NextSDS Logo
RA

RADIASURF 7905

Vast SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
RADIASURF 7905
Product Form
Stof (UVCB)
Chemical Name
Glycerides, C16-18 (even numbered) mono-

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

REACH Registration Number
01-2119492308-31

Registration, Evaluation, Authorisation and Restriction of Chemicals - EU regulation compliance

Uses Information

Identified Uses
General overview of industrial uses of glycerol fatty esters; General overview of professional uses of glycerol fatty esters; General overview of consumer uses of glycerol fatty esters
Uses Advised Against
Geen aanvullende informatie beschikbaar

Overview

RADIASURF 7905 (CAS: 91052-47-0 ) is a vaste stof in diverse vormen. substance commonly used general overview of industrial uses of glycerol fatty esters; general overview of professional uses of glycerol fatty esters; general overview of consumer uses of glycerol fatty esters.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

N/A

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

OLEON N.V. company logo - Safety Data Sheet supplier organization

OLEON N.V.

manufacturer

📍

Assenedestraat 2 9940 Ertvelde - Belgium

🌍

BE

📞

+32 9 341 10 11

📠

+32 9 341 10 00

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

SGS ERS

📞

+32 3 575 55 55

🌍

BE

🕒

24/7

💡

wereldwijd; Oleon contract nr. 76858

SGS ERS

📞

+1 888 765 6554

🌍

US

🕒

24/7

💡

USA gratis; Oleon contract nr. 76858

Centre Anti- Poisons/Antigifcentrum c/o Hôpital Central de la Base - Reine Astrid

📞

+32 70 245 245

🌍

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

UVCB

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Glycerides, C16-18 (even numbered) mono-
EC: 293-208-8
91052-47-0 100% ✓ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Breng het slachtoffer in de frisse lucht. Bij ademhalingsproblemen: arts/medische dienst raadplegen.

🖐️ Skin Contact

Spoelen met water. Gebruik van zeep toegestaan. Slachtoffer naar arts brengen als irritatie aanhoudt.

👁️ Eye Contact

Spoelen met water. Slachtoffer naar oogarts brengen als irritatie aanhoudt.

🍽️ Ingestion/Swallowing

Mond spoelen met water. Antigifcentrum raadplegen (www.who.int/ipcs/poisons/centre/directory/en). Indien men zich onwel voelt: medische dienst/arts raadplegen.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Vast
Critical Property
📊 Physical State Data
solid
📊 State Under Standard Conditions
Vast
👁️ Appearance
Vaste stof in diverse vormen.
🎨 Colour
Wit tot licht geel.
📊 Colour Intensity
Not available
📊 Form
Not available
👃 Odor
Kenmerkende geur. Bijna reukloos.
📊 Odor Threshold
Geen gegevens beschikbaar
🧪 Ph
5-8
🧊 Melting Point
~ 65 °℃
Critical Property
💨 Boiling Point
> 250 °℃
Critical Property
🔥 Flash Point
~ 220 °C (ASTM D92)
Critical Property
📊 Freezing Point
Geen gegevens beschikbaar
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Geen gegevens beschikbaar
💨 Evaporation Rate
Not available
💨 Vapor Pressure
< 0.01 hPa (20℃)
📊 Vapor Density
Not available
📊 Relative Density
Geen gegevens beschikbaar
📊 Bulk Density
Not available
⚖️ Density
ca. 0.95
Critical Property
🔥 Flammability
Geen gegevens beschikbaar
📊 Upper Explosive Limit
Not available
📊 Lower Explosive Limit
Not available
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
> 300 °℃
📊 Decomposition Temperature
> Vlampunt
💧 Solubility
Geen gegevens beschikbaar
📊 Partition Coefficient
> 5 (estimated)
📊 Solubility In Water
Niet oplosbaar in water.
📊 Solubility In Fat
Oplosbaar in oliën/vetten.
📊 Molecular Weight
Not available
📊 Voc Content
< 0.1 % (1999/13/EC; 2004/42/EC; 2010/75/EU; SR 814.018)
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
30 - 40 cP (75℃)
📊 Kinematic Viscosity
~ 32 mm2/s (80°℃)
📊 Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🧤 Hand Protection

Gloves. Nitrile rubber (good resistance).

👁️ Eye Protection

In case of dust generation: protective glasses.

😷 Respiratory Protection

In case of dust generation: dust mask with filter type P2.

🦺 Skin/Body Protection

Protective clothing. Nitrile rubber (good resistance).

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the physical form of RADIASURF 7905?

RADIASURF 7905 is a vast appearing as vaste stof in diverse vormen. with wit tot licht geel. color. It has kenmerkende geur. bijna reukloos. odor.

What is the solubility of RADIASURF 7905?

Geen gegevens beschikbaar

What is RADIASURF 7905 used for?

General overview of industrial uses of glycerol fatty esters; General overview of professional uses of glycerol fatty esters; General overview of consumer uses of glycerol fatty esters

What is the melting point of RADIASURF 7905?

The melting point is ~ 65 °℃ and the boiling point is > 250 °℃.