01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE 570

Regulatory Identifiers

CAS Number
N/A
UFI Code
CK33-6039-P009-VEJP

Identified Uses

Anaérobie

Manufacturers & Suppliers

Henkel Belgium N.V. logo

Henkel Belgium N.V.

manufacturer

Esplanade 1, 1020 Brussels, Belgique

+32 (2) 421 2711

http://www.mysds.henkel.com

Emergency Contacts

Emergency Contact

+32 70 222 076

24 h

Centre Antipoisons en Belgique

+32 (0) 70 245245

7j/7j – 24h-24h

Centre Antipoisons

++352 8002 5500

7j/7j – 24h-24h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Eye Irrit. Cat. 2 H319
STOT SE Cat. 3 H335

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H319 Provoque une sévère irritation des yeux.
H335 Peut irriter les voies respiratoires.

Precautionary Statements

P101 En cas de consultation d'un médecin, garder à disposition le récipient ou l'étiquette.
P102 Tenir hors de portée des enfants.
P261 Éviter de respirer les vapeurs.
P337 + P313 Si l'irritation oculaire persiste: consulter un médecin.
P501 Éliminer le contenu/récipient conformément à la réglementation nationale.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hydroperoxyde de cumène EC: 201-254-7 80-15-9 1 - 3% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Amener au grand air. Si les symptomes persistent, faire appel à un médecin.

Symptoms: Irritation, toux, insuffisance respiratoire, oppression de la poitrine.

Skin contact

Rincer à l'eau courante et au savon. Si l'irritation persiste, consulter un médecin.

Symptoms: Un contact prolongé ou répété avec la peau peut entraîner une irritation cutanée.

Eye contact

Rincer immédiatement à l'eau courante (pendant 10 minutes), consulter un médecin.

Symptoms: Irritation, conjonctivite.

Ingestion

Rincer l'intérieur de la bouche, boire 1 à 2 verres d'eau, ne pas faire vomir, consulter un médecin.

Medical Treatment

Voir section: Description des premiers secours

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

eau, carbon dioxide, mousse, poudre

Unsuitable media

Jet d'eau grand débit

Specific hazards

En cas d'incendie, de l'oxyde de carbone (CO), du dioxyde de carbone (CO2) et de l'oxyde nitrique (NOx) risquent d'être dégagés.

Instructions

En cas d'incendie, refroidir les récipients exposés avec de l'eau vaporisée.

Firefighter Protection

Utiliser un appareil respiratoire autonome et une panoplie complète de protection telle qu'une tenue de nettoyage.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Eviter le contact avec la peau et les yeux. Porter un équipement de sécurité. Assurer une aération et une ventilation suffisantes. Tenir à l'écart de sources d'inflammation.

Small spill

Si la quantité renversée est peu importante, essuyer avec un papier absorbant et placer dans un récipient pour mise au rebut.

Large spill

Si la quantité renversée est importante, absorber dans un matériau absorbant inerte et placer le tout dans un récipient hermétiquement fermé pour mise au rebut.

Environmental

Ne pas laisser s'écouler dans les canalisations/les eaux superficielles/ les eaux souterraines.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Eviter le contact avec la peau et les yeux. Voir le conseil à la section 8.

Storage

Veiller à une bonne ventilation/aspiration. Se reporter à la Fiche Technique.

Hygiene

De bonnes pratiques d'hygiène industrielle devraient être respectées. Se laver les mains avant chaque pause et après le travail. Pendant le travail ne pas manger, boire, fumer.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Veiller à une bonne ventilation/aspiration.

Hands

Gants de protection résistant aux produits chimiques (EN 374) Matières appropriées à un contact de courte durée ou à des projections (recommandation: indice de protection au moins 2, soit > 30 minutes de temps de perméation selon EN 374): Caoutchouc nitrile (NBR; >= 0,4 mm d'épaisseur de couche) Matières appropriées également à un contact direct et plus long (recommandation: indice de protection 6, soit > 480 minutes de temps de perméation selon EN 374): Caoutchouc nitrile (NBR; >= 0,4 mm d'épaisseur de couche) Les indications faites sont basées sur la littérature et sur les informations fournies par les fabricants de gants ou sont déduites par analogie de matières similaires. Il faut tenir compte que la durée d'utilisation d'un gant de protection contre les produits chimiques dans la pratique peut être sensiblement plus courte que le temps de perméation déterminé selon EN 374 en raison de multiples facteurs d'influence (comme la température p. ex.). Le gant doit être remplacé s'il présente des signes d'usure.

Eyes

Des lunettes de sécurité avec protections latérales ou des lunettes desécurité pour produits chimiques devraient être portées s'il y a un riqued'éclaboussures. L'équipement de protection pour les yeux doit être conforme à la norme EN166.

Respiratory

Assurer une aération et une ventilation suffisantes. Il convient de porter un masque agréé ou un respirateur avec unecartouche de vapeur organique si le produit est utilisé dans un endroitmal ventilé. Type de filtre: A (EN 14387)

Skin/Body

Porter un vêtement de protection approprié. Les vêtements de protection doivent être conformes à la norme EN14605 en cas d'éclaboussures de liquide, et à la norme EN13982 en cas d'exposition aux poussières.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquide
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Ambré
Colour Intensity
---
Form
liquide
Odor
Acrylique
Odor Threshold
---
Ph
Non applicable, Le produit est non polaire/aprotique.
Melting Point
Non applicable, Le produit est un liquide.
Boiling Point
> 150 °C (> 302 °F)
Flash Point
> 100 °C (> 212 °F)
Freezing Point
---
Softening Point
---
Solidification Point
< -30 °C (< -22 °F)
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
< 0,67 mbar (25 °C (77 °F)); < 0,13 mbar (20 °C (68 °F))
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1,08 g/cm3 Néant (20 °C (68 °F))
Flammability
Le produit n'est pas inflammable.
Upper Explosive Limit
Non applicable, Le produit n'est pas inflammable.
Lower Explosive Limit
Non applicable, Le produit n'est pas inflammable.
Explosive Limits
---
Auto Ignition Temperature
Non applicable, Le produit n'est pas inflammable.
Decomposition Temperature
Non applicable, La substance/le mélange n'est pas autoréactif, ne contient pas de peroxyde organique et ne se décompose pas dans les conditions d'utilisation prévues
Solubility
Miscible (Solv.: Acétone); Légère (20 °C (68 °F); Solv.: Eau)
Partition Coefficient
Non applicable (Mélange)
Solubility In Water
Légère (20 °C (68 °F); Solv.: Eau)
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
> 20,5 mm2/s (40 °C (104 °F))
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable dans les conditions recommandées de stockage.

Reactivity

Réagit avec les oxydants forts. Des acides. Agents réducteurs. Des bases fortes.

Hazardous reactions

Voir section réactivité

Avoid

Stable dans des conditions normales d'entreposage et d'utilisation.

Incompatible

Voir section réactivité.

Decomposition

oxydes de carbone, Hydrocarbures, oxydes d'azote

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Toxicité pour les microorganismes

Toxicité pour les microorganismes: | Substances dangereuses No. CAS | Valeur type | Valeur | Temps d'exposition | Espèces | Méthode | | Hydroperoxyde de cumène 80-15-9 | EC10 | 70 mg/l | 30 mn | non spécifié | non spécifié |

12.1. Toxicité

| Substances dangereuses No. CAS | Valeur type | Valeur | Temps d'exposition | Espèces | Méthode | | Hydroperoxyde de cumène 80-15-9 | LC50 | 3,9 mg/l | 96 h | Oncorhynchus mykiss | OECD Guideline 203 (Fish, Acute Toxicity Test) |

12.1. Toxicité

12.1. Toxicité | Substances dangereuses No. CAS | Valeur type | Valeur | Temps d'exposition | Espèces | Méthode | | Hydroperoxyde de cumène 80-15-9 | EC50 | 18,84 mg/l | 48 h | Daphnia magna | OECD Guideline 202 (Daphnia sp. Acute Immobilisation Test) | Toxicité chronique pour les invertébrés aquatiques: Il n'y a pas de données disponibles. Toxicité (Algues): La classification du mélange est basée sur La méthode de calcul selon La teneur des substances classées contenues dans La formule. Le tableau ci-dessous présente les données des substances classifiées présentes dans le mélange. | Substances dangereuses No. CAS | Valeur type | Valeur | Temps d'exposition | Espèces | Méthode | | --- | --- | --- | --- | --- | --- | | Hydroperoxyde de cumène 80-15-9 | EC50 | 3,1 mg/l | 72 h | Desmodesmus subspicatus (reported as Scenedesmus subspicatus) | OECD Guideline 201 (Alga, Growth Inhibition Test) | | Hydroperoxyde de cumène 80-15-9 | NOEC | 1 mg/l | 72 h | Desmodesmus subspicatus (reported as Scenedesmus subspicatus) | OECD Guideline 201 (Alga, Growth Inhibition Test) |

Toxicité pour les microorganismes

La classification du mélange est basée sur La méthode de calcul selon La teneur des substances classées contenues dans La formule. Le tableau ci-dessous présente les données des substances classifiées présentes dans le mélange. | Substances dangereuses No. CAS | Valeur type | Valeur | Temps d'exposition | Espèces | Méthode | | --- | --- | --- | --- | --- | --- |

La classification du mélange est basée sur La méthode de calcul selon La teneur des substances classées contenues dans La formule.

12.2. Persistance et dégradabilité

Le tableau ci-dessous présente les données des substances classifiées présentes dans le mélange. | Substances dangereuses No. CAS | Résultat | Type de test | Dégradabilité | Temps d'exposition | Méthode | | --- | --- | --- | --- | --- | --- |

12.2. Persistance et dégradabilité

| Substances dangereuses No. CAS | Résultat | Type de test | Dégradabilité | Temps d'exposition | Méthode | | Hydroperoxyde de cumène 80-15-9 | Non facilement biodégradable. | aérobie | 3 % | 28 Jours | OECD Guideline 301 B (Ready Biodegradability: CO2 Evolution Test) |

12.3. Potentiel de bioaccumulation

| Substances dangereuses No. CAS | Facteur de bioconcentration (BCF) | Temps d'exposition | Température | Espèces | Méthode | | Hydroperoxyde de cumène 80-15-9 | 9,1 | | | Calcul | OECD Guideline 305 (Bioconcentration: Flow-through Fish Test) |

12.4. Mobilité dans le sol

Le tableau ci-dessous présente les données des substances classifiées présentes dans le mélange. | Substances dangereuses No. CAS | LogPow | Température | Méthode | | --- | --- | --- | --- | | Hydroperoxyde de cumène 80-15-9 | 1,6 | 25 °C | OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method) |

12.5. Résultats des évaluations PBT et vPvB

Le tableau ci-dessous présente les données des substances classifiées présentes dans le mélange. | Substances dangereuses No. CAS | PBT / vPvB | | --- | --- | | Hydroperoxyde de cumène 80-15-9 | Ne remplit pas les critères : Persistant, Bioaccumulable et Toxique (PBT), Très Persistant et Très Bioaccumulable (vPvB). |

La substance Hydroperoxyde de cumène (80-15-9) ne remplit pas les critères PBT ou vPvB.

12.6. Propriétés perturbant le système endocrinien

Non applicable

12.7. Autres effets néfastes

Il n'y a pas de données disponibles.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Ne pas laisser s'écouler dans les canalisations/les eaux superficielles/ les eaux souterraines. Eliminer conformément aux réglementations locales et nationales.

Disposal

Eliminer conformément aux réglementations locales et nationales.

Waste Codes

08 04 09* adhésifs et agents d'étanchéité rejetés contenant des solvants organiques et autres substances dangereuses EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE 570?

The signal word is warning.

What is the physical form of LOCTITE 570?

LOCTITE 570 is a liquide with ambré color. It has acrylique odor.

What is the solubility of LOCTITE 570?

Miscible (Solv.: Acétone); Légère (20 °C (68 °F); Solv.: Eau)

What is LOCTITE 570 used for?

Anaérobie

What are the hazard statements for LOCTITE 570?

This substance has 2 hazard statements:

  • H319: Provoque une sévère irritation des yeux.
  • H335: Peut irriter les voies respiratoires.

What is the melting point of LOCTITE 570?

The melting point is Non applicable, Le produit est un liquide. and the boiling point is > 150 °C (> 302 °F).