Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MPM Automatic Transmission Flush
- Product Form
- Mengsel
- Product Code
- AD15000
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- 8J1U-QS9A-U10D-YGNP
Identified Uses
Onderhoudsproducten voor de automobielindustrie
Uses advised against
Geen aanvullende informatie beschikbaar.
Manufacturers & Suppliers
MPM International Oil Company
Cyclotronweg 1, 2629 HN Delft - Nederland
+31 (0)15 2514030
https://www.mpmoil.com
Emergency Contacts
Emergency Contact
+31 (0)15 2514030
08.00 - 17.00 GMT+1
Centre Anti-Poisons/Antigifcentrum c/o Hôpital Militaire Reine Astrid
+32 70 245 245
Nationaal Vergiftigingen Informatie Centrum (NVIC)
+31 88 755 80 00
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Hoog geraffineerde olie, bevat <3% (w/w) DMSO extract, bepaald volgens IP346.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Destillaten (aardolie), met waterstof behandelde lichte naftenische. EC: 265-156-6 | 64742-53-6 | 60 - 80% | Yes |
| Smeeroliën (aardolie), C20-50-, uit met waterstof behandelde neutrale olie verkregen EC: 276-738-4 | 72623-87-1 | 25 - 40% | Yes |
| Amines, polyethyleenpoly-, reactieproducten met barnsteenzuurhydride polyisobutenyl derivaten EC: 617-593-2 | 84605-20-9 | 3 - 5% | Yes |
| Highly refined mineral oil (C15 -C50) | 64742-65-0 | 1 - 3% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
De persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen.
Symptoms: Kan bij inademing allergie- of astmasymptomen of ademhalingsmoeilijkheden veroorzaken.
De besmette kleding uittrekken, de blootgestelde huid wassen met milde zeep en water en vervolgens afspoelen met warm water.
Symptoms: Wordt in normale gebruiksomstandigheden niet geacht een ernstig risico voor de huid met zich mee te brengen. Herhaalde of lange kontakten kan huidontvetting of -uitdroging veroorzaken en leiden tot ongemak en dermatitis. Langdurige of herhaalde blootstelling kan de huid echter ontvetten en tot dermatitis leiden. Hoge druk injectie van het product onder de huid kan zeer ernstige gevolgen hebben, zelfs zonder duidelijke symptomen of verwondingen.
Voorzichtig afspoelen met water gedurende een aantal minuten. Bij aanhoudende oogirritatie: een arts raadplegen.
Symptoms: Veroorzaakt irritatie van de ogen.
De mond spoelen. GEEN braken opwekken. Onmiddellijk een ANTIGIFCENTRUM/arts raadplegen. Gevaar bij inademing. Ga in de open lucht en verlucht de desbetreffende zone.
Symptoms: Inslikken kan misselijkheid, braken en diarree veroorzaken. Indringing in de longen bij inname of braken kan ernstige longschade veroorzaken.
Immediate Medical Attention
Inslikken van de vloeistof kan inademing in de longen veroorzaken met het risico op een chemische longontsteking. Symptomen van ademhalingsproblemen (longoedeem) kunnen na verschillende uren optreden.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
MPM Engine Flush
UFI: GQ0U-NSDC-S10F-C2U1
MPM Radiator Flush
UFI: GE2U-SS69-W10A-KWGA
MPM ATF Automatic Transmission Fluid FM+
---
MPM Automatic Transmission Fluid High Torque
---
MPM ATF AutomaticTransmission Fluid Ford
---
MPM Shift Control Fluid
UFI: E793-83T8-UN4Q-QE9T
MPM ATF Automatic Transmission Fluid MB7
---
MPM DCTF Double Clutch Transmission Fluid
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Grote hoeveelheden: grote productlekkage met zand of aarde indijken.
Beschermende handschoenen van Nitrilrubber (NBR) of Neopreen rubber (HNBR). Permeatie: 5 (> 240 minuten). Dikte: >0,38 mm. Normen: EN 374-2, EN 374-3, EN 388.
Veiligheidsbril met zijbescherming, geschikt voor druppeltjes. Norm: EN 166.
Ademhalingsapparatuur is gewoonlijk niet vereist wanneer er adequate natuurlijke of locale afvoerventilatie is. Bij risico op overmatige damp, nevel of stofdeeltjes een goedgekeurde ademhalingsbescherming gebruiken. Filter type P of vergelijkbare norm voor mist of rook. Combinatiefilter voor deeltjes en organische gassen en dampen (kookpunt >65℃) kan nodig zijn bij aanwezigheid van damp of abnormale geur. Gebruik filter type AP of vergelijkbare norm.
Onder normale gebruiksomstandigheden wordt geen speciale kleding/huidbescherming aanbevolen.
Zie Rubriek 12 en Rubriek 6 voor beperking en controle van de blootstelling van het milieu.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for MPM Automatic Transmission Flush?
The signal word is danger.
What is the physical form of MPM Automatic Transmission Flush?
MPM Automatic Transmission Flush is a vloeibaar appearing as olieachtige vloeistof. with geel. color. It has karakteristiek. odor.
What is the solubility of MPM Automatic Transmission Flush?
Niet oplosbaar in water.
What is MPM Automatic Transmission Flush used for?
Onderhoudsproducten voor de automobielindustrie
What are the hazard statements for MPM Automatic Transmission Flush?
This substance has 1 hazard statement:
- H304: Kan dodelijk zijn als de stof bij inslikken in de luchtwegen terechtkomt.
What is the melting point of MPM Automatic Transmission Flush?
The melting point is Niet beschikbaar and the boiling point is >280 ℃.