EC: 202-859-9 100-51-6 15 - 30% Yes
2-hexyloxyéthanol EC: 203-951-1 112-25-4 15 - 30% Yes
alkyl alcohol ethoxylate 84133-50-6 5% Yes
savon --- 5 - 15% No
agents de surface non ioniques --- 5% No
Benzyl Alcohol --- --- No

Indications complémentaires: Pour le libellé des phrases de risque citées, se référer au chapitre 16.

Notes

Substances dangereuses:

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Donner de l'air frais. Assistance respiratoire si nécessaire. Tenir le malade au chaud. Si les troubles persistent, consulter un médecin. En cas d'inconscience, coucher et transporter la personne en position latérale stable.

Skin contact

Laver immédiatement à l'eau et au savon et bien rincer.

Eye contact

Rinçage à l'eau en écartant les paupières plusieurs minutes et consulter un médecin.

Ingestion

Faire boire de l'eau en abondance et donner de l'air frais. Consulter immédiatement un médecin.

Immediate Medical Attention

Consulter immédiatement un médecin en cas d'ingestion. Si les troubles persistent après inhalation ou contact cutané, consulter un médecin.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, poudre d'extinction ou eau pulvérisée. Combattre les foyers importants par de l'eau pulvérisée ou de la mousse résistante à l'alcool.

Firefighter Protection

Porter un appareil de protection respiratoire.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Porter un équipement de sécurité. Eloigner les personnes non protégées.

Environmental

Diluer avec beaucoup d'eau.

Cleanup methods

Recueillir les liquides à l'aide d'un produit absorbant

Materials: sable, kieselguhr, liant universel, sciure

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Veiller à une bonne ventilation/aspiration du poste de travail.

Storage

Tenir les emballages hermétiquement fermés. Selon la législation locale en vigueur.

Fire prevention

Aucune mesure particulière n'est requise.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Sans autre indication, voir point 7.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquide
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
transparent, jaune
Colour
transparent, jaune
Colour Intensity
---
Form
liquide
Odor
caractéristique
Odor Threshold
---
Ph
pH > 12.5
Melting Point
non-déterminé
Boiling Point
non déterminé
Flash Point
non-applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0,98 g/cm³
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
Le produit ne s'enflamme pas spontanément.
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
entièrement miscible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

Réactions aux acides

Avoid

Pas de décomposition en cas d'usage conforme

Incompatible

acides

Decomposition

Pas de produits de decomposition dangereux connus

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3267
Shipping Name
LIQUIDE ORGANIQUE CORROSIF, BASIQUE, N.S.A. (ETHANOLAMINE, 2-hexyloxyéthanol)
Transport Class
8
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for JOHNSONDIVERSEY JONTEC FUTUR JFILL F1d?

The signal word is na: r-phrases.

What is the physical form of JOHNSONDIVERSEY JONTEC FUTUR JFILL F1d?

JOHNSONDIVERSEY JONTEC FUTUR JFILL F1d is a liquide appearing as transparent, jaune with transparent, jaune color. It has caractéristique odor.

What is JOHNSONDIVERSEY JONTEC FUTUR JFILL F1d used for?

Produit professionnel de nettoyage / de maintenance pour l'entretien des bâtiments.

What is the melting point of JOHNSONDIVERSEY JONTEC FUTUR JFILL F1d?

The melting point is non-déterminé and the boiling point is non déterminé.