NextSDS Logo
Safety Data Sheet FR

THERM

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
THERM
Product Form
liquide

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Déboucheur industriel liquide

Manufacturers & Suppliers

A

ALPHA INDUSTRIES (Prodal bvba)

distributor

Melkerijweg 2, 2240 Zandhoven

+32.3.665.01.59

Emergency Contacts

Tél Urgences Belgique

070.245.245

Tél Urgences mondiale

XX32.70.245.245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Provoque de graves brûlures
Risque de lésions oculaires graves

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H314 Provoque de graves brûlures
H318 Risque de lésions oculaires graves

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Chemical Name CAS Number Concentration Hazardous
Acide sulfurique EC: 231-639-5 7664-93-9 50 - 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

air frais, repos

Skin contact

retirer les vêtements souillés, rincer la peau avec beaucoup d'eau et transporter immédiatement à l'hôpital

Eye contact

rincer d'abord avec beaucoup d'eau, ensuite transporter chez le médecin

Ingestion

rincer la bouche et transporter immédiatement à l'hôpital

Immediate Medical Attention

transporter immédiatement à l'hôpital en cas de contact avec la peau ou ingestion

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

ininflammable

Unsuitable media

aucun

Instructions

aucun

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

au cas où le produit non dilué serait évacué accidentellement, le neutraliser jusqu'au pH 7

Environmental

ne pas déverser dans les égouts ou dans les eaux publiques

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

traiter avec prudence afin d'éviter des fuites

Storage

conserver dans un emballage bien fermé dans un endroit fermé, à l'abri du gel et bien ventilé

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

gants, chimiquement résistante

Eyes

lunettes

Respiratory

aucun

Skin/Body

vêtements appropriés

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquide
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
---
Colour Intensity
---
Form
---
Odor
inodore
Odor Threshold
---
Ph
0,1
Melting Point
-20 °C
Boiling Point
290 °C
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
1,830
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
complètement soluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
1 mPa.s
Kinematic Viscosity
1 mm²/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

produits organiques, base

Avoid

éviter des fuites

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1830
Shipping Name
Acide sulfurique
Transport Class
8
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for THERM?

The signal word is danger.

What is the physical form of THERM?

THERM is a liquide . It has inodore odor.

What is THERM used for?

Déboucheur industriel liquide

What are the hazard statements for THERM?

This substance has 2 hazard statements:

  • H314: Provoque de graves brûlures
  • H318: Risque de lésions oculaires graves

What is the melting point of THERM?

The melting point is -20 °C and the boiling point is 290 °C.