01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
3-36
Product Form
Spuitbus

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Smeermiddelen

Manufacturers & Suppliers

C

CRC Industries Europe bvba

manufacturer

Touwslagerstraat 1 9240 Zele Belgium

C

CRC Industries Finland Oy

national supplier

Laurinkatu 57 A 23 B, 08100 Lohja

+358/(19)32.921

C

CRC Industries France

national supplier

6, avenue du marais, C.S. 90028, 95102 Argenteuil Cedex

01.34.11.20.00

C

CRC Industries Deutschland GmbH

national supplier

Südring 9, D-76473 Iffezheim

(07229) 303 0

C

CRC INDUSTRIES IBERIA S.L.U.

national supplier

GREMIO DEL CUERO-PARC.96, POLIGONO INDUSTR. DE HONTORIA, 40195 SEGOVIA

0034/921.427.546

C

CRC Industries Sweden

national supplier

Laxfiskevägen 16, 433 38 Partille

0046/31 706 84 80

Emergency Contacts

CRC Industries Europe

+32(0)52/45.60.11

(kantooruren)

Nationaal vergiftigingen informatie centrum

030 274 88 88

Antigifcentrum

070 - 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Aerosol Cat. 2

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H223 Ontvlambare aerosol.
H229 Houder onder druk: kan openbarsten bij verhitting.

Precautionary Statements

P102 Buiten het bereik van kinderen houden.
P210 Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
P211 Niet in een open vuur of op andere ontstekingsbronnen spuiten.
P251 Ook na gebruik niet doorboren of verbranden.
Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50℃/122ºF.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mengsels
Chemical Name CAS Number Concentration Hazardous
Koolwaterstoffen, C11-14, n-alkanen, isoalkanene, cyclische, < 2% aromaten EC: 926-141-6 --- 50 - 75% Yes
minerale olie (IP 346 DMSO extract < 3%) --- 10 - 25% No
koolstofdioxide EC: 204-696-9 124-38-9 1 - 5% Yes
sulfonic acids, petroleum, sodium salts EC: 271-781-5 68608-26-4 1 - 5% Yes

Notes

A : stoffen waarvoor in de Gemeenschap grenzen voor de blootstelling op het werk zijn vastgesteld B : stoffen waarvoor nationale grenzen voor de blootstelling op het werk zijn vastgesteld G : uitgezonderd voor registratieverplichting volgens art.2(7)van de REACH verordening Nr 1907/2006 Q : Het CAS-no is indicatief en kan gebruikt voor de stof identificatie buiten de EU en voor ingave in universele databanken.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

NA INADEMING: de persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen. Bij onwel voelen een ANTIGIFCENTRUM of een arts raadplegen.

Symptoms: Overmatige inademing van dampen van oplosmiddel kan misselijkheid, hoofdpijn en duizeligheid veroorzaken

Skin contact

Met veel water en zeep wassen. Bij huidirritatie: een arts raadplegen.

Symptoms: Kan irritatie veroorzaken. Symptomen : roodheid en pijn

Eye contact

Als de stof in de ogen komt, onmiddellijk met veel water uitspoelen Bij aanhoudende oogirritatie: een arts raadplegen.

Symptoms: Kan irritatie veroorzaken. Symptomen : roodheid en pijn

Ingestion

Bij inslikken niet laten braken vanwege het risico van inademing in de longen. Als u vermoedt dat dit gebeurd is, onmiddellijk een arts raadplegen.

Symptoms: Bij inname gevaar voor chemische pneumonie Symptomen : pijnlijke keel, buikpijn, misselijkheid, braken

Immediate Medical Attention

Bij aanhoudende oogirritatie: een arts raadplegen. Bij huidirritatie: een arts raadplegen. Bij onwel voelen een ANTIGIFCENTRUM of een arts raadplegen. Als u vermoedt dat dit gebeurd is, onmiddellijk een arts raadplegen. Indien men zich onwel voelt een arts raadplegen (indien mogelijk hem dit etiket tonen) Bij blijvende symptomen steeds dokter raadplegen

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Voor voldoende ventilatie zorgen Uit de buurt van warmte en van ontstekingsbronnen houden Maatregelen treffen tegen ontladingen van statische elektriciteit

Hands

Afhankelijk van de hoeveelheid en de tijd en het risico op contact met het product, kan de producent van de beschemende handschoenen advies geven bij de selectie van het juiste type materiaal en de doorbraaktijd van de handschoenen. Aanbevolen handschoenen: Nitril

Eyes

Draag een nauwaansluitende veiligheidsbril volgens norm EN 166.

Respiratory

Bij ontoereikende ventilatie een geschikt ademhalingsbeschuttingsmiddel dragen. Aanbevolen ademhalingsbescherming: Luchtzuiverend organisch gas/dampmasker (type A)

Environmental

Voorkom lozing in het milieu. Gelekte/gemorste stof opruimen.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solidification Point
---
Softening Point
---
Molecular Weight
---
Lower Explosive Limit
Niet gekend.
Auto Ignition Temperature
> 200 °℃
Solubility In Water
Emulgeert met water
Bulk Density
---
Kinematic Viscosity
---
Upper Explosive Limit
Niet gekend.
Colour
Blauw-groen.
Physical State
Vloeistof in spuitbus met CO2 drijfgas.
Dynamic Viscosity
3.9 mPa.s (@ 20℃).
Odor
Karakteristieke geur.
Metal Corrosion
---
Odor Threshold
---
Vapor Pressure
Niet gekend.
Relative Density
0.83 g/cm3 (@ 20℃).
Density
---
Boiling Point
190-250 ℃
Freezing Point
---
Solubility
---
Partition Coefficient
---
Properties Status
---
Colour Intensity
---
Melting Point
---
Decomposition Temperature
---
Voc Content
545 g/l
Solubility In Fat
---
Ph
Niet van toepassing.
Form
---
Evaporation Rate
Niet gekend.
Flash Point
78 °℃ (Gesloten Kop)
Relative Evaporation Rate
Niet gekend.
Vapor Density
---
Explosive Limits
---
Crystallisation Point
---
Appearance
Vloeistof in spuitbus met CO2 drijfgas.
Flammability
---
Physical State Data
liquid
State Under Standard Conditions
---
Cloud Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
SPUITBUSSEN (AEROSOLEN)
Transport Class
2.1
Packing Group
Niet van toepassing.
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for 3-36?

The signal word is warning.

What is the physical form of 3-36?

3-36 is a vloeistof in spuitbus met co2 drijfgas. appearing as vloeistof in spuitbus met co2 drijfgas. with blauw-groen. color. It has karakteristieke geur. odor.

What is 3-36 used for?

Smeermiddelen

What are the hazard statements for 3-36?

This substance has 2 hazard statements:

  • H223: Ontvlambare aerosol.
  • H229: Houder onder druk: kan openbarsten bij verhitting.