NextSDS Logo
Safety Data Sheet FR

FloorPro Nettoyant industriel RM 69

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
FloorPro Nettoyant industriel RM 69

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Produit de nettoyage

Uses advised against

Pas d'autres informations importantes disponibles.

Manufacturers & Suppliers

A

Alfred Kärcher SE & Co. KG

manufacturer

Alfred-Kärcher-Str. 28-40, D - 71364 Winnenden

+49-7195-14-0

K

Kärcher N.V.

national supplier

Boomsesteenweg 939, BE - 2610 Wilrijk (Antwerpen)

+32-3-3400-711

D

Département TCD-D

manufacturer

+49-7195-14-2548

Emergency Contacts

CHEMTREC

1-800-424-9300

24h/24

CHEMTREC

+1 703-741-5970

24h/24

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mélange effectué à partir des matériaux mentionnés ci - après et avec des additifs non dangereux

Chemical Name CAS Number Concentration Hazardous
2-(2-butoxyéthoxy)éthanol EC: 203-961-6 112-34-5 1 - 5% Yes
agents de surface non ioniques --- 5% No
parfums --- --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Donner de l'air frais, consulter un médecin en cas de troubles.

Skin contact

En règle générale, le produit n'irrite pas la peau.

Eye contact

Lavage avec de l'eau en écartant les paupières plusieurs minutes.

Ingestion

Rincer la bouche et boire ensuite abondamment. Si les troubles persistent, consulter un médecin.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, poudre d'extinction ou eau pulvérisée. Combattre les foyers importants par de l'eau pulvérisée ou de la mousse résistant à l'alcool.

Unsuitable media

Jet d'eau à grand débit.

Specific hazards

Pas d'autres informations importantes disponibles.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Non nécessaire

Environmental

Ne pas rejeter à l'égout, ni dans le milieu naturel. Diluer avec beaucoup d'eau.

Cleanup methods

Recueillir les liquides à l'aide d'un produit absorbant

Materials: sable, kieselguhr, neutralisant d'acide, liant universel

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Aucune mesure particulière n'est requise.

Storage

Aucune exigence particulière.

Fire prevention

Aucune mesure particulière n'est requise.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Non nécessaire. Le choix de gants appropriés dépend non seulement du matériau, mais aussi d'autres critères de qualité qui peuvent varier d'un fabricant à l'autre. Puisque le produit représente une préparation composée de plusieurs substances, la résistance des matériaux des gants ne peut pas être calculée à l'avance et doit, alors, être contrôlée avant l'utilisation. Le temps de pénétration exact est à déterminer par le fabricant des gants de protection et à respecter.

Eyes

Lunettes de protection recommandées pour le transvasement.

Respiratory

Ne pas nécessaire si la pièce dispose d'une bonne ventilation.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
liquide
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
bleu, frais
Colour
bleu
Colour Intensity
---
Form
liquide
Odor
frais
Odor Threshold
Non déterminé.
Ph
10,7
Melting Point
0 °C
Boiling Point
100 °C
Flash Point
non applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Non déterminé.
Vapor Pressure
Non déterminé.
Vapor Density
Non déterminé.
Relative Density
Non déterminé.
Bulk Density
---
Density
1,007 g/cm³
Flammability
Non applicable.
Upper Explosive Limit
Non déterminé.
Lower Explosive Limit
Non déterminé.
Explosive Limits
---
Auto Ignition Temperature
Le produit ne s'enflamme pas spontanément.
Decomposition Temperature
Non déterminé.
Solubility
---
Partition Coefficient
Non déterminé.
Solubility In Water
entièrement miscible
Solubility In Fat
---
Molecular Weight
---
Voc Content
4,8 %
Metal Corrosion
---
Dynamic Viscosity
Non déterminé.
Kinematic Viscosity
Non déterminé.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Pas de décomposition en cas d'usage conforme.

Reactivity

10.1 Réactivité correspond à 10.3

Hazardous reactions

Aucune réaction dangereuse connue.

Avoid

Pas de décomposition en cas d'usage conforme.

Incompatible

Pas d'autres informations importantes disponibles.

Decomposition

Pas de produits de décomposition dangereux connus

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicité

Toxicité aquatique : 112-34-5 2-(2-butoxyéthoxy)éthanol LC50/96 h 1.300 mg/l (Lepomis macrochirus) EC10/16 h 1.170 mg/l (Pseudomonas putida) EC50/24 h 2.850 mg/l (Daphnia magna) (DIN 38412) NOEC >100 mg/l (Desmodesmus subspicatus)

12.2 Persistence et dégradabilité

Pas d'autres informations importantes disponibles. Le(s) agent(s) de surface contenu(s) dans cette préparation respecte(nt) les critères de biodégradabilité comme définis dans la réglementation (CE) no 648/2004 relatif aux détergents. Les données prouvant cette affirmation sont tenues à la disposition des autorités compétentes des Etats Membres et leur seront fournies à leur demande expresse ou à la demande du producteur de détergents. Les formateurs de complexes organiques contenus atteignent un taux d'élimination DOC de 80% (correspondant au N°406 de l'annexe "Méthodes d'analyses et de mesures") et répondent, ainsi, aux exigences plus sévères de l'annexe 49 de la nouvelle directive pour les eaux résiduaires.

12.3 Potentiel de bioaccumulation

Pas d'autres informations importantes disponibles.

12.4 Mobilité dans le sol

Pas d'autres informations importantes disponibles.

12.5 Résultats des évaluations PBT et VPVB

- PBT: Non applicable. vPvB: Non applicable.

La substance n'est pas considérée comme PBT ou vPvB.

12.6 Autres effets néfastes

Pas d'autres informations importantes disponibles.

Pas d'autres informations importantes disponibles.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Remettre à la collecte de déchets toxiques ou apporter à la déchetterie pour déchets dangereux. De petites quantités peuvent être diluées avec beaucoup d'eau et éliminées. De plus grandes quantités sont à éliminer conformément aux normes des autorités locales.

Disposal

Remettre à la collecte de déchets toxiques ou apporter à la déchetterie pour déchets dangereux.

Waste Codes

20 01 30 détergents autres que ceux visés à la rubrique 20 01 29 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for FloorPro Nettoyant industriel RM 69?

The signal word is no signal word.

What is the physical form of FloorPro Nettoyant industriel RM 69?

FloorPro Nettoyant industriel RM 69 is a liquide appearing as bleu, frais with bleu color. It has frais odor.

What is FloorPro Nettoyant industriel RM 69 used for?

Produit de nettoyage

What is the melting point of FloorPro Nettoyant industriel RM 69?

The melting point is 0 °C and the boiling point is 100 °C.