NextSDS Logo
Ci

Citric Acid Cleaning Solution

NO SIGNAL WORD Vloeistof SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Citric Acid Cleaning Solution
Product Code
STD 77910-01

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Analytisch reagens
Uses Advised Against
Niet bekend.

Overview

Citric Acid Cleaning Solution commonly used analytisch reagens.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Geen.)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Veolia WTS Analytical Instruments, Inc.

manufacturer

6060 Spine Road Boulder, CO 80301

US

303-444-2009

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

INFOTRAC

1-800-535-5053

US

Noord-Amerika

INFOTRAC

1-352-323-3500

US

24/7

Outside of N.A., call collect

Veolia

(800) 877-1940

US

ANTIGIFCENTRUM

+ 32 70 245 245

BE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
WATER
EC: 231-791-2
7732-18-5 99.945% Non-hazardous
citroenzuur, watervrij
EC: 201-069-1
77-92-9 0.055% Hazardous

Composition Notes

Alle concentraties worden uitgedrukt in massaprocent, tenzij het een gas betreft. Gasconcentraties worden uitgedrukt in volumeprocent.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

In de frisse lucht plaatsen.

Skin Contact

Met zeep en water wassen.

Eye Contact

Met water afspoelen.

Ingestion/Swallowing

De mond spoelen.

Immediate Medical Attention Required

Symptomatisch behandelen.

Medical Treatment

Symptomatisch behandelen.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Vloeistof
Critical Property
Physical State Data
liquid
State Under Standard Conditions
Not available
Appearance
Not available
Colour
Kleurloos
Colour Intensity
Not available
Form
vloeibaar
Odor
Citrus
Odor Threshold
Not available
Ph
3
Melting Point
Niet beschikbaar
Critical Property
Boiling Point
Niet beschikbaar
Critical Property
Flash Point
- 93 C P-M(CC)
Critical Property
Freezing Point
Niet beschikbaar
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Trager dan ether
Evaporation Rate
Not available
Vapor Pressure
18 mmHg
Vapor Density
Not available
Relative Density
1
Bulk Density
Not available
Density
Not available
Flammability
Niet van toepassing.
Upper Explosive Limit
Niet beschikbaar
Lower Explosive Limit
Niet beschikbaar
Explosive Limits
Not available
Auto Ignition Temperature
Niet beschikbaar
Decomposition Temperature
Niet beschikbaar
Solubility
Not available
Partition Coefficient
Niet beschikbaar
Solubility In Water
100 %
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
Not available
Kinematic Viscosity
Niet beschikbaar
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Er moet een goede algehele ventilatie worden gebruikt. Ventiliatiesnelheden moeten zijn aangepast aan de omstandigheden. Gebruik, indien van toepassing, afgesloten procesruimten, plaatselijke afzuiging of andere technische middelen om de concentraties in de lucht onder de aanbevolen blootstellingslimieten te houden. Wanneer er geen blootstellingslimieten zijn vastgesteld, houd dan de concentraties in de lucht op een aanvaardbaar niveau.

Hand Protection

Toepasselijke chemisch-resistente handschoenen dragen. Veiligheidshandschoenen (plastic, ondoordringbaar) (Bescherming tegen kortstondig contact) Laagdikte: 0.5 mm Penetratietijd: > 480 min CEN : EN 420

Eye Protection

Draag een veiligheidsbril met zij-afscherming (of een veiligheidsbril die geheel op het gezicht aansluit). CEN : EN 166

Respiratory Protection

Bij ontoereikende ventilatie een geschikte adembescherming dragen.

Skin/Body Protection

Draag geschikte beschermende kleding. CEN : EN ISO 13688

Environmental Exposure Controls

Emissies van ventilatie- of procesapparatuur moet worden gecontroleerd om na te gaan dat zij voldoen aan de vereisten van milieubeschermingswetten. Rookgaswassers, filters of technische aanpassingen aan de procesapparatuur kunnen nodig zijn om de emissies tot aanvaardbaar niveaus te brengen.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Citric Acid Cleaning Solution?

The signal word for this substance is "no signal word".

What is the physical form of Citric Acid Cleaning Solution?

Citric Acid Cleaning Solution is a vloeistof with kleurloos color. It has citrus odor.

What is Citric Acid Cleaning Solution used for?

Analytisch reagens

What is the melting point of Citric Acid Cleaning Solution?

The melting point is Niet beschikbaar and the boiling point is Niet beschikbaar.