NextSDS Logo
GR

GRF SPRAY ADHESIVE AE 500ML*12 L221

DANGER Aerosol SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
GRF SPRAY ADHESIVE AE 500ML*12 L221

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Kleefstof
Uses Advised Against
Geen verdere relevante informatie verkrijgbaar.

Overview

GRF SPRAY ADHESIVE AE 500ML*12 L221 commonly used kleefstof.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Aerosol Category 1 H222
Aerosol Category 1 H229
Aquatic Chronic Category 2 H411
Skin Irrit. Category 2 H315
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
  • H229: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
  • H315: Veroorzaakt huidirritatie.
  • H336: Kan slaperigheid of duizeligheid veroorzaken.
  • H411: Giftig voor in het water levende organismen, met langdurige gevolgen.

Precautionary Statements

  • P101: Bij het inwinnen van medisch advies, de verpakking of het etiket ter beschikking houden.
  • P102: Buiten het bereik van kinderen houden.
  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
  • P211: Niet in een open vuur of op andere ontstekingsbronnen spuiten.
  • P251: Ook na gebruik niet doorboren of verbranden.
  • P261: Inademing van spuitnevel vermijden.
  • P273: Voorkom lozing in het milieu.
  • P410+P412: Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 ℃/122 ΒΊF.
  • P501: De inhoud/verpakking afvoeren overeenkomstig de nationale voorschriften.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Bison International

manufacturer

πŸ“

Dr.A.F.Philipsstraat 9, NL-4462 EW Goes, PO Box 160, NL-4460 AD Goes

🌍

NL

πŸ“ž

+31 88 3235700

πŸ“ 

+31 88 3235800

Bison International

manufacturer

πŸ“

Excelsiorlaan 27, B 3, B-1930 Zaventem

🌍

BE

πŸ“ž

+32 3 710 92 92

πŸ“ 

+32 3 710 92 90

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Antigifcentrum

πŸ“ž

070 245245

🌍

BE

Groothertogdom Luxemburg

πŸ“ž

8002 - 5500

🌍

LU

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Kleefstof

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
DIMETHYL ETHER
EC: 204-065-8
115-10-6 25-50% ⚠️ Hazardous
Hydrocarbons, C6, isoalkanes, < 5% n-hexane
EC: 931-254-9
64742-49-0 25-50% ⚠️ Hazardous
nafta (aardolie), met waterstof behandeld licht
EC: 926-605-8
64742-49-0 10-25% ⚠️ Hazardous
nhexaan
EC: 203-777-6
110-54-3 1-2.5% ⚠️ Hazardous
Cyclohexane stof waarvoor binnen de Gemeenschap een blootstellingsgrens op de werkvloer geldt
EC: 203-806-2
110-82-7 0.25-1% ⚠️ Hazardous
phenol, 4-methyl-, reaction products with dicyclopentadiene and isobutylene
EC: 271-867-2
68610-51-5 1% ⚠️ Hazardous

Additional Information

De woordelijke inhoud van de opgegeven aanwijzingen inzake de mogelijke gevaren is te vinden in hoofdstuk 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Bij bewusteloosheid ligging en vervoer in stabiele zijligging.

πŸ–οΈ Skin Contact

Onmiddellijk met water en zeep afwassen en goed naspoelen.

πŸ‘οΈ Eye Contact

Ogen bij geopend ooglid meerdere minuten met stromend water spoelen.

🍽️ Ingestion/Swallowing

Als de klachten niet minderen, een arts raadplegen.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧊 Melting Point
Niet bepaald.
Critical Property
πŸ“Š Solubility In Fat
Not available
πŸ“Š Dynamic Viscosity
Niet bepaald.
πŸ’¨ Vapor Pressure
5200 hPa
πŸ“Š Solubility In Water
Niet resp. gering mengbaar.
πŸ“Š Explosive Limits
Not available
πŸ“Š Voc Content
89,43 %
πŸ“Š Colour Intensity
Not available
πŸ“Š Form
Aerosol
πŸ“Š Relative Density
Niet bepaald.
πŸ“Š Vapor Density
Niet bepaald.
πŸ“Š Kinematic Viscosity
Niet bepaald.
πŸ“Š Relative Evaporation Rate
Not available
πŸ“Š Molecular Weight
Not available
πŸ“Š Properties Status
Not available
πŸ‘οΈ Appearance
Not available
πŸ”₯ Flash Point
-42 ℃
Critical Property
βš–οΈ Density
~0,773 g/cm3
Critical Property
πŸ§ͺ Physical State
Aerosol
Critical Property
🎨 Colour
Volgens de produktbeschrijving
πŸ§ͺ Ph
Niet bepaald.
πŸ“Š Physical State Data
aerosol
πŸ“Š Auto Ignition Temperature
235 ℃
πŸ’¨ Boiling Point
60 ℃
Critical Property
πŸ“Š Softening Point
Not available
πŸ“Š Cloud Point
Not available
πŸ“Š Partition Coefficient
Niet bepaald.
πŸ“Š State Under Standard Conditions
Not available
πŸ“Š Freezing Point
Niet bepaald.
πŸ“Š Crystallisation Point
Not available
πŸ“Š Upper Explosive Limit
18,6 Vol %
πŸ‘ƒ Odor
Karakteristiek
πŸ’§ Solubility
Not available
πŸ’¨ Evaporation Rate
Niet bruikbaar.
πŸ“Š Odor Threshold
Niet bepaald.
πŸ“Š Bulk Density
Not available
πŸ“Š Metal Corrosion
Niet van toepassing
πŸ“Š Decomposition Temperature
Niet bepaald.
πŸ“Š Lower Explosive Limit
0,7 Vol %
πŸ“Š Solidification Point
Not available
πŸ”₯ Flammability
Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Geen aanvullende gegevens. Zie 7.

🧀 Hand Protection

Veiligheidshandschoenen. Het handschoenmateriaal moet ondoorlatend en bestand zijn tegen het product / de stof / de bereiding. Kies handschoenmateriaal rekening houdend met de penetratietijden, de permeatiegraden en de degradatie. Aanbevolen materiaaldikte : > 0,12 mm. Nitrilrubber. Voor het mengsel van de hieronder vermelde chemicalien moet de penetratietijd minstens 10 minuten bedragen (permeatie volgens EN 374 Deel 3: Level 1).

πŸ‘οΈ Eye Protection

Niet noodzakelijk.

😷 Respiratory Protection

Bij onvoldoende ventilatie ademhalingsbescherming. Aanbevolen filter voor kortstondig gebruik: Filter A

🦺 Skin/Body Protection

Draag geschikte beschermende kleding

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN1950

πŸ“¦ Proper Shipping Name

AEROSOLS, flammable

⚠️ Transport Hazard Class

2

πŸ“‹ Packing Group

Niet van toepassing

πŸš› ADR Transport Precautions

Waarschuwing: Gassen - F-D,S-U

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for GRF SPRAY ADHESIVE AE 500ML*12 L221?

The signal word for this substance is "danger".

What is the physical form of GRF SPRAY ADHESIVE AE 500ML*12 L221?

GRF SPRAY ADHESIVE AE 500ML*12 L221 is a aerosol with volgens de produktbeschrijving color. It has karakteristiek odor.

What is GRF SPRAY ADHESIVE AE 500ML*12 L221 used for?

Kleefstof

What are the hazard statements for GRF SPRAY ADHESIVE AE 500ML*12 L221?

This substance has 5 hazard statements: H222: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting. H229: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting. H315: Veroorzaakt huidirritatie. H336: Kan slaperigheid of duizeligheid veroorzaken. H411: Giftig voor in het water levende organismen, met langdurige gevolgen.

What is the melting point of GRF SPRAY ADHESIVE AE 500ML*12 L221?

The melting point is Niet bepaald. and the boiling point is 60 ℃.