NextSDS Logo
CU

CUSTOM CLEAN CC49

NO SIGNAL WORD Vloeistof. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
CUSTOM CLEAN CC49

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Reiniger
Uses Advised Against
Niet bekend.

Overview

CUSTOM CLEAN CC49 commonly used reiniger.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Geen)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Veolia Water Technologies & Solutions Belgium BV

distributor

๐Ÿ“

Toekomstlaan 54 Industriepark Wolfstee 2200 HERENTALS

๐ŸŒ

BE

๐Ÿ“ž

+32 14 / 25 91 11

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+44(0)1235 239670

๐ŸŒ

GB

๐Ÿ•’

24/7

๐Ÿ—ฃ๏ธ

Languages: EN

๐Ÿ’ก

Europa, Midden-Oosten, Afrika, Isral

SUEZWATERTECH29003-NCEC

๐Ÿ“ž

+44(0)1235 239671

๐ŸŒ

GB

๐Ÿ—ฃ๏ธ

Languages: AR

๐Ÿ’ก

Middle East & Africa

ANTIGIFCENTRUM

๐Ÿ“ž

+ 32 70 245 245

๐ŸŒ

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mengsel

General Composition

Mengsel van essentile olin

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Vloeistof.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Wit
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
vloeibaar
๐Ÿ‘ƒ Odor
Aromatisch
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
6,9 Neat
๐ŸงŠ Melting Point
< -15 C
Critical Property
๐Ÿ’จ Boiling Point
Niet beschikbaar
Critical Property
๐Ÿ”ฅ Flash Point
Niet beschikbaar
Critical Property
๐Ÿ“Š Freezing Point
< -15 C
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Trager dan ether
๐Ÿ’จ Vapor Pressure
18 mmHg
๐Ÿ“Š Vapor Density
< 1
๐Ÿ“Š Relative Density
0,99
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Niet van toepassing.
๐Ÿ“Š Upper Explosive Limit
Niet beschikbaar
๐Ÿ“Š Lower Explosive Limit
Niet beschikbaar
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Niet beschikbaar
๐Ÿ“Š Decomposition Temperature
Niet beschikbaar
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Niet beschikbaar
๐Ÿ“Š Solubility In Water
100 %
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
0 % geschat
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Niet beschikbaar
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Er moet een goede algehele ventilatie worden gebruikt. Ventiliatiesnelheden moeten zijn aangepast aan de omstandigheden. Gebruik, indien van toepassing, afgesloten procesruimten, plaatselijke afzuiging of andere technische middelen om de concentraties in de lucht onder de aanbevolen blootstellingslimieten te houden. Wanneer er geen blootstellingslimieten zijn vastgesteld, houd dan de concentraties in de lucht op een aanvaardbaar niveau.

๐Ÿงค Hand Protection

Toepasselijke chemisch-resistente handschoenen dragen. Geschikte handschoenen kunnen aanbevolen worden door de handschoenenleverancier. Veiligheidshandschoenen (plastic, ondoordringbaar) (Bescherming tegen kortstondig contact) Laagdikte: 0.5 mm Penetratietijd: > 480 min CEN : EN 420

๐Ÿ‘๏ธ Eye Protection

Draag een veiligheidsbril met zij-afscherming (of een veiligheidsbril die geheel op het gezicht aansluit). CEN : EN 166

๐Ÿ˜ท Respiratory Protection

Geen persoonlijke adembescherming vereist bij normaal gebruik.

๐Ÿฆบ Skin/Body Protection

Draag geschikte beschermende kleding. CEN : EN ISO 13688

๐ŸŒ Environmental Exposure Controls

Emissies van ventilatie- of procesapparatuur moet worden gecontroleerd om na te gaan dat zij voldoen aan de vereisten van milieubeschermingswetten. Rookgaswassers, filters of technische aanpassingen aan de procesapparatuur kunnen nodig zijn om de emissies tot aanvaardbaar niveaus te brengen.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for CUSTOM CLEAN CC49?

The signal word for this substance is "no signal word".

What is the physical form of CUSTOM CLEAN CC49?

CUSTOM CLEAN CC49 is a vloeistof. with wit color. It has aromatisch odor.

What is CUSTOM CLEAN CC49 used for?

Reiniger

What is the melting point of CUSTOM CLEAN CC49?

The melting point is < -15 C and the boiling point is Niet beschikbaar.