NextSDS Logo
FI

FIM-LITE

NO SIGNAL WORD poeder SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
FIM-LITE

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Isolatiemortel die de functie van opvulling, isolatie en onderlaag vervult alvorens de afwerkvloer wordt aangebracht. EPS-korrels met cement als bindmiddel.

Overview

FIM-LITE is a grijs of wit poeder substance commonly used isolatiemortel die de functie van opvulling, isolatie en onderlaag vervult alvorens de afwerkvloer wordt aangebracht. eps-korrels met cement als bindmiddel..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Irriterend
Gevaar voor ernstig oogletsel
Kan overgevoeligheid veroorzaken bij contact met de huid.

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

FIM P&R nv

manufacturer

Nijverheidsstraat 46, 2260 Westerlo, België

BE

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

BE

08.30u - 1

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Portland cement, Cr(VI) < 2 ppm
EC: 266-043-4
65997-15-1 70% Hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Neem de persoon mee naar de frisse lucht. Raadpleeg een arts als de irritatie aanhoudt.

Symptoms:

Irritatie, ongemak, hoest of andere symptomen.

Skin Contact

Als het cement droog is, verwijder het dan en spoel het grondig af met water. Als het cement bedorven is, was dan de huid met veel water. Verwijder besmette kleding, schoenen, horloges en andere voorwerpen en reinig ze grondig voordat u ze opnieuw gebruikt. Raadpleeg een arts als er irritatie of brandwonden optreden.

Symptoms:

Irritatie of brandwonden.

Eye Contact

Wrijf niet om verdere schade aan het hoornvlies te voorkomen. Indien nodig, verwijder de lenzen en spoel onmiddellijk en overvloedig met schoon water. Houd hierbij de oogleden wijd open. Spoel gedurende ten minste 45 minuten om alle achtergebleven deeltjes te verwijderen. Gebruik indien mogelijk isotoon water (0,9% NaCl). Raadpleeg een bedrijfsarts of oogarts.

Symptoms:

Irritatie, mogelijk schade aan het hoornvlies.

Ingestion/Swallowing

Geen braken opwekken. Als de persoon bij bewustzijn is, spoel dan de mond met water en laat de persoon veel water drinken. Neem onmiddellijk contact op met een arts of het antigifcentrum.

Symptoms:

Geen specifieke symptomen vermeld.

Immediate Medical Attention Required

Neem onmiddellijk contact op met een arts of het antigifcentrum.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Evaporation Rate
Not available
Explosive Limits
Not available
Boiling Point
Not available
Appearance
Grijs of wit poeder
Crystallisation Point
Not available
Cloud Point
Not available
Auto Ignition Temperature
Niet van toepassing
Softening Point
Not available
Relative Density
Not available
Upper Explosive Limit
Not available
Kinematic Viscosity
Not available
Vapor Density
Not available
Solubility In Water
Tot 1,5 g/l bij 20℃
Partition Coefficient
Not available
Voc Content
Not available
Dynamic Viscosity
Not available
Form
poeder
Lower Explosive Limit
Not available
Solubility
Not available
Properties Status
Not available
Colour Intensity
Not available
Colour
Grijs of wit
Physical State Data
solid
Solubility In Fat
Not available
Density
2,8 tot 3,2 g/cm3 bij 20℃
Critical Property
Decomposition Temperature
Not available
Molecular Weight
Not available
Ph
Basis tussen 11 en 13,5
Bulk Density
0,9 tot 1,2 g/cm3 bij 20℃
Odor Threshold
Not available
Relative Evaporation Rate
Not available
Metal Corrosion
Not available
Physical State
poeder
Critical Property
Odor
Geurloos
Vapor Pressure
Not available
Solidification Point
Not available
State Under Standard Conditions
Not available
Flammability
Not available
Freezing Point
Not available
Flash Point
Niet van toepassing
Critical Property
Melting Point
> 1000℃
Critical Property
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Draag waterdichte handschoenen met een katoenen voering.

Eye Protection

Draag een veiligheidsbril als er kans is op rondvliegend stof of als er kans is dat er poeder of pasta in de ogen terechtkomt.

Respiratory Protection

Als er cementstof in de lucht aanwezig is, wordt het gebruik van een stofmasker aanbevolen.

Skin/Body Protection

Draag kleding die geschikt is voor het soort werk (overall) en die de onderarmen beschermt in samenhang met de handschoenen. Voor knielend werk worden waterdichte kniebeschermers aanbevolen. Er kunnen "barrière"crèmes worden gebruikt. Het dragen van laarzen (waterdichte schoenen) wordt aanbevolen. Bij contact grondig wassen. Houd werkkleding gescheiden van vrijetijdskleding. Maak ze apart schoon.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for FIM-LITE?

The signal word for this substance is "no signal word".

What is the physical form of FIM-LITE?

FIM-LITE is a poeder appearing as grijs of wit poeder with grijs of wit color. It has geurloos odor.

What is FIM-LITE used for?

Isolatiemortel die de functie van opvulling, isolatie en onderlaag vervult alvorens de afwerkvloer wordt aangebracht. EPS-korrels met cement als bindmiddel.

What is the melting point of FIM-LITE?

The melting point is > 1000℃ .