NextSDS Logo
MO

MOTIP INDUSTRIAL COATING ZINKSPRAY

DANGER Aërosol SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
MOTIP INDUSTRIAL COATING ZINKSPRAY
Product Code
07301

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Verf
Uses Advised Against
Geen verdere relevante informatie verkrijgbaar.

Overview

MOTIP INDUSTRIAL COATING ZINKSPRAY is a volgens de produktbeschrijving substance commonly used verf.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Aerosol Category 1 H222
Aquatic Acute Category 1 H400
Aquatic Chronic Category 1 H410

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
  • H229: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
  • H400: Zeer giftig voor in het water levende organismen.
  • H410: Zeer giftig voor in het water levende organismen, met langdurige gevolgen.

Precautionary Statements

  • P102: Buiten het bereik van kinderen houden.
  • P260: Spuitnevel niet inademen.
  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
  • P251: Ook na gebruik niet doorboren of verbranden.
  • P211: Niet in een open vuur of op andere ontstekingsbronnen spuiten.
  • P410+P412: Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 ℃.
  • P501: De inhoud en de verpakking verwerken volgens de plaatselijke voorschriften.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

MOTIP DUPLI B.V.

manufacturer

📍

Wolfraamweg 2, NL-8471 XC Wolvega, Nederland

🌍

NL

📞

+31 (0)561 694400

📠

+31 (0)561 694411

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

+31 (0)561-694400

🌍

NL

🕒

tijdens kantooruren

NVIC

📞

030-2748888

🌍

NL

🕒

24 uur per dag

💡

Uitsluitend bestemd om artsen te informeren bij acute vergiftigingen

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mengsel van na elkaar aangevoerde stoffen met ongevaarlijke bijmengingen.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
dimethylether
EC: 204-065-8
115-10-6 25-50% ⚠️ Hazardous
zinkpoeder -zinkstof (gestabiliseerd)
EC: 231-175-3
7440-66-6 25-50% ⚠️ Hazardous
aceton
EC: 200-662-2
67-64-1 5-10% ⚠️ Hazardous
Oplosmiddelnafta (aardolie), lichte aromatische
EC: 918-668-5
64742-95-6 2.5-5% ⚠️ Hazardous
xyleen
EC: 215-535-7
1330-20-7 2.5-5% ⚠️ Hazardous
zinkoxide
EC: 215-222-5
1314-13-2 1-2.5% ⚠️ Hazardous
Fatty acids, tall-oil, compds. with oleylamine
EC: 288-315-1
85711-55-3 0.1% ⚠️ Hazardous

Additional Information

De woordelijke inhoud van de opgegeven aanwijzingen inzake de mogelijke gevaren is te vinden in hoofdstuk 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Frisse lucht toedienen; bij klachten arts ontbieden.

👁️ Eye Contact

De ogen gedurende verscheidene minuten onder stromend water afspoelen terwijl de oogspleet geopend blijft. Bij aanhoudende klachten een dokter raadplegen.

🍽️ Ingestion/Swallowing

Drink zeer veel water en voer verse lucht aan. Onmiddellijk een dokter waarschuwen.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

CO2, bluspoeder of waterstraal. Grotere brand met waterstraal bestrijden of met schuim, dat tegen alcohol bestand is.

Unsuitable Extinguishing Media

Krachtige waterstraal

⚠️ Specific Fire Hazards

Geen verdere relevante informatie verkrijgbaar.

🛡️ Firefighter Protection Equipment

Geen bijzondere maatregelen nodig.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

🌍 Environmental Precautions

Mag niet in riolering of afvalwater terechtkomen. Bij indringen in afvalwater of riolering moet de bevoegde instantie gewaarschuwd worden. Niet in de riolering/het oppervlaktewater/het grondwater laten terechtkomen.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Aërosol
Critical Property
📊 Physical State Data
Not available
📊 State Under Standard Conditions
Not available
👁️ Appearance
Volgens de produktbeschrijving
🎨 Colour
Volgens de produktbeschrijving
📊 Colour Intensity
Not available
📊 Form
Aërosol
👃 Odor
Karakteristiek
📊 Odor Threshold
Niet bepaald.
🧪 Ph
Niet bepaald.
🧊 Melting Point
Niet bepaald.
Critical Property
💨 Boiling Point
Vanwege aerosol niet bruikbaar.
Critical Property
🔥 Flash Point
<0 ℃ Vanwege aerosol niet bruikbaar.
Critical Property
📊 Freezing Point
Not available
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Niet bruikbaar.
💨 Vapor Pressure
4000 hPa
📊 Vapor Density
Niet bepaald.
📊 Relative Density
Niet bepaald.
📊 Bulk Density
Not available
⚖️ Density
1,095 g/cm3
Critical Property
🔥 Flammability
Het produkt is niet ontploffingsgevaarlijk, maar de vorming van ontploffingsgevaarlijke damp-/luchtmengsels is mogelijk.
📊 Upper Explosive Limit
26,2 Vol %
📊 Lower Explosive Limit
3,3 Vol %
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
240 °℃
📊 Decomposition Temperature
Niet bepaald.
💧 Solubility
Niet resp. gering mengbaar.
📊 Partition Coefficient
Niet bepaald.
📊 Solubility In Water
Niet resp. gering mengbaar.
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
648,5 g/l
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
Not available
📊 Kinematic Viscosity
Not available
📊 Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

⚠️ Handling Precautions

• Geen bijzondere maatregelen noodzakelijk.

• Voor goede ventilatie/afzuiging op de werkplaatsen zorgen.

• Nietspuiten in de richting van een vlam of een gloeiend voorwerp.

• Onststekingsbronnen op afstand houden - niet roken.

• Maatregelen treffen tegen ontlading van statische elektriciteit.

• Houder onder druk.

• Beschermen tegen de zon en niet blootstellen aan een hogere temperatuur dan 50 ℃, bijv.

• door gloeilampen.

• Ook na gebruik niet doorboren of verbranden.

🏪 Storage Conditions

• Op een koele plaats bewaren.

• Tegen hitte en directe zonnestralen beschermen.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🧤 Hand Protection

Niet noodzakelijk.

👁️ Eye Protection

Niet noodzakelijk.

😷 Respiratory Protection

Niet noodzakelijk.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Geen afbraak bij gebruik volgens voorschrift.

⚠️ Hazardous Reactions

Geen gevaarlijke reacties bekend.

🚫 Conditions to Avoid

Geen verdere relevante informatie verkrijgbaar.

🧪 Incompatible Materials

Geen verdere relevante informatie verkrijgbaar.

💨 Hazardous Decomposition Products

Geen gevaarlijke ontbindingsprodukten bekend.

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

🌱 Toxiciteit

Aquatische toxiciteit: 115-10-6 dimethylether EC50 / 48 h >4000 mg/l (daphnia magna) 7440-66-6 zinkpoeder -zinkstof (gestabiliseerd) EC50 / 48 h 2,8 mg/l (daphnia magna) 0,57 mg/l (daphnia magna) LC50 / 96 h 67-64-1 aceton EC50 / 48 h 8800 mg/l (daphnia magna) LC50 / 48 h 2262 mg/l (daphnia magna) LC50 / 96 h (statisch) 5540 mg/l (fish) 64742-95-6 Oplosmiddelnafta (aardolie), lichte aromatische EC50 / 24 h 150 mg/l (daphnia magna) EC50 / 48 h 7,4 mg/l (daphnia magna) LC50 / 96 h 3,77 mg/l (fish) 1330-20-7 xyleen EC50 / 48 h 7,4 mg/l (daphnia magna) 13,5 mg/l (fish) 64742-95-6 Oplosmiddelnafta (aardolie), lichte aromatische EC50 / 24 h 150 mg/l (daphnia magna) EC50 / 48 h 7,4 mg/l (daphnia magna) LC50 / 96 h 3,77 mg/l (fish) 1314-13-2 zinkoxide LC50 2,5 mg/l (muis) 85711-55-3 Fatty acids, tall-oil, compds. with oleylamine EC50 / 48 h 1,3 mg/l (daphnia magna)
Zeer giftig voor vissen.

🌱 Persistentie en afbreekbaarheid

Geen verdere relevante informatie verkrijgbaar.

🌱 Bioaccumulatie

Geen verdere relevante informatie verkrijgbaar.

🌱 Mobiliteit in de bodem

Geen verdere relevante informatie verkrijgbaar.

🌱 Resultaten van PBT- en zPzB-beoordeling

PBT: Niet bruikbaar. zPzB: Niet bruikbaar.

🌱 Andere schadelijke effecten

Geen verdere relevante informatie verkrijgbaar.

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

♻️ Waste Treatment Methods

Aanbeveling: Mag niet tezamen met huisvuil gestort worden of in de riolering terechtkomen.

🏷️ Waste Classification Codes

08 01 11* afval van verf en lak dat organische oplosmiddelen of andere gevaarlijke stoffen bevat EWC
15 01 04 metalen verpakking EWC

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN1950

📦 Proper Shipping Name

SPUITBUSSEN, MILIEUGEVAARLIJK

⚠️ Transport Hazard Class

2

🚛 ADR Transport Precautions

Waarschuwing: Gassen

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for MOTIP INDUSTRIAL COATING ZINKSPRAY?

The signal word for this substance is "danger".

What is the physical form of MOTIP INDUSTRIAL COATING ZINKSPRAY?

MOTIP INDUSTRIAL COATING ZINKSPRAY is a aërosol appearing as volgens de produktbeschrijving with volgens de produktbeschrijving color. It has karakteristiek odor.

What is the solubility of MOTIP INDUSTRIAL COATING ZINKSPRAY?

Niet resp. gering mengbaar.

What is MOTIP INDUSTRIAL COATING ZINKSPRAY used for?

Verf

What are the hazard statements for MOTIP INDUSTRIAL COATING ZINKSPRAY?

This substance has 4 hazard statements: H222: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting. H229: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting. H400: Zeer giftig voor in het water levende organismen. H410: Zeer giftig voor in het water levende organismen, met langdurige gevolgen.

What is the melting point of MOTIP INDUSTRIAL COATING ZINKSPRAY?

The melting point is Niet bepaald. and the boiling point is Vanwege aerosol niet bruikbaar..