NextSDS Logo
Safety Data Sheet FR

RADIACID 0075

CAS 68002-88-0
EC 268-103-5

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RADIACID 0075
Product Form
Substance (UVCB)
Product Code
0075
Chemical Name
Fatty acids, C16-22 (even numbered)

Regulatory Identifiers

CAS Number
68002-88-0 Check regulations →
EC Number
268-103-5 Check regulations →
REACH No.
01-2119543710-46

Identified Uses

General overview of industrial uses of commercial fatty acids Supplementary overview of industrial uses of non classified commercial fatty acids Specific industrial uses of non classified commercial fatty acids General overview of professional uses of commercial fatty acids General overview of consumer uses of commercial fatty acids

Uses advised against

Pas d'informations complémentaires disponibles

Manufacturers & Suppliers

OLEON N.V. logo

OLEON N.V.

manufacturer

Assenedestraat 2, 9940 Ertvelde - Belgium

+32 9 341 10 11

http://www.oleon.com

Emergency Contacts

SGS ERS

+32 3 575 55 55

SGS ERS

+1 888 765 6554

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type uvcb
Chemical Name CAS Number Concentration Hazardous
Fatty acids, C16-22 EC: 268-103-5 68002-88-0 100% No

Textes des phrases H: voir section 16.

Notes

Textes des phrases H: voir section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Emmener la victime à l'air frais. Troubles respiratoires: consulter médecin/service médical.

Symptoms: EN CAS D'ECHAUFFEMENT: Irritation des voies respiratoires.

Skin contact

Rincer immédiatement et abondamment à l'eau. Du savon peut être utilisé. Consulter un médecin si l'irritation persiste.

Eye contact

Rincer immédiatement et abondamment à l'eau. Consulter un ophtalmologue si l'irritation persiste.

Ingestion

Rincer la bouche à l'eau. Consulter le centre anti-poison (www.who.int/ipcs/poisons/centre/directory/en). Consulter un médecin/le service médical en cas de malaise.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Mousse AFFF. Poudre BC. Acide carbonique. Sable sec. Poudre. Adapter les agents d'extinction à l'environnement.

Unsuitable media

L'eau (jet PLEIN) est inefficace pour l'extinction.

Specific hazards

DANGER D'INCENDIE DIRECT: Combustible. DANGER D'INCENDIE INDIRECT: En cas d'échauffement risque d'incendie accru. À température > point d'éclair. risque d'incendie/explosion accru.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Délimiter la zone de danger. Echauffement faire fermer portes et fenêtres par voisinage. En cas d'incendie/échauffement envisager l'évacuation. Nettoyer les vêtements contaminés.

Environmental

Empêcher la pollution du sol et de l'eau.

Cleanup methods

Recueillir soigneusement le solide répandu/les restes. Produit en fusion: laisser figer et ramasser ensuite. Mettre le solide répandu dans un récipient qui se referme ou dans sacs en plastique. Rincer les surfaces souillées abondamment à l'eau et solution savonneuse.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Température de manipulation : ≥ 10 °C au dessus du point de fusion

Storage

Conserver le récipient dans un endroit bien ventilé. Conserver à température ambiante. Conserver à l'abri des rayons solaires directs. Conforme à la réglementation.

Fire prevention

TENIR LE PRODUITA L'ECART DE: sources d'ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Gants. OFFRENT UNE BONNE RÉSISTANCE : caoutchouc nitrile

Eyes

Lunettes de sécurité

Skin/Body

Vêtements de protection

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Solide
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Selon la temp. ambiante : solide ou liquide.
Colour
Blanc à blanc cassé.
Colour Intensity
---
Form
---
Odor
Odeur caractéristique. Odeur faible.
Odor Threshold
Aucune donnée disponible
Ph
< 7
Melting Point
60 °C
Boiling Point
> 300 °C
Flash Point
ca. 180 °C (ASTM D92)
Freezing Point
ca. 60 °C (58-64)
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
Aucune donnée disponible
Evaporation Rate
---
Vapor Pressure
< 0,01 hPa (20°C)
Vapor Density
---
Relative Density
Aucune donnée disponible
Bulk Density
---
Density
0.85 to 0.90
Flammability
Aucune donnée disponible
Upper Explosive Limit
Aucune donnée disponible
Lower Explosive Limit
Aucune donnée disponible
Explosive Limits
---
Auto Ignition Temperature
ca. 350 °C
Decomposition Temperature
Aucune donnée disponible
Solubility
soluble dans la plupart des solvants organiques.
Partition Coefficient
> 5 (est.)
Solubility In Water
< 0,005 g/100ml (25°C)
Solubility In Fat
Soluble dans les huiles/graisses.
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
ca. 12 mm²/s (70°C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable dans les conditions normales.

Reactivity

En cas de combustion: libération de (monoxyde de carbone - dioxyde de carbone).

Hazardous reactions

Pas d'informations complémentaires disponibles

Avoid

Pas d'informations supplémentaires disponibles.

Incompatible

Pas d'informations supplémentaires disponibles.

Decomposition

Pas d'informations supplémentaires disponibles.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicité

Ecologie - général : Selon la littérature: aucun danger pour l'environnement. Ecologie - air : Pas d'informations supplémentaires disponibles. Ecologie - eau : Aucun renseignement disponible sur la bioaccumulation

12.2. Persistance et dégradabilité

12.2. Persistance et dégradabilité

| RADIACID 0075 (68002-88-0) | | | --- | --- | | DThO | 2,9 g O2/g matière |

12.3. Potentiel de bioaccumulation

12.3. Potentiel de bioaccumulation

12.3. Potentiel de bioaccumulation

| RADIACID 0075 (68002-88-0) | | | --- | --- | | Log Pow | > 5 (est.) |

12.4. Mobilité dans le sol

Tension de surface | ca. 0,03 N/m (20°C)
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Eliminer en centre de traitement agréé.

Disposal

Ne pas rejeter à l'égout ou dans l'environnement. Eliminer en centre de traitement agréé.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

RADIACID 0075 n'est pas sur la liste Candidate REACH, pas de restrictions selon l'annexe XVII de REACH, pas listé à l'Annexe XIV de REACH.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for RADIACID 0075?

The signal word is no signal word.

What is the physical form of RADIACID 0075?

RADIACID 0075 is a solide appearing as selon la temp. ambiante : solide ou liquide. with blanc à blanc cassé. color. It has odeur caractéristique. odeur faible. odor.

What is the solubility of RADIACID 0075?

soluble dans la plupart des solvants organiques.

What is RADIACID 0075 used for?

General overview of industrial uses of commercial fatty acids Supplementary overview of industrial uses of non classified commercial fatty acids Specific industrial uses of non classified commercial fatty acids General overview of professional uses of commercial fatty acids General overview of consumer uses of commercial fatty acids

What is the melting point of RADIACID 0075?

The melting point is 60 °C and the boiling point is > 300 °C.