NextSDS Logo
Safety Data Sheet FR

Sikafloor®-02 Primer

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Sikafloor®-02 Primer

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Adhesifs

Manufacturers & Suppliers

S

Sika Belgium nv

manufacturer

Venecoweg 37 9810 Nazareth

+32 9 381 65 00

Emergency Contacts

Centre antipoison/antigifcentrum

070/245.245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
1,2-benzisothiazol-3(2H)-one EC: 220-120-9 2634-33-5 0.025 - 0.036% Yes
masse de réaction de 5-chloro-2-méthyl-2H-isothiazol-3-one et de 2-méthyl-2H-isothiazol-3-one (3:1) 55965-84-9 0.0002 - 0.0015% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Amener la victime à l'air libre.

Skin contact

Oter immédiatement les vêtements et les chaussures contaminés. Laver au savon avec une grande quantité d'eau.

Eye contact

Enlever les lentilles de contact. Maintenir l'oeil bien ouvert pendant le rinçage.

Ingestion

Ne pas faire vomir sans l'avis d'un médecin. Se rincer la bouche à l'eau. Ne pas faire boire de lait ou de boissons alcoolisées. Ne jamais rien faire avaler à une personne inconsciente.

Medical Treatment

Traiter de façon symptomatique.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

En cas d'incendie, utiliser de l'eau/ de l'eau pulverisée/ un jet d'eau/ l'oxyde de carbone/du sable/ de la mousse résistant à l'alcool/ du produit chimique pour l'extinction.

Instructions

Procédure standard pour feux d'origine chimique.

Firefighter Protection

En cas d'incendie, porter un appareil de protection respiratoire autonome.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Pas de précautions spéciales pour l'environnement requises.

Cleanup methods

Essuyer avec une matière absorbante (p.ex. tissu, laine).

Materials: matière absorbante (p.ex. tissu, laine)

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Pas de recommandations spéciales requises pour la manipulation. Suivez les mesures d'hygiène standards lors de la manipulation des produits chimiques

Storage

Tenir le récipient bien fermé dans un endroit sec et bien aéré. Stocker conformément aux réglementations locales.

Hygiene

Ne pas manger et ne pas boire pendant l'utilisation. Ne pas fumer pendant l'utilisation.

Fire prevention

Mesures préventives habituelles pour la protection contre l'incendie.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Maintenir les concentrations dans l'air au-dessous des standards d'exposition professionnelle. Assurer une ventilation adéquate, surtout dans les endroits clos.

Hands

Des gants résistants au produit chimique, imperméables (norme EN 374) doivent être portés en manipulant les produits chimiques. Gants en caoutchouc butyle/nitrile (> 0,1 mm) Recommandé: Gants en caoutchouc butyle/nitrile.

Eyes

Lunettes de sécurité

Respiratory

Lorsque la ventilation du local est insuffisante porter un équipement de protection respiratoire. Le choix de l'appareil de protection respiratoire doit être fondé sur les niveaux d'expositions prévus ou connus, les dangers du produit et les limites d'utilisation sans danger de l'appareil de protection respiratoire retenu. filtre de vapeurs organiques (Type A) A1: < 1000 ppm; A2: < 5000 ppm; A3: < 10000 ppm Le choix des protections respiratoires (EN 14387) doit être basé sur les concentrations connues ou estimées, la dangerosité du produit et les classes d'efficacité propres au masque respiratoire. Prévoyez une ventilation adéquate (ventilation générale ou extraction locale). (EN 689 - Méthodes pour l'évaluation de l'exposition aux agents chimiques). Applicable dans les zones de mélange et d'agitation. Dans le cas où il n'est pas possible de rester en dessous des seuils des valeurs limites d'exposition, les mesures de protections respiratoires doivent être utilisées.

Skin/Body

Vêtements de protection (ex : chaussures de Sécurité selon ISO 20345, vêtements de travail à manches longues, pantalon long). Le port de tabliers en caoutchouc et de bottines protectrices est recommandé en complément lors du mélange et de l'agitation.

Environmental

Pas de précautions spéciales pour l'environnement requises.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
liquide
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
bleu
Colour Intensity
---
Form
---
Odor
caractéristique
Odor Threshold
---
Ph
env. 9
Melting Point
Donnée non disponible
Boiling Point
100 °C
Flash Point
Non applicable
Freezing Point
Donnée non disponible
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
23 hPa
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
env. 1,38 g/cm³ (20 °C)
Flammability
Donnée non disponible
Upper Explosive Limit
Donnée non disponible
Lower Explosive Limit
Donnée non disponible
Explosive Limits
---
Auto Ignition Temperature
Donnée non disponible
Decomposition Temperature
Donnée non disponible
Solubility
---
Partition Coefficient
Donnée non disponible
Solubility In Water
dispersable
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
> 7 mm²/s (40 °C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Ce produit est chimiquement stable.

Reactivity

Pas de réactions dangereuses connues dans les conditions normales d'utilisation.

Hazardous reactions

Pas de dangers particuliers à signaler.

Avoid

Donnée non disponible

Incompatible

Donnée non disponible

Decomposition

On ne connaît pas de produits de décomposition dangereux.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicité

Composants:

12.1 Toxicité

1,2-benzisothiazol-3(2H)-one: Toxicité pour la daphnie et les autres invertébrés aquatiques : CE50 (Daphnia (Daphnie)): 3 mg/l Durée d'exposition: 48 h Facteur M (Toxicité aiguë pour le milieu aquatique) : 1 Facteur M (Toxicité chronique pour le milieu aquatique) : 1

12.1 Toxicité

masse de réaction de 5-chloro-2-méthyl-2H-isothiazol-3-one et de 2-méthyl-2H-isothiazol-3-one (3:1): Facteur M (Toxicité aiguë pour le milieu aquatique) : 100 Facteur M (Toxicité chronique pour le milieu aquatique) : 100

12.2 Persistance et dégradabilité

Donnée non disponible

12.3 Potentiel de bioaccumulation

Donnée non disponible

12.4 Mobilité dans le sol

Donnée non disponible

12.5 Résultats des évaluations PBT et vPvB

Evaluation : Cette substance/ce mélange ne contient aucun ingrédient considéré comme persistant, bio-accumulable et toxique (PBT), ou très persistant et très bio-accumulable (vPvB) à des niveaux de 0,1% ou plus..

Le produit ne contient aucun ingrédient considéré comme persistant, bio-accumulable et toxique (PBT), ou très persistant et très bio-accumulable (vPvB) à des niveaux de 0,1% ou plus.

12.6 Propriétés perturbant le système endocrinien

Evaluation : La substance/Le mélange ne contient pas de composants considérés comme ayant des propriétés perturbatrices du système endocrinien selon l'article 57(f) de REACH ou le règlement délégué de la Commission (UE) 2017/2100 ou le règlement de la Commission (EU) 2018/605 à des niveaux de 0,1 % ou plus.

La substance/Le mélange ne contient pas de composants considérés comme ayant des propriétés perturbatrices du système endocrinien à des niveaux de 0,1 % ou plus.

12.7 Autres effets néfastes

Information écologique supplémentaire : Il n'y a pas d'informations disponibles pour ce produit.

Il n'y a pas d'informations disponibles pour ce produit.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Élimination des produits excédentaires et non recyclables par une entreprise autorisée de collecte des déchets.

Disposal

Il est recommandé d'éviter ou réduire autant que possible la production de déchets. Ne se débarrasser de ce produit et de son récipient qu'en prenant toutes précautions d'usage.

Waste Codes

08 04 14 boues aqueuses contenant des colles et mastics autres que celles visées à la rubrique 08 04 13 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Toutes les substances contenues dans nos produits sont enregistrées par nos fournisseurs en amont, et/ou enregistrées par nous, et/ou exclues du règlement, et/ou exemptées d'enregistrement

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Sikafloor®-02 Primer?

The signal word is no signal word.

What is the physical form of Sikafloor®-02 Primer?

Sikafloor®-02 Primer is a liquide with bleu color. It has caractéristique odor.

What is Sikafloor®-02 Primer used for?

Adhesifs

What is the melting point of Sikafloor®-02 Primer?

The melting point is Donnée non disponible and the boiling point is 100 °C.