NextSDS Logo
V3

V33 TINT PARKET/TEINTE PARQUET DECO Blanc/Gris léger/Gris fumé

DANGER Liquide Fluide SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
V33 TINT PARKET/TEINTE PARQUET DECO Blanc/Gris léger/Gris fumé
Product Code
1215

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Peinture, vernis et produits connexes de revêtement avec application en couches.

Overview

V33 TINT PARKET/TEINTE PARQUET DECO Blanc/Gris léger/Gris fumé commonly used peinture, vernis et produits connexes de revêtement avec application en couches..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (DANGER)

Hazard Classifications

Flam. Liq. Category 2 H225
Eye Irrit. Category 2 H319
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Liquide et vapeurs très inflammables.
  • H319: Provoque une sévère irritation des yeux.
  • H336: Peut provoquer somnolence ou vertiges.

Precautionary Statements

  • P101: En cas de consultation d'un médecin, garder à disposition le récipient ou l'étiquette.
  • P102: Tenir hors de portée des enfants.
  • P210: Tenir à l'écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
  • P271: Utiliser seulement en plein air ou dans un endroit bien ventilé.
  • P501: Éliminer le contenu/récipient dans une déchetterie (contacter la collectivité locale).

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

V33 BELGIUM sprl. company logo - Safety Data Sheet supplier organization

V33 BELGIUM sprl.

manufacturer

📍

Ambachtenstraat 11.B-3210.LUBBEEK.BELGIQUE.

🌍

BE

📞

(+32) 16 629 292

📠

(+32) 16 621 970

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Centre Antipoisons / Antigifcentrum

📞

070/245 245

🌍

BE

BNPC Nancy

📞

03 83 32 36 36

🌍

FR

Centre Suisse d'information Toxicologique

📞

Tél 145

🌍

CH

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Propylene Glycol Monomethyl Ether
EC: 203-539-1
107-98-2 10-25% ⚠️ Hazardous
Etanol
EC: 200-578-6
64-17-5 10-25% ⚠️ Hazardous
Titanium dioxide (synthetic)
EC: 236-675-5
13463-67-7 10-25% ✓ Non-hazardous
XYLENE; MELANGE ISOMERES O,M,P
EC: 215-535-7
1330-20-7 2.5-10% ⚠️ Hazardous
4-hydroxy- 4-methylpentaan-2-on
EC: 204-626-7
123-42-2 2.5-10% ⚠️ Hazardous
acétate de 2-méthoxy- 1-méthyléthyle
EC: 204-658-1
123-86-4 2.5-10% ⚠️ Hazardous
DIACETONE-ALCOOL
EC: 200-661-7
67-63-0 2.5% ⚠️ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

En cas d'inhalation massive, transporter le patient à l'air libre, le garder au chaud et au repos. Si la personne est inconsciente, la placer en position latérale de sécurité. Avertir un médecin dans tous les cas pour juger de l'opportunité d'une surveillance et d'un traitement symptomatique en milieu hospitalier. Si la respiration est irrégulière ou arrêtée, pratiquer la respiration artificielle et faire appel à un médecin.

👁️ Eye Contact

Laver abondamment avec de l'eau douce et propre durant 15 minutes en maintenant les paupières écartées. S'il apparaît une douleur, une rougeur ou une gêne visuelle, consulter un ophtalmologiste.

🍽️ Ingestion/Swallowing

En cas d'ingestion, si la quantité est peu importante, (pas plus d'une gorgée), rincer la bouche avec de l'eau et consulter un médecin. Garder au repos. Ne pas faire vomir. Consulter un médecin en lui montrant l'étiquette. En cas d'ingestion accidentelle appeler un médecin pour juger de l'opportunité d'une surveillance et d'un traitement ultérieur en milieu hospitalier, si besoin est. Montrer l'étiquette.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Liquide Fluide
Critical Property
📊 Physical State Data
liquid
📊 State Under Standard Conditions
Not available
👁️ Appearance
Not available
🎨 Colour
Not available
📊 Colour Intensity
Not available
📊 Form
Not available
👃 Odor
Not available
📊 Odor Threshold
Not available
🧪 Ph
Non concerné
🧊 Melting Point
Non concerné
Critical Property
💨 Boiling Point
> 35°C
Critical Property
🔥 Flash Point
PE < 23°℃
Critical Property
📊 Freezing Point
Non concerné
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Not available
💨 Vapor Pressure
Non concerné
📊 Vapor Density
Not available
📊 Relative Density
Not available
📊 Bulk Density
Not available
⚖️ Density
0.8-0.9
Critical Property
🔥 Flammability
Not available
📊 Upper Explosive Limit
Not available
📊 Lower Explosive Limit
Not available
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
Not available
📊 Decomposition Temperature
Non concerné
💧 Solubility
Insoluble
📊 Partition Coefficient
Not available
📊 Solubility In Water
Insoluble
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
Not available
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
Not available
📊 Kinematic Viscosity
Not available
📊 Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Assurer une ventilation adéquate, surtout dans les endroits clos.

🧤 Hand Protection

Utiliser des gants de protection appropriés résistants aux agents chimiques conformes à la norme NF EN374. La sélection des gants doit être faite en fonction de l'application et de la durée d'utilisation au poste de travail. Les gants de protection doivent être choisis en fonction du poste de travail : autres produits chimiques pouvant être manipulés, protections physiques nécessaires (coupure, piqûre, protection thermique), dextérité demandée. Type de gants conseillés : Caoutchouc Butyle (Copolymère isobutylène-isoprène). Gants imperméables conformes à la norme NF EN374.

👁️ Eye Protection

Eviter le contact avec les yeux. Utiliser des protections oculaires conçues contre les projections de liquide. Avant toute manipulation, il est nécessaire de porter des lunettes à protection latérale conformes à la norme NF EN166. En cas de danger accru, utiliser un écran facial pour la protection du visage. Le port de lunettes correctrices ne constitue pas une protection. Il est recommandé aux porteurs de lentilles de contact d'utiliser des verres correcteurs lors des travaux où ils peuvent être exposés à des vapeurs irritantes. Prévoir des fontaines oculaires dans les ateliers où le produit est manipulé de façon constante.

😷 Respiratory Protection

Eviter l'inhalation des vapeurs. En cas de ventilation insuffisante, porter un appareil respiratoire approprié. Lorsque les travailleurs sont confrontés à des concentrations supérieures aux limites d'exposition, ils doivent porter un appareil de protection respiratoire appropriés et agréés. Filtre(s) anti-gaz et vapeurs (Filtres combinés) conforme(s) à la norme NF EN14387 : A1 (Marron).

🦺 Skin/Body Protection

Le personnel portera un vêtement de travail régulièrement lavé. Après contact avec le produit, toutes les parties du corps souillées devront être lavées.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

1263

📦 Proper Shipping Name

PEINTURES (y compris peintures, laques, émaux, couleurs, shellac, vernis, cirages, encaustiques, enduits d'apprêt et bases liquides pour laques) ou MATIÈRES APPARENTÉES AUX PEINTURES (y compris solvants et diluants pour peintures)

⚠️ Transport Hazard Class

3

📋 Packing Group

II

🚢 IMDG Maritime Transport Precautions

F-E,S-E

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for V33 TINT PARKET/TEINTE PARQUET DECO Blanc/Gris léger/Gris fumé?

The signal word for this substance is "danger".

What is the physical form of V33 TINT PARKET/TEINTE PARQUET DECO Blanc/Gris léger/Gris fumé?

V33 TINT PARKET/TEINTE PARQUET DECO Blanc/Gris léger/Gris fumé is a liquide fluide .

What is the solubility of V33 TINT PARKET/TEINTE PARQUET DECO Blanc/Gris léger/Gris fumé?

Insoluble

What is V33 TINT PARKET/TEINTE PARQUET DECO Blanc/Gris léger/Gris fumé used for?

Peinture, vernis et produits connexes de revêtement avec application en couches.

What are the hazard statements for V33 TINT PARKET/TEINTE PARQUET DECO Blanc/Gris léger/Gris fumé?

This substance has 3 hazard statements: H225: Liquide et vapeurs très inflammables. H319: Provoque une sévère irritation des yeux. H336: Peut provoquer somnolence ou vertiges.

What is the melting point of V33 TINT PARKET/TEINTE PARQUET DECO Blanc/Gris léger/Gris fumé?

The melting point is Non concerné and the boiling point is > 35°C.