NextSDS Logo
Safety Data Sheet NL

PU-SYSTEM FLEXOVOSS K6S (A-Komponente)

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PU-SYSTEM FLEXOVOSS K6S (A-Komponente)
Product Code
126.447

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Coatings

Manufacturers & Suppliers

V

Vosschemie GmbH

manufacturer

Esinger Steinweg 50, 25436 Uetersen, Duitsland

04122 717 0

V

VOSSCHEMIE

Emergency Contacts

Giftinformationszentrum (GIZ)-Nord, Göttingen, Deutschland

0551 19240

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mengsel

Chemical Name CAS Number Concentration Hazardous
1-phenoxypropan-2-ol EC: 212-222-7 770-35-4 1 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Het slachtoffer overbrengen in de frisse lucht. Als de verschijnselen aanhouden medische hulp inroepen.

Skin contact

Onmiddellijk afwassen met zeep en veel water en alle verontreinigde kleding en schoenen uittrekken. Indien symptomen aanhouden, een arts raadplegen.

Eye contact

Oogleden open houden en de ogen spoelen met veel water gedurende tenminste 15 minuten. Medische hulp inroepen.

Ingestion

GEEN braken opwekken. Onmiddellijk een arts waarschuwen.

Immediate Medical Attention

Medische hulp inroepen indien symptomen aanhouden (inademing, huidcontact) of voor oogcontact. Onmiddellijk een arts waarschuwen bij inslikken.

Medical Treatment

Symptomatisch behandelen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

This can be achieved by good general extraction or, where practically feasible, local exhaust ventilation.

Hands

Material: Nitrile rubber, Breakthrough time: >= 480 min, Glove thickness: >= 0.4 mm, Standard: DIN EN 374, Protection index: Class 6. Gloves must be discarded and replaced upon signs of degradation or chemical breakthrough. Data on permeation time/material strength are standard values! The actual permeation time/material strength must be requested from the manufacturer of the protective gloves. The choice of a suitable glove depends not only on the material but also on other quality aspects and varies from manufacturer to manufacturer. Preventive skin protection.

Eyes

Safety glasses with side shields according to EN 166.

Respiratory

No personal respiratory protection required under normal use.

Skin/Body

Wear suitable protective clothing, e.g., made of cotton or heat-resistant synthetic fibers. Long-sleeved clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor
licht, kenmerkend
Vapor Pressure
< 100 hPa (50 C)
Kinematic Viscosity
Niet uitgevoerd
Dynamic Viscosity
---
Ph
Niet uitgevoerd
Cloud Point
---
State Under Standard Conditions
---
Solubility
---
Form
---
Solubility In Water
niet mengbaar
Crystallisation Point
---
Density
circa 1,5 g/cm3 (20 C)
Explosive Limits
---
Softening Point
---
Colour Intensity
---
Upper Explosive Limit
---
Metal Corrosion
---
Flash Point
- 100 C
Partition Coefficient
Geen gegevens beschikbaar
Flammability
---
Melting Point
Niet uitgevoerd
Voc Content
---
Solubility In Fat
---
Evaporation Rate
---
Properties Status
---
Relative Density
---
Appearance
visceuze vloeistof
Auto Ignition Temperature
- 350 C
Physical State Data
liquid
Boiling Point
Niet uitgevoerd
Lower Explosive Limit
---
Physical State
visceuze vloeistof
Decomposition Temperature
---
Vapor Density
---
Molecular Weight
---
Solidification Point
---
Odor Threshold
---
Colour
grijs
Bulk Density
---
Relative Evaporation Rate
---
Freezing Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Niet gereguleerd als gevaarlijke stof
Shipping Name
Niet gereguleerd als gevaarlijke stof
Transport Class
Niet gereguleerd als gevaarlijke stof
Packing Group
Niet gereguleerd als gevaarlijke stof
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PU-SYSTEM FLEXOVOSS K6S (A-Komponente)?

The signal word is no signal word.

What is the physical form of PU-SYSTEM FLEXOVOSS K6S (A-Komponente)?

PU-SYSTEM FLEXOVOSS K6S (A-Komponente) is a visceuze vloeistof appearing as visceuze vloeistof with grijs color. It has licht, kenmerkend odor.

What is PU-SYSTEM FLEXOVOSS K6S (A-Komponente) used for?

Coatings

What is the melting point of PU-SYSTEM FLEXOVOSS K6S (A-Komponente)?

The melting point is Niet uitgevoerd and the boiling point is Niet uitgevoerd.