NextSDS Logo
Safety Data Sheet FR

R-Clean Relavit Forte

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
R-Clean Relavit Forte

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Nettoyant

Uses advised against

Pas d'informations complémentaires disponibles

Manufacturers & Suppliers

Qlean-tec BV logo

Qlean-tec BV

national supplier

Groot Mijdrechtstraat 52, 3641 RW Mijdrecht, NL

0031 (0) 297 274390

http://www.qleantec.com

Emergency Contacts

National Poisons Information Centre National Institute for Public Health and the Environment

+31 30 274 88 88

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Skin Corr.

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

<5% phosphonates, polycarboxylates

Chemical Name CAS Number Concentration Hazardous
Hydroxyde de sodium EC: 215-185-5 1310-73-2 30 - 50% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Emmener la victime à l'air frais. Consulter un médecin si les difficultés respiratoires persistent.

Symptoms: Corrosif pour les voies respiratoires.

Skin contact

Enlever vêtements et chaussures contaminés. Rincer abondamment à l'eau.

Symptoms: Corrosif pour la peau.

Eye contact

Sans perdre de temps, rincer les yeux à l'eau courante pendant 15 minutes, en maintenant les paupières largement écartées. Appeler un médecin.

Symptoms: Corrosif pour les yeux.

Ingestion

NE PAS FAIRE VOMIR. Faire boire de l'eau. Consulter immédiatement un médecin.

Symptoms: Corrosif.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Non combustible. Tous les agents d'extinction sont utilisables.

Specific hazards

Vapeurs corrosives.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Eviter la pénétration dans les égouts, le sol et les eaux potables.

Cleanup methods

Nettoyer dès que possible tout épandage, en le récoltant au moyen d'un produit absorbant. Diluer les résidus et rincer.

Materials: produit absorbant

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Pas d'informations complémentaires disponibles

Storage

Conserver dans un endroit sec, frais et bien ventilé.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Gants.

Eyes

Porter un apparéil de protection des yeux/du visage.

Respiratory

En cas de ventilation insuffisante, porter un apparéil respiratoire approprié.

Skin/Body

Porter un vêtement de protection approprié.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor
Faible.
Voc Content
---
Auto Ignition Temperature
Non applicable.
Colour Intensity
---
Metal Corrosion
---
Solubility
---
Kinematic Viscosity
---
Cloud Point
---
Density
1,35 g/cm³
Upper Explosive Limit
---
Relative Evaporation Rate
---
Melting Point
---
Explosive Limits
---
Dynamic Viscosity
< 10 mPa.s
Physical State
Liquide
Softening Point
---
Bulk Density
---
Decomposition Temperature
---
Vapor Pressure
---
Relative Density
---
Boiling Point
---
Properties Status
---
Molecular Weight
---
Lower Explosive Limit
---
Vapor Density
---
Solubility In Fat
---
Solidification Point
---
Partition Coefficient
---
Solubility In Water
Miscible en toutes proportions
Ph
13,9
Evaporation Rate
---
Colour
Incolore.
Flammability
---
Freezing Point
---
Appearance
---
State Under Standard Conditions
---
Form
---
Physical State Data
liquid
Crystallisation Point
---
Flash Point
Aucun(e)
Odor Threshold
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable dans les conditions normales.

Reactivity

Réagit violemment avec : Acides.

Hazardous reactions

Pas d'informations complémentaires disponibles

Avoid

Pas d'informations complémentaires disponibles

Incompatible

Acides

Decomposition

Pas d'informations complémentaires disponibles

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1824
Shipping Name
HYDROXYDE DE SODIUM EN SOLUTION
Transport Class
8
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for R-Clean Relavit Forte?

The signal word is na: r-phrases.

What is the physical form of R-Clean Relavit Forte?

R-Clean Relavit Forte is a liquide with incolore. color. It has faible. odor.

What is R-Clean Relavit Forte used for?

Nettoyant