NextSDS Logo
Safety Data Sheet FR

Stokosept® gel

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Stokosept® gel
Product Form
Gel

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Gel pour l'hygiène par les mains saines

Manufacturers & Suppliers

E

Evonik Industries AG

manufacturer

Bäkerpfad 25, 47805 Krefeld, Allemagne

+49-2151-38-1370

Emergency Contacts

Centre Antipoisons, Belgique

070/245.245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H225 Liquide et vapeurs très inflammables.

Precautionary Statements

P101 En cas de consultation d'un médecin, garder à disposition le récipient ou l'étiquette.
P102 À conserver hors de portée des enfants.
P210 Tenir à l'écart de la chaleur/des étincelles/des flammes nues/des surfaces chaudes. - Ne pas fumer.
P233 Maintenir le récipient fermé de manière étanche.
P301 EN CAS D'INGESTION:
P305 EN CAS DE CONTACT AVEC LES YEUX:
P313 Consulter un médecin.
P315 Consulter immédiatement un médecin.
P351 Rincer avec précaution à l'eau pendant plusieurs minutes.
P403 Stocker dans un endroit bien ventilé.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
éthanol EC: 200-578-6 64-17-5 58 - 62% Yes
propane-2-ol; alcool isopropylique EC: 200-661-7 67-63-0 10% Yes
(2-hydroxy-4-méthoxyphényl)phényl-méthanone EC: 205-031-5 131-57-7 0.2% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Assurer une ventilation suffisante.

Symptoms: Mal de tête, engourdissement

Skin contact

ne s'applique pas

Eye contact

Rincer longuement avec beaucoup d'eau et consulter un médecin.

Ingestion

En cas d'ingestion consulter immédiatement un médecin et lui montrer l'emballage ou l'étiquette.

Medical Treatment

Traiter de façon symptomatique.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

jet d'eau, dioxyde de carbone, mousse, extincteur à sec., La mousse doit être résistante aux solvants polaires.

Specific hazards

Des vapeurs peuvent former un mélange explosif avec l'air.

Instructions

comme pour les liquides inflammables

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Tenir à l'écart de sources d'inflammation. Prevoir une ventilation suffisante. L'éclaboussement de ce produit rend toute surface glissante.

Environmental

Absorber et jeter.

Cleanup methods

Absorber avec des agents inertes, non inflammables

Materials: liant universel ou Kieselguhr

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Conserver le récipient bien fermé. Eviter tout contact avec les yeux

Storage

Conserver le récipient bien fermé.

Fire prevention

Conserver à l'écart de toute source d'ignition. Refroidir les réservoirs menacés.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

non indispensable

Eyes

non indispensable dans les conditions normales d'utilisation

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solidification Point
---
Partition Coefficient
---
Flash Point
10 °C (DIN 51 755)
Lower Explosive Limit
2,00 % (v) (2-propanol), 3,5 % (v) (éthanol)
Vapor Density
---
Kinematic Viscosity
---
Physical State
gel
Solubility In Fat
---
Voc Content
---
Odor Threshold
---
Physical State Data
liquid
Melting Point
<20 °C
Flammability
---
Bulk Density
---
Relative Density
---
Cloud Point
---
Form
gel
Crystallisation Point
---
Colour Intensity
---
Odor
d'alcool
Molecular Weight
---
Relative Evaporation Rate
---
Appearance
---
Explosive Limits
---
Ph
environ 6,5 (100 g/l) (20 °C)
State Under Standard Conditions
---
Dynamic Viscosity
environ 7.500 mPa.s (20 °C)
Metal Corrosion
---
Solubility
---
Density
environ 0,875 g/cm3 (20 °C)
Boiling Point
80 - 90 °C
Softening Point
---
Evaporation Rate
---
Auto Ignition Temperature
non déterminée
Solubility In Water
(20 °C) soluble
Vapor Pressure
environ 300 hPa (55 °C)
Decomposition Temperature
---
Freezing Point
---
Properties Status
---
Upper Explosive Limit
15,00 % (v) (éthanol), 12,00 % (v) (2-propanol)
Colour
incolore
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

stable dans les conditions habituelles d'utilisation.

Reactivity

voir section 10.2.

Hazardous reactions

La formation de mélanges inflammables avec l'air est possible pendant le chauffage ou la vaporisation. Tenir éloigné de la chaleur et des dispositifs d'allumage.

Avoid

Conserver à l'écart de toute source d'ignition.

Incompatible

oxydants

Decomposition

Le chauffage peut dégager des vapeurs qui peuvent s'enflammer.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1987
Shipping Name
ALCOOLS, N.S.A. (contient éthanol et isopropanol, mélange)
Transport Class
3
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Stokosept® gel?

The signal word is danger.

What is the physical form of Stokosept® gel?

Stokosept® gel is a gel with incolore color. It has d'alcool odor.

What is Stokosept® gel used for?

Gel pour l'hygiène par les mains saines

What are the hazard statements for Stokosept® gel?

This substance has 1 hazard statement:

  • H225: Liquide et vapeurs très inflammables.

What is the melting point of Stokosept® gel?

The melting point is <20 °C and the boiling point is 80 - 90 °C.