NextSDS Logo
Safety Data Sheet NL

Suma Frit D9.1

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Suma Frit D9.1

Regulatory Identifiers

CAS Number
N/A
UFI Code
33D4-00K8-2009-5G31

Identified Uses

Friteusereiniger. Afvoerreiniger. Alleen voor professioneel gebruik.

Uses advised against

Gebruik, anders dan het geïdentificeerd gebruik, wordt niet aanbevolen.

Manufacturers & Suppliers

D

Diversey Europe Operations BV

manufacturer

Maarssenbroeksedijk 2, 3542DN Utrecht, The Netherlands

D

Diversey België

distributor

Haachtsesteenweg 672, 1910 Kampenhout, België

016-617777

Emergency Contacts

Antigifcentrum

070-245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Corr. Cat. 1A H314
Eye Dam. Cat. 1 H318

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H314 Veroorzaakt ernstige brandwonden en oogletsel.

Precautionary Statements

P260 Stof niet inademen.
P280 Beschermende handschoenen, beschermende kleding en oog- of gelaatsbescherming dragen.
P303 + P361 + P353 BIJ CONTACT MET DE HUID (of het haar): verontreinigde kleding onmiddellijk uittrekken. Huid met water afspoelen of afdouchen.
P305 + P351 + P338 BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
P310 Onmiddellijk een ANTIGIFCENTRUM (B) of een arts (NL) raadplegen.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mengsel
Chemical Name CAS Number Concentration Hazardous
natriumcarbonaat EC: 207-838-8 497-19-8 30 - 50% No
natriumhydroxide EC: 215-185-5 1310-73-2 10 - 20% No
dinatriummetasilicaat EC: 229-912-9 6834-92-0 10 - 20% No
natriumalkylbenzeensulfonaat EC: 270-115-0 68411-30-3 1 - 3% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

De persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen. Onmiddellijk een ANTIGIFCENTRUM (B) of een arts (NL) raadplegen.

Symptoms: Bijtend voor de luchtwegen.

Skin contact

Was de huid met lauw, zacht stromend water gedurende minstens 30 minuten. Verontreinigde kleding onmiddellijk uittrekken en wassen alvorens deze opnieuw te gebruiken. Onmiddellijk een ANTIGIFCENTRUM (B) of een arts (NL) raadplegen.

Symptoms: Veroorzaakt ernstige brandwonden.

Eye contact

Oogleden open houden en ogen spoelen met veel lauw water, gedurende minstens 15 minuten. Contactlenzen verwijderen, indien mogelijk. Blijven spoelen. Onmiddellijk een ANTIGIFCENTRUM (B) of een arts (NL) raadplegen.

Symptoms: Veroorzaakt ernstige of blijvende schade.

Ingestion

De mond spoelen. Drink onmiddellijk 1 glas water. Bij een bewusteloos persoon nooit iets via de mond toedienen. GEEN braken opwekken. Rustig houden. Onmiddellijk een ANTIGIFCENTRUM (B) of een arts (NL) raadplegen.

Symptoms: Bij het slikken sterk bijtende effecten in de mondholte en de keel, bovendien gevaar voor perforatie van de slokdarm en de maag.

Immediate Medical Attention

Bij bewusteloosheid medische hulp inroepen. Bij onregelmatige ademhaling of ademstilstand kunstmatige beademing toepassen. Onmiddellijk een ANTIGIFCENTRUM (B) of een arts (NL) raadplegen voor alle blootstellingsroutes.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

If the product is diluted using specific dosing systems without risk of splashing or direct skin contact, the personal protective equipment as described in this section is not required. Where possible: use in automated / closed systems and cover open containers. Transfer by pipelines. Fill with automatic systems. Use aids when manually handling the product.

Hands

For undiluted product: Chemical-resistant protective gloves (EN 374). Check the instructions regarding permeability and breakthrough time, as given by the glove supplier. Take into account specific local conditions of use, such as risk of splashing, cutting, contact time and temperature. Suggested gloves for prolonged contact: Material: butyl rubber Breakthrough time: 480 min Material thickness: 0.7 mm. Suggested gloves for splash protection: Material: nitrile rubber Breakthrough time: 30 min Material thickness: 0.4 mm. In consultation with the supplier of protective gloves, another type providing similar protection may be chosen. For diluted product: Wash and dry hands after use. For prolonged contact, skin protection may be required. Repeated or prolonged contact: Chemical-resistant protective gloves (EN 374).

Eyes

(close-fitting) Safety glasses (EN 166).

Respiratory

If exposure to dust cannot be avoided, use: half mask (RN 140) with particle filter P2 (EN 143) or full face mask (EN 136) with particle filter P1 (EN 143). Take into account specific local conditions of use. In consultation with the supplier of respiratory protective equipment, another type providing similar protection may be chosen.

Skin/Body

For normal use, no special measures are required. Wear chemical-resistant clothing and boots if direct skin exposure and/or splashing may occur (EN ISO 13982-1).

Environmental

Must not be discharged undiluted or unneutralized into surface water or drainage channels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Upper Explosive Limit
Niet bepaald
Appearance
Poeder
Density
---
Softening Point
---
Melting Point
Niet bepaald
Partition Coefficient
zie subrubriek 12.3
Relative Evaporation Rate
---
Freezing Point
Niet bepaald
Dynamic Viscosity
---
Flammability
Niet bepaald
Ph
11 (5 %)
Kinematic Viscosity
Niet uitgevoerd
Molecular Weight
---
Solidification Point
---
Decomposition Temperature
Niet van toepassing.
State Under Standard Conditions
---
Solubility
Oplosbaar
Odor
Product specifiek
Odor Threshold
Niet van toepassing
Voc Content
---
Explosive Limits
---
Crystallisation Point
---
Vapor Pressure
Niet bepaald
Relative Density
1.00 (20 C)
Form
Poeder
Evaporation Rate
---
Lower Explosive Limit
Niet bepaald
Metal Corrosion
Niet bepaald
Boiling Point
Niet bepaald
Solubility In Water
Oplosbaar
Physical State
Vaste stof
Physical State Data
solid
Properties Status
---
Cloud Point
---
Colour Intensity
---
Auto Ignition Temperature
Niet bepaald
Solubility In Fat
---
Vapor Density
---
Flash Point
Niet van toepassing.
Bulk Density
---
Colour
Wit
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1823
Shipping Name
Sodium hydroxide, solid, mixture
Transport Class
8
Packing Group
II
ADR

Niets bekend.

IMDG

Niets bekend.

IATA

Niets bekend.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Suma Frit D9.1?

The signal word is danger.

What is the physical form of Suma Frit D9.1?

Suma Frit D9.1 is a vaste stof appearing as poeder with wit color. It has product specifiek odor.

What is the solubility of Suma Frit D9.1?

Oplosbaar

What is Suma Frit D9.1 used for?

Friteusereiniger. Afvoerreiniger. Alleen voor professioneel gebruik.

What are the hazard statements for Suma Frit D9.1?

This substance has 1 hazard statement:

  • H314: Veroorzaakt ernstige brandwonden en oogletsel.

What is the melting point of Suma Frit D9.1?