NextSDS Logo
Jo

Joint Finish

NO SIGNAL WORD Liquide SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Joint Finish
Product Form
Mélange

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Utilisation professionnelle, Utilisation par les consommateurs
Uses Advised Against
Pas d'informations complémentaires disponibles

Overview

Joint Finish is a liquide. substance commonly used utilisation professionnelle, utilisation par les consommateurs.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Soudal N.V. company logo - Safety Data Sheet supplier organization

Soudal N.V.

manufacturer

📍

Everdongenlaan 18-20, 2300 Turnhout, Belgium

🌍

BE

📞

+32 14 42 42 31

📠

+32 14 42 65 14

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

ORFILA

📞

+33 1 45 42 59 59

🌍

FR

🕒

24 heures sur 24 et 7 jours sur 7

💡

Ce numéro permet d'obtenir les coordonnées de tous les centres Anti- poison Français. Ces centres anti-poison et de toxicovigilance fournissent une aide médicale gratuite (hors coût d'appel)

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
GEETHOXYLEERD
EC: 220-120-9
2634-33-5 0.05-100% ⚠️ Hazardous
masse de réaction de 5-chloro-2-methyl-2H-isothiazol-3-one et de 2-methyl-2H-isothiazol-3-one (3:1)
EC: 611-341-5
55965-84-9 0.0015-100% ⚠️ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Transporter la personne à l'extérieur et la maintenir dans une position où elle peut confortablement respirer.

Symptoms:

Troubles respiratoires

🖐️ Skin Contact

Rincer la peau à l'eau/se doucher.

Symptoms:

irritation ou d'éruption cutanée

👁️ Eye Contact

Rincer les yeux à l'eau par mesure de précaution. Enlever les lentilles de contact si la victime en porte et si elles peuvent être facilement enlevées. Continuer à rincer.

Symptoms:

irritation persiste

🍽️ Ingestion/Swallowing

Rincer la bouche à l'eau.

Symptoms:

malaise

🚨 Immediate Medical Attention Required

En cas de malaise, troubles respiratoires, irritation ou éruption cutanée, ou si l'irritation oculaire persiste, consulter un médecin/service médical/ophtalmologue.

Medical Treatment

Traitement symptomatique.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

💨 Evaporation Rate
Not available
📊 Form
Not available
📊 Metal Corrosion
Not available
📊 Auto Ignition Temperature
Not available
📊 Vapor Density
Not available
📊 Upper Explosive Limit
Not available
📊 Solubility In Fat
Not available
📊 Dynamic Viscosity
Not available
📊 Relative Evaporation Rate
Not available
📊 Properties Status
Not available
🎨 Colour
Incolore.
🔥 Flammability
Non applicable
📊 Solubility In Water
Not available
📊 Freezing Point
Not available
📊 Explosive Limits
Not available
👃 Odor
caractéristique.
🧊 Melting Point
Non applicable
Critical Property
📊 Solidification Point
Not available
📊 Molecular Weight
Not available
📊 Colour Intensity
Not available
💨 Boiling Point
Not available
💧 Solubility
Not available
💨 Vapor Pressure
Not available
📊 Crystallisation Point
Not available
📊 Relative Density
Not available
📊 Cloud Point
Not available
🧪 Physical State
Liquide
Critical Property
📊 State Under Standard Conditions
Not available
📊 Kinematic Viscosity
Not available
⚖️ Density
1,005 kg/m3
Critical Property
📊 Decomposition Temperature
Not available
📊 Physical State Data
liquid
👁️ Appearance
Liquide.
📊 Lower Explosive Limit
Not available
📊 Softening Point
Not available
📊 Odor Threshold
Not available
📊 Bulk Density
Not available
📊 Voc Content
0,69 % (6.93 g/l)
🔥 Flash Point
Not available
🧪 Ph
Not available
📊 Partition Coefficient
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Assurer une bonne ventilation du poste de travail.

🧤 Hand Protection

Gants de protection

👁️ Eye Protection

Lunettes de sécurité

😷 Respiratory Protection

En cas de ventilation insuffisante, porter un appareil respiratoire approprié

🦺 Skin/Body Protection

Porter un vêtement de protection approprié

🌍 Environmental Exposure Controls

Éviter le rejet dans l'environnement.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

Non réglementé

📦 Proper Shipping Name

Non réglementé

⚠️ Transport Hazard Class

Non réglementé

📋 Packing Group

Non réglementé

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Joint Finish?

The signal word for this substance is "no signal word".

What is the physical form of Joint Finish?

Joint Finish is a liquide appearing as liquide. with incolore. color. It has caractéristique. odor.

What is Joint Finish used for?

Utilisation professionnelle, Utilisation par les consommateurs

What is the melting point of Joint Finish?

The melting point is Non applicable .